Login:
Stimmen - 2, Durchschnittliche Bewertung: 5 ( )

Anleitung NotaTech, modell D/3

Hersteller: NotaTech
Dateigröße: 379.27 kb
Dateiname: 8a7db322-4275-4d24-c10c-00558a2fc4fc.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


It communicates at 12 mbps via an available USB 1.0/2.0 port on an OCM, DCM or CDCM. The D/3 Keyboard contains an audible alarm horn with an adjustable volume control and an alarm relay consisting of a single set of Form C contacts. D/3 control and display functions can be protected by limiting access to them. To access a protected function, the user must have either a master key to operate the key lock in the D/3 Keyboard or a password and a Console-Enabling Index, CEI. The master key bypasses both the passwords and CEIs to access all protected functions. The D/3 USB Keyboard functions in parallel with a standard QWERTY keyboard. When connected and configured either keyboard may be used. Drivers and virtual communication port software for Windows 2000, XP, Vista, and Server 2003 are included on the D/3 Keyboard installation CD. The D/3 Keyboard case is made of steel. The keypad is a one piece rubber overlay that is sealed to the case making the top impervious to dirt or liquid spills and easy to clean. The standard case has openings in the rear near the connectors; however, a wash down version of the keyboard is available by special order. Power for the keyboard functions is provided from the USB connection. The universal 12 VDC power supply (included) is only required when the audible horn or Form C contacts are utilized. Dedicated Keys The D/3 USB Keyboard simplifies operator tasks by providing dedicated keys, grouped into a logical arrangement for operators, for selection and process control. There are 16 quick-select keys which are used to select faceplates and parameters from various OCM displays. Six keys dedicated to alarms are used to acknowledge alarms, silence audible alarms, and review alarms. Ten display function keys perform general operations for viewing and editing of displays. Eight sequence logic keys are used for interacting with units, recipes, and messages. Five continuous control keys allow direct access for changing setpoints, outputs, and other functions. Finally, four keys provide functions for modifying parameters and four keys are used to ramp values. See Operator Console User’s Guide for additional information about the D/3 Keyboard functions. D/3 USB Keyboard D/3 USB Keyboard ® Contact: NovaTech Europe BVBAKontichsesteenweg 712630 Aartselaar BelgiumT: +32 3 458.08.07F: +32 3 458.18.17Specifications Form C Relay Contacts Max. switching power 60W, 125VA Max. switching voltage 220 VDC, 250 VAC Max. switching current 2A DC or AC Max. carrying current 2A DC or AC Sonalert Audible Horn Loudness 80dbA min. Variable volume control in rear 12 Volt Alarm Power Supply (Required for Alarm Functions Only) Input Voltage Range 100 - 240 VAC, 47-63 Hz., 0.4A Output Voltage 12V at 1.25A max. USB 1.0/2.0 Compatible Data Exchange Rate 12 Mbps Current draw 100 ma. max. Supplied interface cable 3 meters PC Connector USB A Male Keyboard Connector USB B Male CE Certification Copy of certificate is available upon request. Installation CD Includes installation procedure and USB Drivers and Virtual COM Port Software for Windows 2000, XP, Vista, and Server 2003. Compatibility The D/3 USB Keyboard is compatible with all Windows OCMs supporting USB 1.0/2.0 connections. Keys Alphabetic Keys *, Q, W,E ,R, T, Y, U, I, O, P, &, DEL, @, A S, D, F, G, H, J, K, L, /, #, SPACE, Z, X, C, V, B, N, M, %, $, :, “, [, ] Numeric Keys 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 0, ., - Display Keys OVERVIEW, FACEPLATE, SINGLE LOOP, SYSTEM STATUS, GRAPHICS, GROUP LIST, LOOP MAINT, CURR TREND, HIST TREND Display Function Keys CLEAR, SAVE, DISPLAY EDIT, COPY, GENERAL FUNCTION, PAGE, PREVIOUS, GRAPHIC ASSOCIATION (4), ASSOCIATED DISPLAY, WINDOW SELECT Quick Select Keys 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 Alarm Keys ALARM P1, ALARM P2, ALARM P3, SILENCE, ALARM ACK, LAST ALARM Sequence Logic Keys UNIT STATUS, UNIT VARS, RECIPE STATUS, PROGRAM STATUS, PROGRAM STEPS, MESSAGE ACK, LOAD RECIPE, QUERY HOLD Digital Function Keys CLOSE OFF (CMD 0), OPEN ON (CMD 1), CMD #, OVERRIDE, MID IDLE (CMD 2), CLEAR FAULT Continuous Control Function Keys AUTO/MAN, SETPOINT, CASC, OUTPUT, VALUE, Ramp Keys: , , , Parameter Modification Keys CANCEL, MODIFY, SELECT, ENTER D/3® USB Keyboard Process Control Functions D/3 USB Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks are properties of their respective owners. D/3, SABL, and FlexBatch are registered trademarks of NovaTech Process Solutions, LLC. NovaTech is a registered trademark of NovaTech, LLC. The information in this literature is subject to change without notice and is not to be construed as a warranty. DS_USBKB_0607_A4 ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien