|
Anleitung Zusammenfassung
Reactivation Switch Turns the unit on after a timeout. Press the button from the bottom. Green and Red LEDs When the red LED is on, the laser is on. If the green LED flashes on, the scanner has read a bar code successfully. Communication to the host is complete when the receiver beeps. Infrared Object Sensor When a specified time has elapsed without any scanning, the unit will enter a “standby” mode. To reactivate the unit, remove the current object and present an object in front of the output window again. Output Window This aperture emits laser light. COMPONENTS OF THE MS6130 SERIES STAND The following are the components used to build the MS6130 series stand (MLPN: 45880). 1. Cradle 2. Stand Charger Pack 3. Pole Cover 4. Flex pole 5. Stand Base Cover 6. Stand Base 7. Charger Transformer 8. Charger Pack Screws 9. Mounting Screws 10. Lock Washer 6 1 3 4 5 10 9 7 8 2 CABLE CONNECTS THROUGH OPENING Figure 5: Scanner Parts INSTALLATION OF THE MS6130 SERIES STAND Refer to for numbered components on the previous page 1. Use the stand base (6) as a template to drill and mount the base to the counter using the mounting screws (9) provided. 2. Feed the wire from the transformer (7) through the slot in the base cover (5) approximately 9" of the wire. 3. Press the base cover (5) over the base (6). 4. Attach the flex pole ( 4) to the base (6). 5. Slide the flex cover (3) over the pole ( 4) and wire. 6. Attach the cradle ( 1) to the flex pole (4) using the lock washer ( 10) to connect the transformer. 7. Insert the transformer plug into the connector inside the stand charger pack (2). 8. Clip the charger pack to the bottom of the cradle (1) lock in place using two screws ( 8) . Stand LED Indicators (with the scanner in the stand) No LED indicates trickle charge and the green LED indicates fast charge. To change from trickle charge to fast charge, simply lift the scanner from the stand and replace. Note: When both scanner LEDs blink, it is an indication of a low battery. INSTALLATION OF THE 6000 SERIES UNIVERSAL CHARGING STAND MLPN: 45558 - 115V, 45559 - 230V and 45560 - 240V (UK) Green LED (Charge Status) Red LED (Power) Transformer Figure 6: Universal Charging Stand PERMANENT COUNTER TOP INSTALLATION 1. Separate weighted base from rotating base by removing the (4) four screws. 2. Use the rotating base as a drill template. 3. Use the (4) four wood screws provided to mount the base to the counter top securely. 4. Snap the cup assembly to the base. Note: For non-permanent installation, snap the cup assembly onto the weighted base CHARGE STATE CHARGE LED STATUS Battery Absent LED off Charge Pending LED on for 0.125sec, off for 1.375sec Fast-Charge LED on Charge Complete and Top-Off LED on for 0.125 sec, off for 0.125sec NICD BATTERY CHARGER WITH RECONDITIONING FEATURE MLPN: 45561 - 115V and 45562 - 230V RECOMMENDED USE Figure 7: Reconditioning Discharge Cycle Switch Green LED (Charge Status) Red LED ( Power) Transformer How to Recondition 1. Place the scanner into the charge stand. 2. Push the stand tilt cup in the extreme down position to expose the hole for the discharge cycle switch. 3. Use a pin to push the discharge cycle switch located beneath the hole. 4. When the discharge mode is initiated the green LED flashes. To maintain charge capacity, the NiCd batteries must be discharged fully before charging. We call this process reconditioning. Recondition if: • The batteries were not used within 20 days • The batteries were not discharged (approximately two hours of continuous operation) at least once a week • Low battery indicators: • Both LED’s on the scanner blink • The scanner quietly beeps twice while scanning Recondition once a week if: • The batteries do not get discharged for more than 20% (approximately . hour) of their capacity before recharging. Recondition once every two weeks if: • The batteries do not get discharged for more than 50% (approximately 1 hour) of their capacity before recharging. Note: The day to day usage of the NiCd batteries will determine the frequency of the discharges (reconditioning). Charge State CHG LED Status Battery Absent LED off Charge Pending LED on for 0.125sec, off for 1.375sec Discharge-Before- Charge LED on for 1.375sec, off for 0.125sec Fast-Charge LED on Charge Complete Top- Off LED on for 0.125 sec, off for 0.125sec VISUAL INDICATORS The scanner has red and green LEDs. When the scanner is on, the LEDs indicate the status of the scan and scanner. No Red or Green The scanner will turn off if the scanner has been dormant for a specified time. To reactivate the unit, direct the output window up then down toward the bar coded product. If the unit has been dormant for longer than 10 minutes, reactivating the unit by pressing the button on the side of the MS6130 will be necessary. Red Flash; Green Flash; When the scanner first receives power, the steady red LED will flash, followed by the green LED. When the laser is on, the red LED will also be on. This occurs when an object is ...
Dieses Handbuch ist für folgende Modelle:Scanner und Kopierer - MS6130 (781.75 kb)