Anleitung Zusammenfassung


Provide some slack for repositioning of the canister/filter/pump assembly after electrical connections are made. d. One the 35- and 50-pound models, route the 2-conductor and 4-conductor cable through the two PG 13.5 strain reliefs installed in step b. See Figure 23. On the 85-pound model, route both the 2-conductor cable and the 4-conductor cable through the PG 21 strain relief as shown in Figure 24. Note: Ensure strain reliefs are tightened securely around the cable. e. Connect red wire in the 2-conductor cable from the canister/filter/pump assembly to terminal A2 of the pump contactor. See Figure 23. f. Extend 2-conductor cable #223, which is capped in the rear control module. Connect red wire of #223 to the black wire of the 2-conductor cable from the canister/filter/pump assembly. g. Connect the black wire of the #223 cable to terminal A1 of the pump contactor. h. Connect L1, L2, and L3 from the circuit breaker to the input side of the mains contactor, using the 18GA gray wire, included in the kit. i. Connect the 4-conductor cable wires to the pump contactor terminals as follows: wire No. 1 to terminal T1, wire No. 2 to T2, and wire No. 3 to T3. Wire No. 4 (green-yellow) must be connected to the chassis ground. Note: If pump motor rotation is incorrect during the control function test, swap any two wires at terminals T1, T2, or T3 of pump contactor. See Figure 26 for correct motor rotation direction. 7. Verifying electrical connections: a. Secure any loose or dangling wires, using the wire ties. b. Verify that all connections are secure and routed properly. 8. Reassembling machine panels: a. Reassemble rear panel and right front panel. b. Reinstall rear control module cover. 9. Install water recirculation piping: a. Remove the cap on the recirculation inlet on top of the shell. See Figure 20. b. Attach the 1 1/2-inch black hose connector (no clamp grooves), included in the kit, between the shell recirculation inlet and the adapter plate. c. Attach upper recirculation pipe to the hose connector at the recirculation adapter plate on the rear of the washer- extractor. See Figure 26. F232058 Installation Adapter Plate Upper Recirculation Pipe Lower Recirculation Pipe Filter Pump R004I Figure 26 d. Tighten the clamps on the hose connector at the shell recirculation adapter plate. Ensure that the upper recirculation pipe is tight and fully secured. e. Align the lower recirculation pipe to the upper recirculation pipe and the pump outlet. Ensure that the water recirculation platform can be positioned so that the flex hose from the left drain to the canister/filer bends comfortably. If the flex hose appears to be crimped or stretched excessively, flip the lower recirculation pipe around and reposition the water recirculation platform until the flex hose bends comfortably. f. Slide one 1 1/2-inch black connector (with clamp grooves), included in the kit, onto the upper recirculation pipe side of the lower recirculation pipe. g. Assemble the other 1 1/2-inch black connector (with clamp grooves), included in the kit, to the pump outlet. h. Position the lower recirculation pipe between the upper recirculation pipe and the pump outlet. Verify alignment. Secure the lower recirculation pipe to the pump outlet by tightening the clamps on the 1 1/2-inch black connector. i. Slide the other 1 1/2-inch connector between the upper and lower recirculation pipes. Tighten the connector clamps. j. Verify that all pipe connections are tight and fully secure. Verify operation with Control Function test, which follows this section in the manual. F232058 Installation Control Function Test The washer-extractor should be cleaned after the installation is complete. A function test should then be executed on the unloaded machine: 1. Verify that power supply voltage and phase are correct in accordance with the washer-extractor’s requirements. If the Premium Wet Clean Module is installed, 3-phase power must be provided. 2. Open manual shut-off valves to the washer-extractor. 3. Press the Emergency Stop button. 4. Apply power to the washer-extractor. 5. Release the Emergency Stop button. 6. Check the door interlock before starting operation: a. Attempt to start the washer with the door open. The washer-extractor should not start with the door open. b. Close the door without locking it and attempt to start the washer. The washer should not start with the door unlocked. c. Close and lock the door and start a cycle. Attempt to open the door while the cycle is in progress. The door should not open. If the door lock and interlock are not functioning properly, call a service technician. 7. For standard processing, select Cycle 01 by pressing key 0 and key 1 on the keypad. Then press the Start key. Run a complete cycle, checking operation of water inlet valves, drain, and extract functions. F232058 Installation Power Supply AC Drive Connections Motor Leads Main Drive Motor Input Power Block on Washer-Extractor RS T UV W MV001F Figure 27 8. Cyli...

Dieses Handbuch ist für folgende Modelle:
Waschmaschinen - BF35PV (1.17 mb)
Waschmaschinen - BF50PV (1.17 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien