Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Kawai, modell Digital Electronic Organs SR50

Hersteller: Kawai
Dateigröße: 3.22 mb
Dateiname: 4d4d6c0b-718f-aae4-05fd-70fc579ecaf9.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If you press the wrong switch, you may, if you are still holding the WRITE key down, recover from the error by pressing the correct switch. • Cancelling the WRITE command, returning to step 3, and selecting another rhythm pattern or variation erases the results of the current editing session. You may, however, change the FILL IN, INTRO, or ENDING specification without losing your work. • WARNING The above WRITE procedure automatically overwrites the current memory contents with the new pattern. If you plan to make extensive use of this programming capability, we recommend that you maintain careful records of what you have saved and where. 31 (10) Release the WRITE key to start the WRITE operation. The process takes only a few seconds. Note: The message OK appears on the display when the operation is complete. / I PROGRAM J= / / / / LJ I ' (11) If the message OK does not appear, go back to step 9. Note: The organ will not allow you to store a FILL-IN, INTRO, or ENDING pattern as PROGRAM I or PROGRAM II. Neither will it let you store patterns for these two areas in the areas designated for these rhythm variants. ■ Exchanging the Data of PROGRAM I and II (12) Press the rhythm selector and VARIATION, FILL-IN and/or INTRO/ENDING switches which LEDs are lighting so that they all will go out. (13) Simultaneously press the MOVE and WRITE keys on the lower keyboard. (14) Simultaneously press all three FILL IN SELECT switches so that their LEDs stop flashing and go out. Note: This command is available at all times during the editing sesson. -FILL IN SELECT- II. Advanced Procedures ■ Editing INTROs and ENDINGs Repeat steps 1 -3 of the basic pattern (p.29). (1) Specify INTRO or ENDING: Press the INTRO/ ENDING switch once for INTRO, twice for ENDING, or a total of three times to cancel. Note: The lower left hand corner of the display indicates the three possible states with an I, E, and blank, respectively. PROGRAM j= I / n I I /' n.LJ PROGRAM I / n r I I' I I. LJ PROGRAM j= I / n r I V I U.J (2) Press the RHYTHM switch and edit with the basic procedure. (3) To store the results, hold down the key labelled WRITE (the first C on the lower keyboard), press the switches for the appropriate storage area, and then release the WRITE key. Note: The WRITE operation automatically clears the INTRO/ ENDING switch setting. 32 I Listening to a Particular Instrument (1) To limit the rhythm pattern to a particular instrument, hold down the key labelled EXTRACT (the first C# on the lower keyboard) and press the key corresponding to that instrument. (3) To add other instruments, keep the EXTRACT key switch pressed and press the appropriate keys corresponding to the instruments you would like to add. Release the EXTRACT key to return to the complete pattern. I Correcting Timing Errors It is often difficult to ensure precise timing when the pattern contains a number of instruments. The SR Series therefore provides facilities for automatically adjusting note positions so that they line up at regular intervals within the bar. (1) Specify the timing interval by holding down the appropriate key combination — (the first F# on the lower keyboard) or (the first G#) plus the optional triplet (the first A#) — as you add notes to the pattern. The organ will then automatically shift notes that are not at the exact positions. (See chart on the next page for examples.) Note: This function does not affect the position of any existing notes for the same instrument. • Compound Example This pattern requires the use of three different timing intervals: for the part labelled A, J\ for B, and Ji and triplets for C. (1) Stop the rhythm. (2) Specify the timing interval by holding down the appropriate key combination — (F#) or (G#) plus the optional triplets (A#). (3) Without releasing this combination, press the key for an instrument to automatically align the entire pattern for that instrument. I Delays A built-in function allows you to introduce a slight delay between an instrument and the others. (1) Use the EXTRACT key to select the desired instruments. (2) Hold down the EXTRACT key and press the MOVE key to introduce slight delays for particular segments. The delay time depends on the tempo. (3) To shift the instrument back to the original position for a particular segment, hold down the EXTRACT key and press both the MOVE and RESET keys. 33 34 ■ Starting from Scratch — ALL CLEAR (1) For the first two steps of the general procedure, choose a prerecorded pattern with the same time signature and length in bars. Note: These parameters automatically appear on the multifunction display whenever you select a rhythm pattern. (2) Simultaneously press the two keys labelled ALL CLEAR (the first G and A on the lower keyboard). (4) Record and edit the new pattern with the same techniques as the basic procedure. ■ Changing Hand Percussion Assignments The R...

Dieses Handbuch ist für folgende Modelle:
Tasteninstrumente - Digital Electronic Organs SR70 (3.22 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien