Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Adder Technology, modell EPOWERSWITCH 8XM

Hersteller: Adder Technology
Dateigröße: 202.29 kb
Dateiname: 23296de7-0f58-43d6-9738-0a3ecd1a4f65.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


It includes also many monitoring functionalities and supports SNTP and SMTP protocol. ePowerSwitch 8XM Master Technology House -Trafalgar Way Bar Hil -Cambridge -UK CB3 8SQ Tel:+44 (0)1954 780044 -Fax:+44 (0)1954 780081 High security ePowerSwitch supports https (SSL) protocol Zone de Texte: ePowerSwitch ..Advanced SecurityFor your security, account access and data transfer are encrypted with SSL Technology. ..Multiple concurrent usersAllows multiple concurrent user access to the Master and all Satellites. Each user has access to control his designated power outlets. ..DHCP clientReduces configuration management. ..Scheduler for Time-Controlled ApplicationsThis time-controlled function lets you control Power Outlets and dry Contacts and also allows to send Emails. ..IP device monitoringEnables to monitor IP devices using PING and Scan functions with automatic reboot in case of lock-up of the monitored device. ..Temperature and Humidity monitoringThis function lets you monitor temperature and humidity in racks or server rooms. If thresholds are exceeded, Power Outlets can be automatically switched off, dry contacts controlled and Email sent. ..Improved log file reportingMore information enables to help in troubleshooting. ..Programmable LabelsA 32-character label can be attributed to each connected device to avoid confusion during operation. ..Easy ConfigurationFull configuration can be performed through the LAN using a very convenient Windows tool (can be disabled) or through the Web using the Web GUI. Features ..Remote Power ManagementEach power outlet can be turned On/Off or restarted over IP.The number of controlled outlets can be extended up to 136 by cascading 16 Satellite models. ..Two separate AC Power InputsTo improve the security and increase the total current load the ePowerSwitch 8XM supports dual Power Inputs (up to 10 Amps each). The first one provides power for outlets 1 to 4 and the second one for outlets 5 to 8. This feature is ideal for power management of servers with redundant power supplies. ..Power Outlet ExtensionUp to 16 ePowerSwitch Satellites can be connected to a Master to control up to 136 Power Outlets. ..Power Outlet GroupingEnables to group individual outlets from the Master and different Satellites. Ideal to control multiple power supply servers & devices with a single command. ..Power-up Sequencing: Avoids the risk for a power in-rush to blow a fuse or circuit breaker in the data center. ..Restart DelayThis delay, which applies to the restart activity at all power outlets, can be chosen between 5 and 60 seconds between off/on. ..Access and accountsThe administrator password allows configuration and control of all power outlets. The administrator also can create up to 255 user accounts withaccess rights only to designated outlets. Technical Features What’s included ..1 EPS 8XM XX (XX specifies delivered power cables, see below) ..2 power cables IEC-320-C13 to XX (EU = Schuko/Europe standard, CH =Swiss standard or UK = British standard) 1.80 Meters ..1 serial cable (SUB-D9 male/female) 1.80 Meters ..1 CD-ROM containing User Guide in English and IP Configuration Tool Accessories Horizontal Rack mounting kit with cable fastening ..Part-Nr.: EPS-CABMAN Power Cable 230 V / 10 A ..United Kingdom standard ..British BS1363A to IEC-320 C13 ..1.80 Meters, Black, Part-Nr.: 80.90.10 Power Cable 230 V / 10 A ..Schuko/Europe standard ..Schuko CEE 7/EU1-16P to IEC-320 C13 ..1.80 Meters, Black, Part-Nr.19.99.1018 Benefits ..Remote individual control of up to 136 power outlets ..Dual power inputs allows increasing total load and security ..Outlet Grouping allows controlling multiple power supply servers and devices ..Power-up sequencing avoids in-rushes currents at start-up ..IP device, temperature and humidity monitoring ..Programmable restart delays and labels ..Access protected by names and passwords ..Firmware upgrade over the LAN for future product enhancements Front side / Back side A seris of front-panel LEDsprovide quick status checks. 2 separate AC inputs alow power managing of devices with redundant power supply and a total load of 20Amp / 230V. Power Cable 230 V / 10 A ..Swiss standard ..Swissto IEC-320 C13 ..1.80 Meters, Black, Part-Nr.: 19.08.1220 Power Cable230 V / 10 A ..IEC-320 C14 male to IEC-320 C13 female ..1.80 Meters, Black, Part-Nr.: 19.99.1515 Vertical rack mounting kit ..Part-Nr.: EPS-RACKMOUNT Network standards IEEE 802.3, 10 / 100 BASE-T Network protocols TCP/IP, HTTP Network connection RJ-45 connector for UTP CAT5 Max. network cable length 100 meters (not included) Serial connection RS232, SUB-D 9 female SSL Technology Version 2 and 3 Nominal input voltage 230 V/50Hz Input power socket IEC-320 Output voltage 230 V/50Hz Output power socket IEC-320 Maximum total current 2 x 10 A LEDs 1 for Power Supply A 1 for Power Supply B 8 for the Power Outlets status 4 for Dry Contacts Output Status 1 for Network traffic 1 for Network Speed 10 / 100 Mbits/s Ope...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien