Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung MRV Communications, modell AE182FCAKA

Hersteller: MRV Communications
Dateigröße: 3.19 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


A separate power circuit shall be supplied and connected by a qualified electrician according to the wiring rules specified in the corresponding national standard. A current leakage breaker must be installed. The connection method of power cord is " Y " type. If the power flexible cord is damaged, it shall be replaced by the manufacturer or its service department or similar qualified technician so as to avoid risks. Power cord plug: L should be connected to the live wire, N should be connected to the neutral wire and to the ground wire. Connection wire size: 3 G (1.0-1.5) mm2, type of H05RN-F. Signal transmission wire size:H05RN-F 2 x (0.75-1.5) mm2 (shielded wire). Power cord, connection wire and signal wire shall be provided by the user. Indoor unit 1. Select suitable places the outlet air can be sent to the entire room, and convenient to lay out the connection pipe, connection wire and the drainage pipe to outdoor. 2. The ceiling structure must be strong enough to support the unit weight. 3. The connecting pipe, drain pipe and connection wire shall be able to go though the building wall to connect between the indoor and outdoor units. 4. The connecting pipe between the indoor and outdoor Fig 1 units as well as the drain pipe shall be as short as possible. (See Figure 1) 5. If its necessary to adjust the filling amount of the refrigerant, please refer to the installation manual attached with the outdoor unit. 6. The connecting flange should be provided by the user himself. 7. The indoor unit have 2 drainage outlet, one outlet be jamedwith rubber cap, during installation only use another outlet (In/Out liquid pipe side). When necessary, use the two outlet at the same time. 8. Not place the TV., equipment, facility, piano etc, expensive goods below the AC, prevent the water dropping down from the AC and lead to damage to the goods. 22 Installation Procedure After selecting the unit installation location, proceed the following steps: 1. Drill a hole in the wall and insert the connecting pipe and wire through a PVC wall-through tubepurchased locally. The wall hole shall be with a outward down slope of at least 1/100. (SeeFigure 2) 2. Before drilling check that there is no pipe or reinforcing bar just behind the drilling position. Drilling shall avoid at positions with electric wire or pipe. 3. Mount the unit on a strong and horizontal building roof. If the base is not firm, it will causenoise, vibration or leakage (see Figure 6). 4. Support the unit firmly. 5. Change the form of the connection pipe, connection wire and drain pipe so that they can go through the wall hole easily. Figure showing installation dimensions: (unit:mm) Model a b c d e f g i AE092FCAKA 615 648 452 225 55 125 225 100 AE122FCAKA AE142FCAKA 770 804 452 225 55 125 225 100 AE182FCAKA AE212FCAKA 990 1024 452 225 55 125 225 100 Fig 2 a i e f g b c d AE072FCAKA 223223 500 AE242FCAKA 1249 Notes 1.For electrical heating unit, the air outlet not allowed directly connecting with canvas etc. easy catching fire goods. 2.This series' indoor unit are all middle static pressure(30 Pa external static pressure ). 3.An access port must be provided during installation of indoor unit for maintenance. 23 Installation Procedure Installation of indoor unit When installing the ceiling concealed type indoor unit, a specially designed return airbellows shall be installed, as shown in Figure 3, Figure 4. A Installing building roof Ceiling Air supply Air outlet duct Unit Return air Return air bellows Figure 3 *0.5m or*5m Detail A Air outlet grille Air supply No obstacles within 1 m Unit Return air Return air bellows Figure 4 Each air return and supply duct should fix to the floor precast slab by using an iron stand. Use glue to seal the interface closely. Recommend the distance between the air return duct and the wall is more than 150mm. The distance between air duct outlet and air conditioner outlet is according to the length of actually installedair duct and in service behavior of the static pressure terminal: Installation sketch map for long and short airduct is showed below, when connect to short air duct, using low static terminal (terminal color is write), thedistance between air duct outlet and air conditioner outlet is no more than 0.5m; when connect to long air duct, using middle static terminal (terminal color is red), the distance between air duct outlet and air conditioner outletcould be within 5m at this point. air return shutter air return duct sling dog drain piping transition air duct air outlet duct air diffuser joint of air diffuser Figure 5 Drain piping of condensed water should keep a downhill grade of 1% or more. Use insulating pipe to coverthe drain piping of condensed water to keep warmth. As figure shown, suspend and install the unit. Figure 6 M8 suspension screw M8 broad lock ring M8 nut M8 broad foundation bolt Unit Figure 5 24 Installation Procedure Installation of indoor unit Installation for air duct of indoor unit 1. Installation for ...

Dieses Handbuch ist für folgende Modelle:
Schleifmaschinen - AE072FCAKA (3.19 mb)
Schleifmaschinen - AE092FCAKA (3.19 mb)
Schleifmaschinen - AE09~212FCAKA (3.19 mb)
Schleifmaschinen - AE122FCAKA (3.19 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien