Login:
Stimmen - 4, Durchschnittliche Bewertung: 5 ( )

Anleitung Datalogic Scanning, modell 9504

Hersteller: Datalogic Scanning
Dateigröße: 1.87 mb
Dateiname: Magellan-9500_PRG.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


See Chapter 4, Scale Error Reporting, if vibration is suspected of causing operational problems. Installation Overview The preceding Site Preparation Overview dealt with installed location and counter preparations to accommodate the scanner or scanner/scale. Having completed those steps, physical installation of the scanner or scanner/ scale can begin. The following instructions apply to all models. This chapter describes: 1. Unpacking the unit. 2. Verifying operation before connecting to a POS system. 3. Routing and connecting cables. 4. Validating that your scanner communication parameters match the POS terminal’s system requirements. 5. Confirming connection to the EAS system. 6. Functional testing to verify operation when connected to the POS system. 2-18 Magellan® 9500 Installation Overview Unpacking NOTE The following text describes each of these steps. To unpack the unit: • Inspect the package for signs of damage that may have occurred during shipping. If damage is found, report it to your carrier immediately. • Lift out the accessory box containing the AC/DC Power Supply, optional Remote Scale Display and cable (if present), and the Quick Reference Guide. • Remove the Quick Reference Guide and familiarize yourself with the unit’s controls and features. Leave the guide at the checkstand when the installation is complete. • Remove the protective packing and carefully lift the unit from the carton. Be sure to save the box and all packing material. In the event of failure, the unit must be returned to the factory in its original packaging. • Carefully lift off the All Weighs™ Platter as shown in Figure 2-22 and remove the protective foam pieces securing the weigh mechanism. Set the platter back in place. For added protection during shipment, the All Weighs™ Platter is covered with a tight-fitting layer of vinyl as shown in Figure 2-10. This vinyl layer MUST BE REMOVED before placing the unit into service. Product Reference Guide 2-19 Figure 2-10. Remove Protective Vinyl Protective vinyl MUST be removed from the platter before use. • Proceed to the Operational Verification instructions below. Operational Verification Follow these steps to ensure that your unit has arrived undamaged and is fully functional before installing it in the counter and connecting it to your POS system. 1. Connect the scanner and the EAS antenna to the EAS Controller Box (see Figure 2-20 and Figure 2-21) and power-on the controller box. 2. If the unit is a scanner/scale, connect the Remote Scale Display to the proper connector on the unit’s connector panel (refer to Figure 2-14). Note that if the Remote Scale Display is not connected, a scanner power-up Selftest will sound a long, low beep, and the number “8” will appear on the 7-segment display indicating a remote display error. Power-down, connect a known-good Remote Display to the appropriate port, and restart to correct this problem. Alternatively, you can disable the Remote Display using programming bar codes (see Chapter 6, Programming for more information). 3. Connect the power cable at the scanner, then at the AC outlet. 2-20 Magellan® 9500 Installation Overview When power is applied to the unit, the normal indicator sequence is: • The scanner indicator (top-most, green LED) will be lit (dim) steadily. • The EAS indicator (bottom-most, tri-color LED) will flash ON/ OFF during power-up. Additionally, the 7-segment display will flash the number ‘9’. indicating the EAS system is being initialized. • If the Selftest detects a problem, the 7-segment display will display a number code. Refer to Chapter 4, Problem Isolation, for a description of failure codes and problem isolation procedures. Scale calibration may be necessary to obtain a zero reading on the display on rare occasions. NOTE 4. The unit should be permitted to reach thermal equilibrium before proceeding to the next steps. (Reference the topic Warm-Up Time in Chapter 1.) When the unit is moved from a cooler temperature (such as a storage area) to a warmer environment (such as a check- stand location), a period of 60 minutes must be allowed to acclimate the unit to ambient conditions. Once installed and powered up, a “power-up” warm-up period of 15 minutes must be allowed before calibrating or performing weighing operations. These two warm- up periods may run concurrently. 5. Verify that the scanner or scanner/scale passes an operational test by observing the following: Product Reference Guide 2-21 NOTE Scanner: Pass UPC/EAN bar code labels in front of the scanner’s windows. Since the interface cable is not yet connected to the POS terminal, the scanner may be limited to reading only one or two labels (see the note that follows). The scanner indicates when each label has been successfully read by flashing the green scanner light and emitting a good read tone (beep). When not connected to the host, the scanner may be limited to reading only one or two labels. (This limitation is dependent upon the interface type.) To ...

Dieses Handbuch ist für folgende Modelle:
Scanner und Kopierer - 9500 (1.87 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien