Anleitung Zusammenfassung


Table 3 HP-UX March 2011 (AR1103) Fixes
Defect ID
Description
QXCR1001043163
The IB4X-00 driver is enhanced to support the InfiniBand QDR Mezzanine card 512519–B21
on HP Integrity blade servers.
QXCR1001064478 The IB4X-00 driver is enhanced to support the InfiniBand QDR Standup card AT083A on
Superdome 2 and rx2800 i2 systems.
Table 4 HP-UX August 2010 (WEB1008) Fixes
Defect ID
Description
QXCR1001043163
The IB4X-00 driver is enhanced to support the InfiniBand QDR Mezzanine card 512519–B21
on HP Integrity blade servers.
QXCR1001031504
The nettl message logs as an ERROR, when the processing time of an event exceeds the allowed
time; therefore, it needs to be changed to WARNING.
Table 5 HP-UX March 2010 (AR1003) Fixes
Defect ID
Description
QXCR1000968186 Opening device file resulted in a system panic. This occurred regardless of
whether or not the IB adapter was installed. This problem has now been fixed.
Table 6 HP-UX September 2009 (WR0909) Fixes
Defect ID
Description
QXCR1000940168 The DART81 BA929AA 11iv3 VSE OE software with InfiniBand adapter 448397-B21 failed to
boot at the ESWL_IGNITEUX stage, due to timeout at iux_monitor_reboot. The driver code
has been modified to resolve this issue.
QXCR1000946862 The new ituil command option, x, has been provided to display the link speed of an InfiniBand
interface.
QXCR1000938720 In the cluster environment, where HP-UX and Linux nodes are connected to the switch, whenever
the HP-UX node reboots, there is an LID change at the HP-UX node, which is non-compliant with
InfiniBand subnet manager protocol.
QXCR1000938766 The PM subsystem in the InfiniBand driver is not responding to ClassPortInfo requests. For
this reason, some of the Linux/OFED tools generate an error when there is an HP-UX host in the
cluster. The tools affected are:
ibcheckerrs
ibcheckerrors
ibdatacounters
ibclearcounters
ibclearerrors
QXCR1000962014 There is a shutdown error during CVA, due to an issue with the RDMA/InfiniBand Driver Control
Script.
Table 7 HP-UX September 2009 (AR0909) Fixes
Defect ID
Description
QXCR1000914516
RDS: socket descriptor leak in rdmad
QXCR1000925537 RDS: application crash in rds user library
Table 8 HP-UX March 2009 Fixes
Defect ID
Description
N/A
There are no known problems fixed in this version of the IB4X-00 driver.
Known problems fixed in this version