Hersteller: HP
Dateigröße: 46.63 kb
Dateiname:
|
Anleitung Zusammenfassung
HP PCI Tachyon TL/TS/XL2 Fibre Channel Driver Release Notes
Defects Fixed in This Release
Defects Fixed in This Release
Table 1-2 lists the defects fixed in this release of the Fibre Channel PCI Tachyon XL2 driver.
Table 1-2
Defects Fixed
Number
Description
JAGag31993
Tachlite driver should be dynamically loadable
by default.
JAGag36171
The SNIA HBA Common library has been
moved from FibrChanl-00 bundle to
CommonIO bundle. The FibrChanl-00 bundle
now has a dependency on the Common IO
bundle.
JAGag38347
Unload of dynamically loadable Tachlite driver
causes system panic. Driver has been modified
to fix this problem.
JAGag39285
The post online delete operations should be
performed in the postremove control script for
FibrChanl-00 also.
JAGag07529
The link speed of an FC card shows up as
UNKNOWN when FC topology is changed from
direct connect to fabric within a time interval of
< 5 seconds.
JAGag26283
Target ports goes into NO_HW state after
switch zoning for HBA port is changed.
JAGag28394
A HBA reset followed immediately by a HBA
disable may lead to I/Os hanging in the Tachlite
driver.
JAGag31913
The legacy hardware path build routine should
not fail registration of other nodes upon an
overflow error from SCSI services.
JAGag40790
The SNIA library for Tachlite driver needs to
have support for autochanger luns.
JAGag41556
Upon failure in registering driver event
handler with services, Tachlite driver should
undo the load operation.
JAGag42086
When a Data Protector backup is initiated in a
SAN environment, system crashes with an
HPMC in the Tachlite driver.
14
Chapter 1
...Dieses Handbuch ist für folgende Modelle:
Netzwerk - HP-UX 11i v3 I/O Cards (46.63 kb)