Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung Philips, modell SDW1850/17

Hersteller: Philips
Dateigröße: 3.18 mb
Dateiname:
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Antenna discharge units (or Lightning Arrestors) should be located outside the building or inside the building between the point of entrance of the lead-in and the TV, and as near as practical to the entrance of the conductors to the building. Product Description The rotator is designed to turn and accurately position even large antennas, allowing best possible reception. Rotation of the rotator unit is synchronized with commands from the indoor control unit to automatically go to up to 12 different memorized positions or any direction chosen manually. The connecting cable between the control unit and the rotator unit carries only safe, low voltage power.When the operating command sequence is finished, the unit shuts off automatically and draws no current until activated by a remote or manual command to the control unit. 3 EN Operation and Installation EN Operation and Installation Fig. 1 Fig. 2 Fig. 3 Operating and Installation Instructions T TTI IIP PP– While you are still on the ground and before mounting the rotator unit to the support mast, temporarily connect the rotator unit to the control unit with the control cable and perform the alignment (and basic system check) by following Steps 2 and 5 and 8 below. Step 1 - Rotator Unit Mounting If not mounting the rotator unit inside a tower, attach the the rotator unit to the support mast by loosening the nuts enough to slide the clamps over the mast. Lower the rotator unit until the cast nose of the drive housing sits on top of the support mast and tighten the nuts. Moderate tightening of the nuts with a 7/16” wrench will cause the teeth of the clamp to grip the mast securely. DO NOT over-tighten to the point that you deform the mast, as this will reduce its strength. Mast Diameters of 1 1/4” to 2” (3-5cm) may be used.The 1 1/2” (3.8 cm) size or larger is recommended for un-guyed mast over 6’ long or where large antennas are used. If guy wires are used, fasten two through each of the two holes of the lower clamp. Step 2 - Rotator Unit (Rotator) Connection Up to 280’ of 20 AWG 3 conductor cable may be used. For longer runs use heavier gauge wire. To attach cable to rotator unit, open the bottom cover using a screwdriver. Remove the grommet and insert the cable through the slot. Press the grommet back into the slot. Separate leads 1 1/4” and strip off 1/2” insulation. Find the silver (or wide jacketed lead) and connect it to terminal 1. Connect the adjacent lead to terminal 2 and the next lead to terminal 3. If 4 wire cable is used connect both wire 3 and 4 to terminal 3. Make sure there are no loose strands which can short between terminals. Recheck the wiring order and then securely close the bottom cover. To avoid moisture collecting in the cable, be sure the jacket passes through the grommet. Step 3 -Antenna Mast Antennas should be mounted as close as possible to the rotator unit. Cut 1-1/4” – 1-1/2” mast to a length not exceeding that shown in the chart below and mount the antenna at the top of the mast. Be sure to attach transmission line to antenna. • Small - Up to 5’ (1.5M) Long 5’ (1.5M) • Medium - Up to 8’ (2.4M) Long 3’ (0.9M) • Large - Over to 8’ (2.4M) Long 2’ (0.6M) • Large with braces See Note • Two antennas* 4’ (1.2M) 4 WWaarrrraannttyy EN MEMORYCHANNEL(S)(DEGREES) DIRECTIONABCDEFGHIJKL Limited One-Year Warranty Philips warrants that this product shall be free from defects in material, workmanship and assembly, under normal use, in accordance with the specifications and warnings, for one year from the date of your purchase of this product. This warranty extends only to the original purchaser of the product, and is not transferable. To exercise your rights under this warranty, you must provide proof of purchase in the form of an original sales receipt that shows the product name and the date of purchase. For customer support or to obtain warranty service, please call 919-573-7863. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. Philips’ liability is limited to repair or, at its sole option, replacement of the product. Incidental, special and consequential damages are disclaimed where permitted by law. This warranty gives you specific legal rights. You may also have other rights that vary from state to state. Technical Support Technical Support For technical support send an email with the model number of the product and a detailed description of your problem to: Email: accessorysupport@philips.com ©2006 Accessories Service Center Philips Accessories and Computer Peripherals, Ledgewood, NJ 07852 USA Manufactured in China Printed in China 7 SP Contenido SP Contenido 9 Instrucciones de seguridad 9 Descripcion del producto 10 Instalacion y operacion 14 Garantia limitada por un ano 14 Asistencia Tecnica 8 SPInstrucciones de seguridad SPInstrucciones de seguridad IMPORTANTE LEER ANTES DE INSTALAR LA ADVERTENCIA LA INSTALACION DE ESTE PRODUCTO CERCA DE LINEAS DE FUERZA ES PELIGROSA. PARA SU SEGURIDAD, MANTENGA ESCALERA Y ANTENA LEJOS DE LINEAS DE FU...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien