Hersteller: Yamaha
Dateigröße: 849.15 kb
Dateiname:
|
Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
SPEAKERS1 1 + - + - + - + - 2 2 -- 32 LOCK Minimum speaker impedance: 8 . When using phone jack SPEAKERS+ - + - + - + - -- 32 LOCK Minimum speaker impedance: 4 . ¦ ¦g 5-way binding post Speakon connector (1) Turn off the POWER switch. (1) Turn off the POWER switch. (2) Remove the cover attachment screws and remove the pro- (2) Insert the Neutrik NL4FC plugs into the Speakon connectective cover from the speaker terminals. tor on the rear of the amplifier, and turn clockwise to lock. Neutrik NL4FC plugs A Screw STEREO or PARALLEL BRIDGE CHANNEL (3) Remove about 15 mm of insulation from the end of each speaker cable, and pass the bare wire through the holes in the appropriate speaker terminals. Tighten the terminals to Neutrik NL4FC plugs securely clamp the wires. Refer to page 9 for speaker 1+ A+ 1– A– 2+ B+ 2– B– 1+ + 1– 2+ – 2– polarities. CHANNEL B 1+ B+ 1– B– Speaker cable Phone jack (1) Turn off the POWER switch. (2) Insert the phone plug into the jack on the rear of the amplifier. * Actual size * 15mm Note to users in the USA: Please use Class 3 wiring. (P7000S, P5000S) Please use Class 2 wiring. (P3500S, P2500S) Be sure that the bare wire ends do not jut out from the terminals and touch the chassis. The following shows how the cable should look when correctly attached. ChassisBare wire (4) Reattach the protective cover over the speaker terminals. 11 Rack Mounting Mounting in a standard EIA rack If you are mounting multiple power amplifiers in a rack, be sure to install ventilation panel(s) as shown below. Also be sure to use metal brackets (one on each side) to support the rear of each amplifer. Note: EIA stands for Electronic Industries Alliance. Ventilation panel(s) Use 1U-size blank panel(s). If mounting up to four amplifiers in an open-backed rack Install a ventilation panel as shown below. When mounting five or more amplifiers in an open-backed rack, and when mounting any number of amplifiers in a close-backed rack Install ventilation panels above and below each amplifier, as shown below. 480 44 Unit: mm Ventilation panel (Attach to the front or rear of the rack.) Specification s ¦ General Specifications P7000S P5000S P3500S P2500S Power Output Level (Rated Power) 1 kHz THD + N = 1% 8 ./STEREO 4 ./STEREO 8 ./BRIDGE 750 W . 2 1100 W . 2 2200 W . 1 525 W . 2 750 W . 2 1500 W . 1 390 W . 2 590 W . 2 1180 W . 1 275 W . 2 390 W . 2 780 W . 1 20 Hz – 20 kHz THD + N = 0.1% 8 ./STEREO 4 ./STEREO 8 ./BRIDGE 700 W . 2 650 W . 2 (European Model) 950 W . 2 1900 W . 1 500 W . 2 700 W . 2 1400 W . 1 350 W . 2 450 W . 2 900 W . 1 250 W . 2 310 W . 2 620 W . 1 1 kHz 20 ms non-clip 2 ./STEREO 4 ./BRIDGE 1600 W . 2 3200 W . 1 1300 W . 2 2600 W . 1 1000 W . 2 2000 W . 1 650 W . 2 1300 W . 1 Power Bandwidth Half Power 10 Hz – 40 kHz (THD + N = 0.5 %) Total Harmonic Distortion (THD + N) 20 Hz – 20 kHz, Half Power 4 . – 8 ./STEREO 8 ./BRIDGE 0.1 % . Frequency Response RL = 8 ., Po = 1 W 20 Hz – 50 kHz +0 dB, –1.5 dB Intermodulation Distortion (IMD) 60 Hz:7 kHz, 4:1, Half Power 4 . – 8 ./STEREO 8 ./BRIDGE 0.1 % . Channel Separation Vol. max Half Power RL = 8 . 1 kHz input 600 . shunt 70 dB . Residual Noise Vol. min. 20 Hz – 20 kHz (DIN AUDIO) –70 dBu. SN Ratio 20 Hz – 20 kHz (DIN AUDIO) 104 dB 103 dB 102 dB 100 dB Damping Factor RL = 8 ., 1 kHz 350. 200. Input Sensitivity RL = 8 . (1 kHz, THD + N = 1 %) +8.0 dBu +6.4 dBu +5.2 dBu +3.6 dBu Voltage Gain RL = 8 . 32 dB Input Impedance 30 k./balanced, 15 k./unbalanced Controls Front Panel Rear Panel POWER switch (Push on/Push off) Two 31-step Volume control knobs (one per ch) MODE switch (STEREO/PARALLEL/BRIDGE) Two FILTER switches (SUBWOOFER/LOW CUT/OFF) Two fc knobs (25 to 150 Hz, 12 dB/octave) YS Processing switch (ON/OFF) Connectors INPUT OUTPUT XLR-3-31 jacks (one per ch) 1/4-inch TRS phone jacks (one per ch) Speakon jacks (one per ch) 5-way binding posts 1/4-inch phone jacks (one per ch) Indicators POWER PROTECTION TEMP CLIP SIGNAL YS Processing . 1 (Green) . 1 (Red) . 1 (Red) (heatsink temp 85°C) . 2 (Red) . 2 (Green) . 1 (Yellow) . Load Protection POWER switch ON/OFF muting DC-fault power supply shutdown DC detection Amp. Protection Temp. detection (heat sink temp 90°C), VI limiter (RL 1 .). . Limiter Comp: THD 0.5 %. Cooling Dual variable-speed fan Single variable-speed fan Power Requirements 1...
Dieses Handbuch ist für folgende Modelle:Receiver und Verstärker - P3500S (849.15 kb)
Receiver und Verstärker - P5000S (849.15 kb)
Receiver und Verstärker - P7000S (849.15 kb)
- ()