Anleitung Zusammenfassung


A NAMUR amplifier with a relay output can be supplied as an optional element. OPERATION The indicator needle moves together with the vane mounted on its shaft. When the vane enters into the slot of the detector, the limit switch changes its state. The detector, is mounted on a support which includes an indicator on the scale, that shows the switching position. This support is guided by the scale plate slot. SWITCHING POINT ADJUSTMENT To gain access to the limit switch inside the indicator housing, remove the front cover held by four M4 x 8 DIN 7985 (Philips) screws. To move the limit switch indicator, the fixing screws have to be slightly loosen (figure 2). After that, place the limit switch indicator in the required scale value, and fix it with the two screws. As standard, when the instrument has only one AMD, it comes configured as a minimum limit switch. In the case of two AMD, one of theme is for minimum and the other is for maximum. To change the standard configuration, refer to MAINTENANCE section. ELECTRICAL CONNECTION For the electrical connection, the instrument is provided with a for terminal connector. Before starting the installation, check that the cable gland of the connector (PG7) is the right size for the cable to be used, this will guarantee the instrument will stay watertight (it is recommended to use multiple conductor cables with external diameter sections from 4 to 7.5 mm, with individual cable sections in the order of 0.25 mm2). Loose cables should not be used given that they can affect the seal of the cable glands. Before wiring, disassemble the connector, removing the head, and unscrewing the cable gland. Remove the rubber seal and the washer. After that, slide de cable through the cable gland nut, through the washer, through the rubber seal and finally through the connector head. Strip the outside insulation of each conductor to free the inner wires so that once they are soldered in, the end of the outside insulation of the cable will just pass through the cable gland. It is recommended to tin the ends of the wires to avoid loose ends. Solder the two wires as shown in the figure of the following page. Before assembling the connector, make sure that the position is such that the cable comes out at the bottom). After that, tighten up the cable glands so that they maintain their degree of protection. 2 Figure 2 Limit switch indicator Figure 1 In some instruments such as some models of ADI series, instead of having a connector, there is a cable gland with a cable with three colours (brown, blue and green/yellow). In this case the connections should be made as follows: Green/yellow = Earth Brown = + Blue = - MAINTENANCE 1 32 No connection _ (Blue) + (Brown) Earth 1. Change of the vane position respect the limit switch AMD-MAXIMUM Place the limit switch indicator in the required scale value, fixing it by means of the 2 screws. After that, move manually the shaft that supports the indicator needle, until the indicator needle coincides with the maximum limit switch indicator. After that, loosen the grub screw (1.5 mm Allen key) of the vane and make point 1 coincide with the centre of the detector ( Figure 3 ). Tighten the screw to fix the vane. AMD-MINIMUM The process is the same as for the maximum point, but making the point 2 coincide with the centre of the detector ( Figure 4 ). 2 1 1 2 Figure 3 Figure 4 In the event that the instrument has two limit switches, the working range will be limited to the following values: From 0 to 25% of the scale, for the AMD of the minimum limit switch. From 75 to 100% of the scale, for the AMD of the maximum limit switch. 2. Electrical verification of the limit switch a) Check that the voltage at the terminals 1 and 2 is over 7.5 V when the vane is in the slot. Connect a multimeter with the scale in DC mA, in series with the terminal 2. b) Verify that the current is less than 1 mA when the vane is in the slot, and more than 3 mA when the vane is out of the slot. If you don’t have the NAMUR amplifier, the current can be checked using the following circuit diagram: AMD + - 1 k.+ - 2 1 9V Battery (8.2V Nominal for NAMUR ) Multimeter mA +- If you don’t have the detector, the operation of the amplifier can be checked using the following circuit diagram: Potentiometer 20 k. With the potentiometer we modify the current of the NAMUR amplifier. The switching point must be between 1.2 mA and 2.1 mA. That is, with the current below 1.2 mA the output relay must have a state and above 2.1 mA the output relay must have the other state. Amplifier + + - -Multimeter mA NAMUR Connection TECHNICAL CHARACTERISTICS The AMD is a NAMUR (DIN 19234) sensor with the following nominal characteristics: Nominal voltage 8.2 V Power supply internal resistance 1 k. Current with the vane into the slot < 1 mA Current with the vane out of the slot . 3 mA Power supply limits 5 ... 25 VDC Ambient Temperature -25 ... +100 .C Self inductance 160 .H Self capacity 20 nF Conforms with the Direct...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien