Anleitung Poulan, modell 530087725
Hersteller: Poulan Dateigröße: 194.51 kb Dateiname: NOUS2000_530087725.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
D Mix and pour fuel in an outdoor area; store fuel in a cool, dry, well ventilated place; and use an approved, marked container for all fuel purposes. D Do not smoke while handling fuel or while operating the unit. D Make sure the unit is properly assembled and in good operating condition. D Do not fill fuel tank while engine is running. D Avoid spilling fuel or oil. Wipe up fuel spills before starting engine. D Move at least 10 feet (3 meters) away from fuel and fueling site before starting engine. --2 longer turning to avoid serious injury from the rotating blades. D Inspect unit before each use for worn, loose, missing, or damaged parts. Do not use until unit is in proper working order. D Keep outside surfaces free of oil and fuel. D Never start or run engine inside a closed room or building. Breathing exhaust fumes can kill. D To avoid static electricity shock, do not wear rubber gloves or any other insulated gloves while operating the unit. D Do not set unit on any surface except a clean, hard area while engine is running. Debris such as gravel, sand, dust, grass, etc. could be picked up by the air intake and thrown out through discharge opening, damaging unit, property, or causing serious injury to bystanders or operator. D Avoid dangerous environments. Do not use in unventilated areas or where explosive vapors or carbon monoxide build up could be present. D Do not overreach or use from unstable surfaces such as ladders, trees, steep slopes, rooftops, etc. Keep firm footing and balance at all times. D Never place objects inside the blower tubes; always direct the blowing debris away from people, animals, glass, and solid objects such as trees, automobiles, walls, etc. The force of air can cause rocks, dirt, or sticks to be thrown or to ricochet which can hurt people or animals, break glass, or cause other damage. D Never run unit without the proper equipment attached. When using your unit as a blower, always install blower tubes. When using your unit as a vacuum, always install vacuum tubes and vacuum bag assembly. Make sure vacuum bag assembly is completely zipped. D Check air intake opening, blower tubes, vacuum tubes, and elbow tube frequently, always with the engine stopped and the spark plug disconnected. Keep vents and discharge tubes free of debris which can accumulate and restrict proper air flow. D Never place any object in the air intake opening as this could restrict proper air flow and cause damage to the unit. D Never use for spreading chemicals, fertilizers, or other substances which may contain toxic materials. D To avoid spreading fire, do not use near leaf or brush fires, fireplaces, barbecue pits, ashtrays, etc. D Use only for jobs explained in this manual. - -- MAINTAIN YOUR UNIT PROPERLY D Have all maintenance other than the recommended procedures described in the Operator’s Manual performed by your Service Dealer. D Disconnect spark plug before performing maintenance except for carburetor adjustments. D Use only recommended POULAN PRO replacement parts; use of any other parts may void your warranty and cause damage to your unit. D Empty the fuel tank before storing the unit. Use up fuel left in carburetor by starting the engine and letting it run until it stops. D Do not use any accessory or attachment other than those recommended by the manufacturer for use with your unit. D Do not store the unit or fuel in a closed area where fuel vapors can reach sparks or an open flame from water heaters, electric motors or switches, furnaces, etc. D Store in a dry area out of reach of children. SPECIAL NOTICE: For users on U.S. Forest Land and in some states, including California(Public Resources Codes 4442 and 4443), Idaho, Maine, Minnesota, New Jersey, Oregon, and Washington: Certain internal combustion engines operated on forest, brush, and/or grass covered land in the above areas are required to be equipped with a spark arrestor, maintained in effective working order, or the engine must be constructed, equipped, and maintained for the prevention of fire. Check with your state or local authorities for regulations pertaining to these requirements. Failure to follow these requirements is a violation of the law. This unit is not factory equipped with a spark arrestor; however, a spark arrestor is available as an optional part. If a spark arrestor is required in your area, contact your Authorized Service Dealer for the correct kit. The spark arrestor, blower tubes, and nozzles must be assembled to the unit to be in full compliance with the regulations. SPECIAL NOTICE: Exposure to vibrations through prolonged use of gasoline powered hand tools could cause blood vessel or nerve damage in the fingers, hands, and joints of people prone to circulation disorders or abnormal swelling. Prolonged use in cold weather has been linked to blood vessel damage in otherwise healthy people. If symptoms occur such as numbness, pain, loss of strength, change in skin color or texture, or loss of feeling in the fi...