Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Echo, modell PB-755S T

Hersteller: Echo
Dateigröße: 639.81 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The straps are adjustable. 14. THROTTLE TRIGGER -Spring loaded to return to idle when released. During acceleration, press trigger gradually for best operating technique. 15. LOCKING KNOB -Allows operator to adjust handle position for optimum comfort and control. 16. BLOWER PIPES -Exclusive positive locking system. 17. FLEXIBLE PIPE -Allows for full range of movement. POWER BLOWER OPERATOR'S MANUAL CONTENTS PB-755S H __ 1 -Power Head __ 1 -Flex Pipe __ 1 -Pipe w/swivel __ 1 -Straight Pipe __ 1 -Straight Pipe __ 1 -Operator's Manual __ 1 -Warranty Registration Card __ 1 -ECHO Emissions and Warranty Statement __ 1 -Plastic Bag __ 2 - Clamps w/screws __ 1 -Stick Handle __ 1 -Bolt 6x45 __1 -Washer 6 __1 -Wing Nut __ 1 -Echo Power Blend X TM 2-stroke oil sample PB-755S T __ 1 -Power Head __ 1 -Flex Pipe __ 1 -Pipe w/swivel __ 1 -Straight Pipe __ 1 -Straight Pipe __ 1 -Operator's Manual __ 1 -Warranty Registration Card __ 1 -ECHO Emissions and Warranty Statement __ 1 -Plastic Bag __ 2 - Clamps w/screws __ 1 - Guide Loop __ 1 -Echo Power Blend X TM 2-stroke oil sample 12 ASSEMBLY PB-755SH WARNING Never perform maintenance or assembly procedures with engine running or serious personal injury may result. INSTALL BLOWER PIPES / STICK HANDLE (H) 1. Assemble clamps (A) onto both ends of flexible pipe (B). 2. Assemble swivel pipe (C) into flexible pipe (B) and tighten clamp (A). 3. Assemble flexible pipe (B) to elbow (D) on blower and tighten clamp (A). NOTE A light lubricant may be used to ease assembly of flexible pipe to blower elbow. A AB D C B 4. Loosen wing nut (E) completely and open stick handle clamp. 5. Align notches (F) in handle clamp with tabs (G). 6. Slide stick handle onto swivel pipe (C). Stick handle should be angled away from operator. 7. Position stick handle (H) for comfortable operation, and tighten wing nut (E). 8. Assemble straight pipe (I) onto swivel pipe (C), until you feel light resistance. Do not force connection. Hold swivel pipe and turn straight pipe clockwise, engaging positive locking channels, until connection is firm. Do not force connection. 9. Assemble straight pipe with decal (J) to straight pipe (I) as in step 8. NOTE Blower use will eventually loosen pipe connections. Exclusive positive locking system allows pipes to be tightened. If loosening occurs, remove two straight pipes and install according to instructions 8 & 9. H G G F E C I J POWER BLOWER OPERATOR'S MANUAL PB-755ST WARNING Never perform maintenance or assembly procedures with engine running or serious personal injury may result. INSTALL BLOWER PIPES (T) 1. Place guide loop (G) across large clamp, and turn until clip fully engages clamp band. NOTE Clamp with cable guide loop (G) fits large end of flexible pipe (B). 2. Assemble clamps (A) onto both ends of flexible pipe (B). 3. Assemble flexible pipe (B) to elbow (D) on blower. Position guide loop (G) on inside (blower side) of flexible tube and tighten clamp (A). NOTE A light lubricant may be used to ease assembly of flexible pipe to blower elbow. NOTE Hang handle freely from blower to assure throttle cable is not twisted before installing handle (E). 4. Position cable between the elbow (D) and frame and along the top of the flexible pipe. Loosen knob (H) on handle (E). Align notch in handle with tabs (F). Install onto swivel pipe (C) past long ridges in pipe. 5. Assemble swivel pipe (C) into flexible pipe (B) and tighten clamp (A). 6. Clip throttle cable into throttle cable guide loop (G). 7. Move handle (E) to desired position. Tighten knob (H) hand tight. 8. Assemble straight pipe (I) onto swivel pipe (C), until you feel light resistance. Do not force connection. Hold swivel pipe and turn straight pipe clockwise, engaging positive locking channels, until connection is firm. Do not force connection. 9. Assemble straight pipe with decal (J) to straight pipe (I) as in step 8. G G E B F D G A AB CH G E H E I J C NOTE Blower use will eventually loosen pipe connections. Exclusive positive locking system allows pipes to be tightened. If loosening occurs, remove two straight pipes and install according to instructions 8 & 9. 14 OPERATION WARNING Moving parts can amputate fingers or cause severe injuries. Keep hands, clothing and loose objects away from all openings. Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete stop before removing obstructions, clearing debris, or servicing unit. Blower housing may contain shredder blades and other sharp edges that can cause serious injuries if touched, even if engine is off and blades are not moving. Wear gloves to protect hands from sharp edges and hot surfaces. WARNING Operation of this equipment may create sparks that can start fires around dry vegetation. This unit is equipped with a spark arrestor and a spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements. NOTICE: Use of unmixed, improperly mix...

Dieses Handbuch ist für folgende Modelle:
Lüftungs - PB-755S H (639.81 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien