Anleitung Allied Telesis, modell AR44xS series
Hersteller: Allied Telesis Dateigröße: 432.35 kb Dateiname: 39ea0ee7-bdb7-0764-b9e7-c5f04f971383.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
These issues have been resolved. Y - Y Y Y Y Y - - - CR00012868 ENCO 2 Entering the command create enco key= number ip= ? caused the router or switch to reboot. This issue has been resolved. Y - Y Y Y Y Y - - - CR00012951 IPv6 2 RIPng ( for IPv6) sometimes sent sub- optimal routes to its neighbours. When RIPng was configured in a network with loop topology, this could cause unstable routing table entries on the neighbours ( the metric kept being updated, as a result of updates from neighbours) . This issue has been resolved. RIPng no longer sends sub- optimal routes. Y - Y Y Y - - - - - Version 276- 05 C613- 10474- 00 REV D Features in 276- 04 CR Module Level Description AR44xS/ AR450SAR7x5AR750SRapier iAT-8800AT-8600AT-8700XLAT-8948AT-9900AT-9800 CR00012952 Bridge 2 If a tagged packet was bridged out of a VLAN interface, the interface always added a VLAN tag into the packet, even though the packet was already tagged. This issue has been resolved. Y - Y - - - - - - - CR00012991 ATM 2 The maximum allowed value of the vpi parameter in the commands add and set atm channel has been increased from 8 to 15. Y - - - - - - - - - CR00013023 OSPF 2 An issue occurred when OSPF was configured to create passive interfaces by default ( set ospf passiveinterfacedefault= on) but an OSPF interface was not passive ( set ospf interface= interface passive= off) . This interface setting was saved in the configuration file or output resulting from the commands create config and show config dynamic, but any other changes to interface settings were not saved ( such as changes to authentication settings). If the router or switch rebooted, these other interface changes were lost. This issue has been resolved. Y - Y Y Y Y Y - - - CR00013077 IPv6 2 When an IPv6 address was deleted on the router or switch, and that IPv6 address had previously been learnt by a remote IPv6 node, then the router or switch would reboot if it received an ICMPv6 Neighbour Solicitation message from the remote node. This meant, for example, that if you successfully pinged an address on the router or switch, then deleted that address, then attempted to ping the old address again, the router or switch would reboot. This issue has been resolved. Y - Y Y Y - - - - - CR00013081 Switch, STP 2 When STP was enabled on ports in a trunk group, the non- master ports did not have the same state as the master port in the switch’s hardware STG table. This could, on rare occasions, create a broadcast storm. This issue has been resolved. All ports in a trunk group follow the master port in the hardware STG table. - - - Y Y Y Y - - - Version 276- 05 C613- 10474- 00 REV D Features in 276- 04 CR Module Level Description AR44xS/ AR450SAR7x5AR750SRapier iAT-8800AT-8600AT-8700XLAT-8948AT-9900AT-9800 CR00013083 TACACS+ , User 2 After a very large number of successful logins via TACACS+ authentication, the router or switch would reboot. This issue has been resolved. Y - Y Y Y Y Y - - - CR00013096 CR00013718 IPv6 2 When the router or switch learned a better IPv6 route to exactly the same destination as an existing route, the router or switch did not always change existing data flows so that they used the new route. This meant that existing flows did not always follow the optimal path. This issue has been resolved. When the router or switch learns a better IPv6 route, both new and existing flows now use it. Also, the commands create ipv6 interface and set ipv6 interface now include a new parameter: metric. This allows you to set the RIP metric of link local interfaces to a desired value. Note that the metric parameter is only valid on link local interfaces. Y - Y Y Y - - - - - CR00013234 IP Gateway 2 If the router or switch attempted to email log output, and used a domain name server that gave a non- standard response to the DNS query, the router or switch sometimes rebooted. This issue has been resolved. Y - Y Y Y Y Y - - - CR00013276 UPnP 2 In UPnP, Msearch requests were stored indefinitely, which eventually exhausted the router’s memory and caused it to reboot. This issue has been resolved. Msearch requests are now deleted once the router has finished with them. Y - Y - - - - - - - CR00013309 L2TP 2 When an L2TP LAC Client (for example, a Microsoft Windows XP VPN Client) activated an L2TP tunnel to a router or switch that was operating as an LNS, the dynamic PPP interface on the LNS left out the PPP authentication phase. This also prevented the interface from obtaining an IP address by remote IP assignment from a User Database entry. This issue has been resolved. Y - Y Y Y - - - - - Version 276- 05 C613- 10474- 00 REV D Features in 276- 04 CR Module Level Description AR44xS/ AR450SAR7x5AR750SRapier iAT-8800AT-8600AT-8700XLAT-8948AT-9900AT-9800 CR00013437 SCC 2 If a PRI or BRI interface had severe transmission difficulties due to a faulty communications link, it could cause the router or switch to reboot. This issue has been resolved. A faulty PRI or BRI communications link can no lo...