Login:
Stimmen - 1, Durchschnittliche Bewertung: 5 ( )

Anleitung Hans Grohe, modell SELECTRONIC 6065.525

Hersteller: Hans Grohe
Dateigröße: 1.01 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Make sure SEAL WASHER (3) and FRICTION WASHER (4) are installed. Do not tighten fully. 3. Insert the DOWN TUBE (5) into the SPUD COUPLING NUT (2) and push it down. Note: If cutting Down Tube (5) to size, note that Critical Line (C/L) on Vacuum Breaker must typically be 6" (152mm) above fixture. Consult Code for details. Fig.3 CENTER LINE OF FIXTURE SPUD FINISHED WALL FILE EDGES SOLDER ADAPTER ADAPTER 32mm (1-1/4) A (A-B)= BC CLEAN Fig. 4 Fig. 4a Fig. 4b Fig. 4c 1 1 4 2 3 TEFLON TAPE FINISHED WALL X X2 1 2 5 Fig. 5 3 4 1-1/2" TOP SPUD M968699 Rev. 1.14 3 FLUSH OUT SUPPLY LINES; Fig. 6 Fig. 6 1. Remove COVER (1) from SUPPLY STOP (2). 2. With a flat blade screwdriver open SUPPLY STOP (2). 3. Turn on water supply to flush line of any debris or sediment. 4. Close SUPPLY STOP (2) and replace COVER (1). 1 CLOCKWISE CLOSES CONTROL STOP COUNTER-CLOCKWISE OPENS CONTROL STOP REMOVE COVER 2 2 45LEFT OR RIGHT HAND INSTALLATION; Fig. 7 The UNIT is shipped with the inlet flange on the right side. If needed, the orientation can be reversed by following the steps below. 1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (4) in back of top half of FLUSH VALVE (2). Fig. 7a. 2. Rotate TOP (2) to the right and pull off. Fig. 7b. 3. Rotate bottom half of FLUSH VALVE (3) 180°. Fig. 7b. 4. Replace TOP (2) and rotate until key engages than tighten SET SCREW (1). Fig. 7c, 7d. 4 M968699 Rev. 1.14 1 4 Fig. 7a Fig. 7c Fig. 7d Fig. 7 4 KEY 2 2 1 3 Fig. 7b 180° RED+ BLACK- 2 INSTALL FLUSH VALVE; Fig. 8a Fig. 8a & 8b 1. As shown in Fig. 8a, insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 8a. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape. 2. Align the FLUSH VALVE (2) (Fig. 8b) directly above the DOWN TUBE (7) and VACUUM BREAKER COUPLING NUT (6). Make sure that GASKET (10) is installed. Note: There is a +13mm, -6mm (+1/2, -1/4) tolerance for the 121mm (4-3/4) dimension. Fig. 8b. 3. Pull the DOWN TUBE (7) up to meet the threaded 3 2 5 1 4 FLUSH VALVE CONNECTION (8) and hand tighten the VACUUM BREAKER COUPLING NUT (6). Align all components of the flush valve assembly. Fig. 8b. 4. Lightly tighten the COUPLING NUT (5) connection first, then the VACUUM BREAKER COUPLING NUT (6) and finally the SPUD COUPLING NUT (9). Once alligned correctly, use a wrench to tighten couplings to make water tight connections. Fig. 8b. 7 ADJUST SUPPLY STOP; Fig. 9 IMPORTANT: To avoid overflowing, the SUPPLY STOP (3) must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture.The fixture must be able to handle a continuous flow in case of a flush valve failure. 1. After installation is complete, peel off the PROTECTIVE FILM (1) from the sensor. Standing to one side, block the sensor with your hand for 10 seconds. Remove your hand and listen for audible “click” from within the valve. 7 ...

Dieses Handbuch ist für folgende Modelle:
Plumbing - SELECTRONIC 6065.121 (1.01 mb)
Plumbing - SELECTRONIC 6065.122 (1.01 mb)
Plumbing - SELECTRONIC 6065.122 (1.01 mb)
Plumbing - SELECTRONIC 6065.121 (1.01 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien