|
Anleitung Zusammenfassung
- The remaining water does not mean that the product was previously used. Tips Uninstallation Existing Toilet Seat 1. Remove the fixing nuts of the existing seat and separate the existing toilet seat 1 and the seat cover 2. . Keep the removed seat and the removed seat cover in a shaded place. Installation the Product 1. Turn off the main water supply valve 1 on the water pipe and separate the existing water tank hose 2. 2. Connect the rubber packing, T-shaped connector, and water tank hose to the existing main water supply pipe. Please connect the bidet hose to the T-shaped connector. . Please insert the rubber packing between the water pipe and the T-shaped connection pipe necessarily. . Firmly rotate the nuts below and on top of the T-shaped connector to the end clockwise. 3. Please assemble by turning the MF filter on the filter holder to the arrow direction as the figure. . If the filter is assembled loosely, the bidet may not function normally. Firmly connect the filter. 4. Please connect the filter assembled the filter holder in the rear of the product and fix using the filter clip. Check if the filter clip is inserted correctly. When the main water supply valve is opened, if the filter clip is loosely fitted, as the filter holder may be separated, the water may splash and it may cause injury. It is not possible to separate the filter clip once it is fitted to the product. When the problem occurs due to the filter clip, call the service center. 12 INSTALLATION | Uninstallation Existing Toilet | Installation the 12 INSTALLATION Installation the Product 5. Push fixing screw into the fixing slider. And slide the fixing slider with fixing screw to be hooked in the installation boad. 6. Insert fixing screw into the holes and pushfixing rubber, fixing washer into the fixing screw to prevent from wobbling of the main body. Then tighten up the fixing nuts. If you do not tighten nuts. It may cause injury or damage to customer. 7. Please connect the bidet hose to the filter fixing stopper. . Please shorten the bidet hose as soon as possible. If the bidet hose is long, it may cause noises. 8. Open the main water supply valve. 9. Connect the power plug to the electrical outlet. . Make sure to use a grounded electrical outlet. In the case of short circuit, grounding prevents electric shock or injury. Make sure to use a dedicated electrical outlet with grounding terminals. If it is unavoidable to use an extension cord, use one with grounding terminals for power rating of 125 V~, 7 A or higher. Grounding terminals Installation the Remote Control Mount 1. Remove the fixing screw (O 6) that fixes the remote control mount on the bottom of the bidet. 2. Remove the remote control mount from the bidet. 3. On the opposite side of the remote control mount rotation axis, remove the screw that fixes the axis and the cover-axis. 4. Remove the cover-axis from the remote control mount. . This installation method was explained on the basis of the case installed the remote control mount for the right hand. . After removing the fixing screw and separating the product form the toilet, separate and install the remote control mount. Tips INSTALLATION | Installation the | Installation the Control Mount INSTALLATION Installation the Remote Control Mount 5. Insert the rotating axis in the opposite side after pulling out it from the remote control mount. . Insert the axis with the thicker part facing the back of the remote control mount. 6. Insert the cover-axis in the hole on the opposite side of the rotating axis. . Align two projections with the two grooves on the axis when inserting the cover-axis. 7. Fix the rotation axis and the cover-axis with a screw. Please tighten the cover-axis firmly. If the screw is loosely assembled, the remote control mount may be separated and is dropped, which may cause product damage or a bodily injury. 8. Please separate the rubber stopper from the opposite side of the bidet installed the remote control mount before. . Please be sure to insert the separated rubber stopper to the opposite remote control mount fixing groove. Otherwise, the product may break. 9. Insert the rotation axis of the remote control mount and fix the remote control mount with the fixing screw (O 6) on the bidet bottom. Please tighten the fixing screw (O 6) firmly. If the screw is loosely assembled, the remote control mount may be separated and is dropped, which may cause product damage or a bodily injury. CLEANING METHOD Nozzles 1. Press nozzle cleaning button on the right side of the bidet. The nozzle cleaning water is sprayed and the front cleansing nozzle sticks out to its full length. Clean the front cleansing nozzle. 2. Press nozzle cleaning button one more. - The nozzle cleaning water is sprayed and the front cleansing nozzle retracts itself, and the rear cleansing nozzle sticks out to its full length. - Clean the rear cleansing nozzle. 3. If you press the stop button on the remote control or nozzle cleaning button on the pr...
Dieses Handbuch ist für folgende Modelle:Plumbing - BA08-AE (15.89 mb)