Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Best, modell WC26E

Hersteller: Best
Dateigröße: 1.08 mb
Dateiname: e25a8d36-55e7-400c-82ad-e69c20fc43ec.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


b) the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown. 2. After wall surface is finished, secure the mounting bracket to framing with (2) 4.8 x 38mm mounting screws. See chart below for mounting bracket location. HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note a) 28” MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP 47-1/4” CEILING HEIGHT 8-FOOT 9-FOOT 22” 23” 24” 25” 26” 27” 41-1/4” 42-1/4” 43-1/4” 44-1/4” 10- FOOT (see note b) 45-1/4” 46-1/4”41-1/4” 42-1/4” 43-1/4” 44-1/4” 41-1/4” 42-1/4” 43-1/4” 44-1/4” 47-1/4”45-1/4” 46-1/4” FRAMING BEHIND WOOD CROSS SUPPORT WOOD CROSS SUPPORT BEHIND DRYWALL DRYWALL FIG. 9 INSTALL MOUNTING BRACKET 1. Construct wood wall framing that is flush with interior surface of wall studs. Fig. 9. Make sure: a) the framing is centered over installation location. b) the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown. 2. After wall surface is finished, secure the mounting bracket to framing with (2) 4.8 x 38mm mounting screws. See chart below for mounting bracket location. HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note a) 28” MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP 47-1/4” CEILING HEIGHT 8-FOOT 9-FOOT 22” 23” 24” 25” 26” 27” 41-1/4” 42-1/4” 43-1/4” 44-1/4” 10- FOOT (see note b) 45-1/4” 46-1/4”41-1/4” 42-1/4” 43-1/4” 44-1/4” 41-1/4” 42-1/4” 43-1/4” 44-1/4” 47-1/4”45-1/4” 46-1/4” FRAMING BEHIND WOOD CROSS SUPPORT WOOD CROSS SUPPORT BEHIND DRYWALL DRYWALL FIG. 9 Notes: a. Minimum hood distance above cook top must not be less than 22”. A maximun of 28” above cook top is highly recommended for best capture of cooking impurities. Distances over 28” are at the installer and user’s discretion; and if ceiling height and flue length permits. b. Requires optional 10’ flue extension, ducted model AEWC26xB. - 10 INSTALL FLUE MOUNTING BRACKET 1. Assemble the flue mounting bracket, adjusting outside width as shown. Fig.10 2. Carefully center the mounting bracket directly over the range hood location. 3. Secure the bracket assembly to the ceiling using (2) 4.8x38mm mounting screws and drywall anchors (Fig. 11). Make sure the bracket is pushed into the corner, tight against the wall and centered over the hood. FLUE MOUNTING BRACKET 9-13/16” (24.9 cm) FIG.10 3.9 x 6 mm FLAT HEAD BRACKET SCREWS FIG.11 4.8x38mm MOUNTING SCREWS DRYWALL ANCHORS - 11 INSTALL THE HOOD Note: On stainless steel hoods, carefully remove the plastic protective film from all exterior surfaces of the hood and decorative flues, prior to final installation. Note: at least two people will be required to mount the hood. 1. Raise the hood into its mounting position. 2. Align the rectangular opening on the back of the hood with the wall-mounting bracket. Gently lower the hood until it securely engages the bracket. Fig. 12. 3. Level the hood with (2) 3.9x9.5mm mounting screws and secure with (4) 4.8x38mm mounting screws. Use drywall anchors provided if wall studs or framing are not available. Fig. 12. 4. Install the discharge collar inside the tabs and secure with (2) 3.9 x 9.5mm screws. Fig. 13. 5. Attach 8” round metal duct between the hood’s discharge collar and duct that leads to the blower. 6. Tape all duct joints to make them secure and air tight. 7. Plug the power cord into the electric wall receptacle. Tuck excess cord behind the flue. FIG. 12 MOUNTING SCREWS (4.8x38mm) RECTANGULAR CUTOUT WALL FRAMING MOUNTING BRACKET MOUNTING SCREWS (3.9x9.5mm) DISCHARGE COLLAR FIG.13 TABS - 12 INSTALL THE HOOD, cont’d 7. Carefully place the decorative flue on the hood. Fig. 14. ROOMS WITH 10-FOOT CEILINGS Rooms with 10-foot ceilings require flue extension model AEWC26xB, available from your local dealer. 8. Discard the upper flue supplied with the product. Replace it with the flue extension. 9. Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 15. 10. Secure the flue with (2) 3.9x9.5mm mounting screws. Fig. 15. 11. Secure the lower flue to the upper flue with (1) 2.9x9.5mm mounting screw. Drill the hole (1/16” Diameter) in the upper flue. Fig. 16. 2.9x9.5mm MOUNTING SCREW FIG.16 LOWER FLUE UPPER FLUE 3.9x9.5mm MOUNTING SCREWS FIG.15 FIG.14 - 13 INSTALL FILTERS 1. To remove the GREASE filter, grip the latch tab and pull it down. This will disengage the filter from the hood. Tilt the filter downward and remove. Fig. 17. 2. To install the GREASE filter, align rear filter tabs with slots in the hood. Pull latch tab down, push filter into position and release. Make sure the filter is securely engaged after installation. Fig.17. NOTE: Prior to use, remove protective film from the filter frame. GREASE FILTER FIG. 17 WARRANTY BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THE...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien