Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Xerox, modell 2300

Hersteller: Xerox
Dateigröße: 6.34 kb
Dateiname: 2300.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


DATE: Emergency No. (585) 422-2177 0607 6/18/83 2/26/90 EH&S Inquiries (8GG) 828-6571 Manufacturer's Address Rochester, New York 14644 Product Designation 2300 Product Code 930 Section II - Electrical Information Line Voltage Line Current Freq. (Volts) (Amps) (Hertz) 115 9 60 Branch Cir. Protection (Amps) 15A Sole or Multi-use (sole use recommended) Line Cord / Plug Specification Single Phase 2 Wire + Ground NEMA 5-15R / 5-20R Power Consumption (Watts)* Running: 1,000 Standby: 160 Agency Approvals UL File Number E24G14 CSA LR Number LR2196 Section III - Supplies Dry Imager (magnetic) Dry Imager Developer Fuser Oil Photoreceptor Xerox Part No. 6R13G 6R189 5R129 8R79 1R19 Material Safety Data Sheet A-0009A A-0009 B-0209A D-0407 Article (C2) ** Section IV - Environmental Information Product Size Heat Emission* (Centimeters/Inches) (BTU/HR) D: 56 / 22.1 Running: 3,800 W: 95 / 37.4 Standby: 607 H: 33 / 13.0 Environmental Limitations Min Max Relative Humidity (%) 10 85 Ambient Temp. (oC) 10 32 Floor Space Requirements (Meters/Feet) 2 x 2 / 6.6 x 6.6 Weight (K GramsILbs.) 79 I 174 * Based on a five-minute average ** MSDS is not required by OSHA, Hazard Communication Std., 29CFR or WHMIS HPA (Section II (2) http:II PRODUCT: 2300 PSDS No. 0607 Section V - Emission/Exposure Information* Light Source Long term viewing of exposure lamp may be uncomfortable but not harmful. Electromagnetic Emissions US FCC: Class A Canada DOC: Class A Germany VDE: Class B Audible Noise Running: 59.5 dB (A) Standby: 46.5 dB (A) Impulse: 74.0 dB (a) TLV 85.0 dB (A) Ozone 92 ug/min 0.009 ppm (TWA) 0.024 ppm (Peak) TLV 0.1 ppm Concentration Based on Customer Simulation Model: Daily Copy Volume 270 copies / 7.84 hours Room Size 5.0 m3 1/2 Air Room Change per Hour Dust TLV 3 0.024 - 0.31 mg/m3 10 mg/m3 Selenium TLV 3 < 0.035 - 0.05 ug/m3 200 ug/m3 Arsenic PEL 3 < 0.022 ug/m3 10 ug/m3 Nitrogen Dioxide TLV < 0.04 ppm 3 ppm * TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for a normal eight hour workday. 07/07/97 All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions. http://www.xerox.com:80/environment.html...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien