W043 WARNING • Dryer exhaust duct should enter the main duct at an angle of no more than 30° pointing in the direction of the air flow. Ducts entering the main duct from opposite sides should be staggered so as not to oppose each other. See illustration below. DRYER EXHAUST DUCT DRYER EXHAUST DUCT DRYER EXHAUST DUCT DRYER EXHAUST DUCT AIR FLOW MAIN COLLECTOR DUCT 30 ° 30 ° 30 ° D026IE3A 30 ° • Provisions should be made for periodic lint removal and cleaning of the main collector duct. • The outside end of the main duct should have a weather hood (with hinged dampers) installed to prevent passage of weather elements, insects, dust, and dirt into the dryer. • If a weather hood cannot be used, the outside end of the main duct should have a sweep elbow installed, and be directed downward as shown on the following page. If the main duct travels vertically through a roof rather than through a wall, install 180° sweep elbow on the end of the duct with outlet at least 24 inches (61 cm) above the highest part of the building. To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building. W045 WARNING • Sufficient make-up air must be supplied to replace air exhausted from dryer. NOTE: Where the exhaust duct pierces the wall or ceiling, an opening having a diameter of 4 inches (10.2 cm) larger than the diameter of the exhaust duct shall be provided, and the exhaust duct centered within the opening. • Damper, Part No. 58786, should be installed in dryer’s exhaust system. This will prevent a backdraft when dryer is not in use, and will keep the exhaust air in balance within the central exhaust system. IMPORTANT: Provisions must be made for make-up air. IMPORTANT: If several dryers are exhausted into a main collector duct, it is essential that ductwork be adequate in size and properly constructed for efficient operation. 504509 33 WEATHER HOOD OR SWEEP ELBOW (No cap or screen) • Main collector duct should be sized according to specifications shown below. 180° SWEEP ELBOW (No cap or screen) WALL PARAPET ROOF 24" MIN. (60.96 cm)MAIN COLLECTOR DUCT MAIN COLLECTOR DUCT D039IE3A Number of Dryers Minimum Diameter of Horizontal Collector Duct Minimum Diameter of Vertical Collector Duct 2 7 inch (17.8 cm) 8 inch (20.3 cm) 3 8 inch (20.3 cm) 9 inch (22.9 cm) 4 9 inch (22.9 cm) 10 inch (25.4 cm) 5 10 inch (25.4 cm) 11 inch (27.9 cm) 6 11 inch (27.9 cm) 12 inch (30.5 cm) 7 12 inch (30.5 cm) 13 inch (32.6 cm) 8 12 inch (30.5 cm) 14 inch (35.6 cm) 9 13 inch (32.6 cm) 15 inch (38.1 cm) 10 14 inch (35.6 cm) 15 inch (38.1 cm) 11 14 inch (35.6 cm) 16 inch (40.6 cm) NOTE: Main collector duct should be equipped with an auxiliary fan that can maintain the duct airflow at a minimum of 1200 feet (366 m) per minute. If you do not have a fan, clean the main collector duct at least twice a year. 34 504509 Lint Filter . . . CLEAN THE LINT FILTER BEFORE DRYING EACH through the dryer, thus reducing the efficiency of the LOAD. (Refer to illustration below for lint filter dryer. The clothes will take longer to dry and energy will location.) Cleaning the lint filter is important because a be wasted. layer or pad of lint on the filter will block the flow of air LINT FILTER H247IE1A Dryer Motor Overload Protector . . . The motor overload protector stops the motor in the event PUSH-TO-START button. If the overload protector of an overload. After cooling, the overload protector will cycles again, remove the unit from use and call the reset itself. The dryer can be restarted by pressing the service person to correct the problem. 504509 35 36 504509 Operation Instructions for Electromechanical Washers IMPORTANT: Prior to first wash, use an all-purpose cleaner, or a detergent and water solution, and a damp cloth to remove shipping dust from inside of washer drum. Step 1: Load Laundry Load items loosely into wash drum. Step 2: Close Loading Door Close loading door tightly. The washer will not operate with the loading door open. Step 3: Add Laundry Supplies Open dispenser drawer. Measure and add low sudsing detergent (1), bleach (2) and fabric softener (3) to the dispenser drawer (see illustration). Close dispenser drawer. IMPORTANT: If using detergents made for topload washers, avoid oversudsing by using 1/2 of the recommended amount. . . . H248I H249I Dispenser drawer requires a special tool for removal. Contact a service person if removal is necessary. W236 CAUTION 3 2 1 H250I Step 4: Step 6: Determine Proper Controls for Select Fabric Selector Washer Set regular loads at NORMAL or PERM PRESS. Set delicate loads at DELICATE. The direction of the arrow indicates which controls are for the washer. H160IE1A Step 5: Set WASH/RINSE Temperatures Set at HOT (COLD rinse), WARM (COLD rinse) or COLD (COLD rinse). NOTE: Always follow Manufacturer’s care labels. 686515c Step ...