Before drilling the lower hole pay attention if hot and/or cold water supply pipes cross this area. KW = cold water WW = hot water ." connection ." connection Shower tray floor Shower tray floor Panel Dimensions The panel is movable 8" downward. The stated dimensions refer to the highest position of the panel. Fittings / Technical Data Overhead shower Aluminium profile Tray Bodyshower Thermostat grip Shut-off/selection valve Handshower Shower hose Technical Data Minimum flow pressure 29 psi Operating pressure max. 147 psi* Recommended operating pressure 29.4-73.5 psi Test pressure 235.2 psi Hot water temperature max. 158 °F Safety stop 100 °F Flow capacity at psi Hand shower (1) 1,9 gpm Body showers, 6 jets (2) 3,9 gpm Overhead shower 2,8 gpm Overhead shower + body showers (3) 5,5 gpm Hand + body showers 5,0 gpm Flow heater: Applicable for flow heaters at min. 24 kW and 29 psi flow pressure before the Shower panel. Only one consumer possible, not two simultaneously. Pressure differences: The pressures of the cold and hot water connections must be balanced. Maintenance The non return valves must be checked regularly according with national or regional regulations (at least once a year!). * Check applicable codes The flow rates are limited to .5 gpm. These are the maximum flow rates permitted by the From • the function is guaranteed. Fitting Items / Water Connections Overview Wall Installation 7 Seal all drill holes with silicone free from acetic acid (not in scope of delivery) Fitting items / water connections wall installation Before drilling the bottom holes pay attention if hot and/or cold water supply pipes cross this area. In this case, only drill on the side without any supply pipes. Dimensions The installation dimensions stated in this installation instructions are ideal for people of approximately 70" in body height. The dimensions can be altered if required. In this case you will have to attend to the minimum height of 87" from shower tray floor, and alter all the required measurements as necessary. If the height of water connection are outside of the illustrated range, the drill measures have been adjusted accordingly. (attention for minimum room height of 87 from tub-floor) Flush through the supply pipes. SW 0 mm SW mm O 0 mm O8 mm SW 24 mm 1 2 1. 2. 1. 2. Wall Installation 3 4 SW 13 mm SW 2 mm Wall Installation Adjustment Thermostatic mixer please see page 14 Fitting Items / Water Connections Overview Corner Installation 0 2x 2x 2x1x Seal all drill holes with silicone free from acetic acid (not in scope of delivery) Fitting items / water connections corner installation Before drilling the bottom holes pay attention if hot and/or cold water supply pipes cross this area. In this case, only drill on the side without any supply pipes. Dimensions The installation dimensions stated in this installation instructions are ideal for people of approximately 70" in body height. The dimensions can be altered if required. In this case you will have to attend to the minimum height of 87" from shower tray floor, and alter all the required measurements as necessary. If the height of water connection are outside of the illustrated range, the drill measures have been adjusted accordingly. (attention for minimum room height of 87 from tub-floor) Flush through the supply pipes. SW 5 mm O mm SW 0 mm O mm SW mm 11 1 2 3 Corner Installation 12 4 5 SW 24 mm 1. 2. 1. 2. Corner Installation 13 6 7 SW 13 mm SW 17 mm Corner Installation Adjustmen...

Dieses Handbuch ist für folgende Modelle:
Plumbing - Pharo DP Lift 2 M 20 (2.32 mb)
Plumbing - Pharo DP Lift 2 M 20 (2.32 mb)
Plumbing - Pharo DP Lift 2 M 20 (2.32 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien