Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Altinex, modell MT105-110

Hersteller: Altinex
Dateigröße: 881.85 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


7.1.1 RS-232 INTERFACE The RS-232 commands for the MT105-110/111 are in a simple ASCII character format 1. Square brackets “[ ]” are part of the command. 2. Use uppercase letters for all commands. After processing a command, an OK or ER string will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero. Commands such as [ON], [OFF], and [IO] that end in "S" will be saved into memory. Commands not ending in "S" will still be executed but will not be restored when the system is reset (power off & power on again). 7.2 DESCRIPTION OF COMMANDS Each command consists of three parts: function, card ID, and unit ID. [Function, Card ID, Unit ID Example: [VERC3U2] VER = function C3 = Card ID U2 = Unit ID For function, see a detailed explanation under each command description. Card ID is an assigned value from 1 to 19 (1 to 8 or 1 to 2 depending on which enclosure is being used); based on which slot the card is put in. Card ID 0 (C0) is used for the controller (see user’s guide for the MT100-100). Changing the position of a card will significantly affect the commands recorded on software definitions or a third party control system. Unit ID has a value from 0 to 9. Unit ID 0 should be used for single unit operation. If the Unit ID is set to 0, then each command can be used without Ui (use command [SETU0]; see user’s guide for the MT100-100). Example: [VERC3]: for unit ID zero [VERC3Ui]: for unit ID other than zero [VERC3]: equivalent to [VERC3U0] 1. [VER] This command displays the software version and card type for the MT105-110/111 card Command Format: [VERCnUi Cn = card ID (n = slot # from 1 to 19) Ui = Unit ID (i = # from 0 to 9) (refer to the MT100-100 user’s guide for explanation 8 MULTI-TASKER Example: If one MT105-110/111 card is in slot #2 of unit 3: When sending command [VERC2U3], the Multi- Tasker™ Enclosure will return feedback as MT105-111 690-0126-011. 2. [C] This command displays the status of the card and connections of the Matrix Switcher. Command Format: [CnUi] Cn = card ID (n = a slot # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) Ui = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation) Example: If one MT105-110/111 card is in slot #2 of unit 3 with output 1, 2 and 3 ON: When sending command [C2U3], feedback will be returned as: Config:16X8 In1 Out1 ON In2 Out2 ON In1 Out3 ON In2 Out4 OFF In8 Out5 OFF In7 Out6 OFF In10 Out7 OFF In16 Out8 OFF Description of Feedback: Input1 is connected to Output1 and Output1 is enabled Input2 is connected to Output2 and Output2 is enabled Input1 is connected to Output3 and Output3 is enabled Input2 is connected to Output4 and Output4 is disabled Input8 is connected to Output5 and Output5 is disabled Input7 is connected to Output6 and Output6 is disabled Input10 is connected to Output7 and Output7 is disabled Input16 is connected to Output8 and Output8 is disabled Note: If there is no card in slot #2 of unit 3,sending the [C2U3] command will not return any feedback. ERROR CODES ER01: CPU Error This type of error indicates that the CPU is not working properly. ER02: I.C Communication Error This means that the communication between the MT105-110/(111) card and its serial device has failed. ER03: RS485 Communication Error This type of error is a communication error between the MT105-110/(111) card and the controller of the Multi-Tasker™ Enclosure. [CiS] This command saves card status such as ON/OFF, IN/OUT connection as default settings 3. [IO] This command will connect input x with output y, but the user needs to use the [ON] command to enable this output. Command Format: [IxOyCnUi] 9 MULTI-TASKER Ix = select input x (x is # from 1 to 16) Oy = connect to output y (y is # from 1 to 8) Cn = card ID number (n is # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) Ui = unit ID, i is # from 0 to 9). (Refer to MT100100 user’s guide to set Unit ID). S = saves command to memory Example: To connect input 4 to output 2 (card 2 of unit 3), use the [I4O2C2U3] command. [ImO*…]. This command connect input m to all outputs. 4. [ON] This command enables one or more outputs of a single card or a group of cards [ONmCnUiS]: for a single card This command enables output “m” without affecting any other outputs. Default when plugged in = ALL OFF m = Output number (m = 1 to 8) n = Card ID number (n = 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) i = Unit ID number (i = 0 to 9) S = saves command to memory Example: 1) [ON12C5U3]: Turns ON only output 1 and 2 of the MT105-110/(111) card located in slot #5 of the MT100-100 Enclosure with unit ID3. 2) [ON3C5U3]: Turns ON only output 3 of the MT105-110/(111) card located in slot #5 of the MT100-100 Enclosure with unit ID3. After the [ON12C5U3] and [ON3C5U3] commands have been executed, output 1, 2 and 3 will be ON. 3) [ONC5U3]: Turns ON all outputs of the card. [ONmGkUiS]: for a group of cards This command enables output "m" for each card in group...

Dieses Handbuch ist für folgende Modelle:
Netzwerk - 400-0226-003 (881.85 kb)
Netzwerk - MT105-111 (881.85 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien