|
Anleitung Zusammenfassung
Main water supply to the unit should be ON at all times. This installation manual and parts list should be filed by the owner’s maintenance department. Installation Instructions WF2605, WF2608 Terrazzo WF2705, WF2708 Stainless Steel Classic Circular 36"/54" Washfountain with Foot Control 215-603 Rev. M; EN 06-915B © 2007 Bradley Corporation Page 1 of 28 4/6/2007 P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY FAX 262-251-5817 Table of Contents Pre-Installation Information . . . . . . . . . . . . . . . . . 2 Circular Washfountain Dimensions . . . . . . . . . . 3-4 Rough-In Specifications . . . . . . . . . . . . . . . . . . . 5-6 Drain Rough-In Specifications . . . . . . . . . . . . . . . .7 Pedestal Mounting and Assembly . . . . . . . . . . . . .8 Bowl and Pedestal Assembly and Mounting . . . . .9 Drain Spud Installation . . . . . . . . . . . . . . . . . . . . .10 Supplies w/Optional Soap Dispenser (A/O drains) . .11-12 Supplies w/Optional Soap Dispenser (B/H drains) . .13-14 Installing the Valve Assembly . . . . . . . . . . . . . . .15 Installing the Operating Rod . . . . . . . . . . . . . . . .16 Soap Valve Maintenance and Repair Parts . . .17-18 Check Valve Troubleshooting . . . . . . . . . . . . . . .17 Stop, Strainer and Check Valve Repair Parts . . . .19 Sprayhead Troubleshooting/Repair Parts . . . . . . 20 Foot Valve Breakdown and Repair Kit . . . . . . . .21 Manual Mixing Valve Repair Parts . . . . . . . . . . .22 Volume Control Valve Repair Parts . . . . . . . . . . .23 Vernatherm™ Mixing Valve Maintenance . . .24-26 Cleaning and Maintenance Instructions . . . . .27-28 WF2605 WF2708 UPC Certified U PC R C Classic Circular 36"/54" Washfountain with Foot Control WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel Installation Instructions Pre-Installation Information Operation Stepping on the foot rail allows the user to activate a valve starting the flow of water. Supplies required for installation: • (8) 1/2" lag bolts, screws or other fasteners to anchor washfountain pedestal to floor • 1" hot and cold water supply lines and fittings (refer to rough-ins on pages 5-6) • Reducing fittings and 1/2" nom. copper tubing supply lines for types with supplies from above • 2" drain lines and fittings (refer to rough-ins on pages 5-6) • Standard 2" P-trap (refer to rough-ins on page 7, special vented trap supplied for B and H type) • Pipe sealant and plumber’s putty • 1-1/2" vent pipe on types vented through washfountain column (refer to page 4 for lengths required) NOTE: Supply lines for one or two washfountains should be 1"; for three washfountains 1-1/4"; for more than three washfountains pipe size should increase proportionally. Vent pipe to be 1-1/2" on models vented through Washfountain. Bradley Classic Washfountain Warranty Information Product warranties may be found under “Product Information” on our website at 4/6/2007 Bradley Corporation • 215-603 Rev. M; EN 06-915B Classic Circular 36"/54" Washfountain with Foot Control Installation Instructions WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel Circular Washfountain Dimensions F H G A B C D E Approximate Dimensions in Inches* Material Size A B C D E F G H Terrazzo 54 19 29-1/4 39-1/8 47-5/8 56 32 36 54 Stainless Steel 54 19 28 37-3/8 45-7/8 54-1/4 32 36 54 Terrazzo 36 19 29-1/4 35-5/8 44-1/8 52-1/2 21 25 36 Stainless Steel 36 19 28 33-7/8 42-3/8 50-3/4 21 25 36 * Juvenile height (Terrazzo only): Subtract 4" from dimensions A through E for juvenile height. Approximate Dimensions in Millimeters* Material Size A B C D E F G H Terrazzo 1372 483 743 994 1210 1422 813 914 1372 Stainless Steel 1372 483 711 949 1165 1378 813 914 1372 Terrazzo 914 483 743 905 1121 1334 533 635 914 Stainless Steel 914 483 711 860 1076 1289 533 635 914 * Juvenile height (Terrazzo only): Subtract 4" from dimensions A through E for juvenile height. Bradley Corporation • 215-603 Rev. M; EN 06-915B 4/6/2007 Classic Circular 36"/54" Washfountain with Foot Control WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel Installation Instructions Length of Tie Pipe Required for Vent Through Washfountain Column Type Pipe Length 54" Less Soap Dispenser 21-1/2" (546mm) 36" Less Soap Dispenser 18" (457mm) 54" With Soap Dispenser 30" (762mm) 36" With Soap Dispenser 26-1/2" (673mm) 54" Less Soap Dispenser With Towel Dispenser 55-1/2" (1410mm) 36" Less Soap Dispenser With Towel Dispenser 52" (1321mm) 54" With Soap Dispenser With Towel Dispenser 48" (1219mm) 36" With Soap Dispenser With Towel Dispenser 44-1/2" (1130mm) 54" With Cube Adapter 32" (813mm) 36" With Cube Adapter 28-1/2" (724mm) 54" With Cube Adapter With Towel Dispenser 50" (1270mm) 36" With Cube Adapter With Towel Dispenser 46-1/2" (1181mm) 54" With Cube Adapter And Soap Dispenser 40" (1016mm) 36" With Cube Adapter And Soap Dispenser 36-1/2" (927mm) NOTE: Drain must be connected with 2" schedule 40 welded wrought iron pipe, minimum, to provide lower supp...
Dieses Handbuch ist für folgende Modelle:Plumbing - WF2605 (416.5 kb)