Anleitung Zusammenfassung


Squeeze the Trigger (39). The tool should not cycle (fire). If it cycles (fires), stop immediately and take the tool to a qualified service technician. 8. Depress the Safety (52) against the workpiece and squeeze the Trigger (39). The tool must cycle (fire) once only. Release the trigger and squeeze it again. The tool must cycle (fire) once only. REV 10a With the Trigger held, carefully lift the nailer and press it against the workpiece again. The tool must not cycle (fire). If it fails to act in the manner explained in bold, have it repaired by a qualified service technician. Loading Staples ALWAYS WEAR ANSI APPROVED IMPACT SAFETY GOGGLES WHEN RELOADING OR DOING ANY OTHER MAINTENANCE ON THIS TOOL. Other people in the work area must also wear ANSI approved impact safety goggles. Warning! Make sure the Stapler is not attached to the air hose whenever loading the tool. 1. Release the Latch (69) and pull back on Magazine B (61). 2. Insert a row of clean, undamaged staples with the crowns up. 3. Push Magazine B (61) forward until the Latch (69) snaps into place. Operating the Stapler 1. Attach the Stapler to the air supply at the Air Plug (82). Start your compressor and check the pressure, making sure it is set at the recommended 60-100 PSI and not to go over the maximum 100 PSI. 2. To fire, place the nose of the Stapler on the workpiece. The Stapler should not fire if the nose is not depressed. Once depressed, gently and briefly squeeze the Trigger (39) once. Do not fire repeatedly. Staples could bounce off of one another, damaging the work piece or causing PERSONAL INJURY. 3. After disconnecting the Stapler, the Nut (39), near the trigger, can be turned to adjust the depth. After adjusting, be sure to practice on scrap wood before working on a project. Clearing Jams TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION, BEFORE ANY MAINTENANCE OR REPAIRS ARE DONE (including clearing jams): • Wear ANSI-approved safety goggles with side shields. Other people in the work area must also wear ANSI-approved impact safety goggles with side shields. • Release the trigger. • Detach the air supply. • Attempt to fire the Tool into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any fasteners. • Empty the magazine and leave it open during service. 1. Disconnect tool from air hose, empty Magazine A (66) of staples, release any built-up air pressure, and leave the magazine open, as explained above. 2. Safety Cover Bolt (53)FIGURE 1While doing this step and the next, hold the Stapler pointed away from you and any other people or fragile objects - see Figure 1. Remove all three Safety Cover Bolts (53) on the Safety Cover (54). 3. FIGURE 2Safety (52) Safety Cover (54) Lift the Safety Cover (54) off the top of the stapler - see Figure 2. 4. FIGURE 3Driver (19) Driver Cover (57) Carefully slide the Driver Cover (57) off around the Safety (52) and remove the jammed staple - see Figure 3. Use pliers to remove a stuck staple. 5. Inspect the Driver (19) for bends or breakage - see Figure 3. If it is damaged, do not use the tool until it is repaired by a qualified technician. 6. Lightly oil the Driver (19) and replace the Driver Cover (57). Replace the Safety Cover (54), being careful to line up the bolt holes and fit the Safety (52) into the slot. Replace and securely tighten all of the Safety Cover Bolts (53). The Safety (52) must move without sticking. 7. Reload the Stapler. 8. Reconnect the Stapler to the air hose. 9. Press the Safety (52) of the Stapler against an appropriate piece of scrap wood and test fire the Stapler several times, checking for proper operation. 10. Disconnect the Stapler, remove the staples, and store the Stapler in a location out of children’s reach. MAINTENANCE TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION, BEFORE ANY MAINTENANCE OR REPAIRS ARE DONE (including clearing jams): • Wear ANSI-approved safety goggles with side shields. Other people in the work area must also wear ANSI-approved impact safety goggles with side shields. • Release the trigger. • Detach the air supply. • Attempt to fire the Tool into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any fasteners. • Empty the magazine and leave it open during service. Note: If the Stapler leaks air, continually skips staples, does not drive the staple properly, or the Trigger (39) or Safety (52) do not move freely have it serviced by a qualified service technician. 1. After each use, check the tightness on all visible screws. 2. Wipe the Stapler clean daily with a damp cloth and non-flammable cleaning solution. Never soak the Stapler. 3. Make sure that no dirt or debris blocks the fastener discharge area. 4. Any maintenance, service, or repairs, apart from those procedures explained in this manual, are to be attempted only by a qualified technician. REV 10a PARTS LIST Part Description 1 Exhaust Deflector 2 O-Ring 3 Hex. Bolt 4 Head Cap 5 Seal 6 Internal Lining 7 O-Ring 8 Compres...

Dieses Handbuch ist für folgende Modelle:
Nailers - 40072 (631.85 kb)
Nailers - AIR STAPLER 1/4" CROWN, 18 GAUGE 97521 (631.85 kb)
Nailers - AIR STAPLER 1/4" CROWN, 18 GAUGE 40073 (631.85 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien