Anleitung Datalogic Scanning, modell MAGELLAN 1400I
Hersteller: Datalogic Scanning Dateigröße: 826.08 kb Dateiname: 1400i_um.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
START / END PROGRAMMING BAR CODES 6 Minutes 7 Minutes 8 Minutes 9 Minutes 10 Minutes DEFAULT 12 Minutes 15 Minutes 30 Minutes 1 Hour Magellan® 1400i LED and Beeper Indicators LED and Beeper Indicators Power On Alert Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation. START / END PROGRAMMING BAR CODES Disable Enable DEFAULT Product Reference Guide General Features Good Read: When to Indicate This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are: • Good Read = Indicate after decode • Good Read = Indicate after transmit • Good Read = Indicate after CTS goes inactive, then active This option (Indicate after CTS goes inactive, then active), which uses CTS, is only valid for RS-232 interfaces. NOTE START / END PROGRAMMING BAR CODES After Decode DEFAULT After Transmit After CTS goes inactive, then active Magellan® 1400i LED and Beeper Indicators Good Read Beep Control This feature enables/disables the scanner’s ability to beep upon a successful decode of a bar code. START / END PROGRAMMING BAR CODES Disable Enable DEFAULT Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.) START / END PROGRAMMING BAR CODES Low Medium DEFAULT High .001402 Product Reference Guide General Features Good Read Beep Length Specifies the duration of a good read beep. START / END PROGRAMMING BAR CODES 60msec DEFAULT 80msec 100msec 120msec 140msec 160msec 180msec 200msec 2-10 Magellan® 1400i Productivi ty Index Reporting (PIR) Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. START / END PROGRAMMING BAR CODES Low Medium High DEFAULT Productivity Index Reporting (PIR) When PIR is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer, indicating how easy the label was to read. This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability. NOTE START / END PROGRAMMING BARCODES Disable DEFAULT Enable Product Reference Guide General Features Scanning Features Aiming Pointer This feature enables/disables the Aiming Pointer for all symbologies. START / END PROGRAMMING BAR CODES Disable DEFAULT Enable always on Targeted Scanning Mode Upon pressing the button, the scanner will project an aiming pattern to assist in centering over the bar code. Scanning then takes place as soon as the button is released. When add-ons are enabled and a bar code is being read while in Targeted Mode, position the pointer at or near the end of the base label to ensure the scanner will read both the base and add-on label. NOTE Targeted Scanning Mode will read bar codes in any orientation. The scanner will return to full pattern Omni-directional Mode after either of the following has ocurred: -Good Read + Target Mode: Linger Time has elapsed. -Target Mode: Active Time + Target Mode: Linger Time has elapsed. Configuration options for Targeted Scanning Mode are: • Target Mode: Active Time • Target Mode: Linger Time 2-12 Magellan® 1400i Scanning Features Target Mode: Active Time Specifies the time duration the scanner attempts to decode labels while in the targeted mode of operation. START / END PROGRAMMING BAR CODES Extra Short Duration Short Duration Medium Duration DEFAULT Long Duration Product Reference Guide General Features Target Mode: Linger Time Specifies the time duration the scanner remains in the targeted mode of operation after reading a bar code or after Target Mode: Active Time has expired, before reverting to Omni-directional Mode. The linger timer starts upon a good read or upon timeout of Target Mode: Active Time; whichever is earliest. A button press at any time will reset the process back to the start. Active Time and Linger Time settings are totally independent from one another. During the period Linger Time is active, no bar codes can NOTE be read, no matter what mode the scanner is in. START / END PROGRAMMING BAR CODES Short Duration Medium Duration DEFAULT Long Duration 2-14 Magellan® 1400i Scanning Features Wake Up Intensity This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode. Lower settings provide greater sensitivity. START / END PROGRAMMING BAR CODES 5% 8% 10% DEFAULT 15% 20% .03B819 25% 30% 35% Product Reference Guide General Features Wake Up Intensity — cont. START / END PROGRAMMING BAR CODES 40% 50% 60% 70% 80% 2-16 Magellan® 1400i Chapter 3 Interface Related Features At the time of this writing, the Scanner supports the interfaces listed in Table 3-1. Select the desired interface type from the table...