Login:
Stimmen - 5, Durchschnittliche Bewertung: 4.2 ( )

Anleitung Esoteric, modell D-01

Hersteller: Esoteric
Dateigröße: 411.49 kb
Dateiname: D-01_OM(E).pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


When the unit is on, the ring surrounding the button lights up. B The equipment draws nominal non-operating power from the AC outlet with its POWER switch in the OFF position. WORD Use this button to switch between word sync modes. A mode indicator lights up to show the current mode (blue indicators showing normal modes, and a purple indicator showing the 4% down mode). The indicator blinks when no usable word sync signal is detected. No indicator lights when word sync is not being used. OUT Lets the unit internally generate and send out Word Clock so the unit acts as a master. IN This mode provides a stable sync operation with most general external clocks. There are occasions when sync is not achieved depending on the output accuracy of the devices in use. This is because the word clock input frequency range of this unit is set to as narrow as ±15ppm, a requirement in order to achieve a sync of high accuracy. Rb IN This is a mode designed for external clocks of a higher degree of precision like a rubidium clock generator. Select this mode when this unit is connected to the ESOTERIC G-0s. Keep in mind that it will take time before the sync is achieved in this mode. This mode requires an even narrow bandwidth of accuracy to lock. Switch the mode to IN when “WRD UNLOCK” or “WRD ERROR!” is shown. Off (tuned off) The unit does not use any word sync. 4% down mode Pressing and holding this button for more than 3 seconds switches the unit back and forth between 4% down and normal modes. < Selecting IN or Rb IN modes achieves sync by using an external clock as master. When in those modes, the word clock fed into the WORD SYNC IN terminal is directly sent out through the WORD SYNC OUT terminal. < This unit readily accepts a maximum 196 kHz clock and automatically switches itself to the incoming signal. < When selecting IN or Rb IN modes, the corresponding indicator blinks and searches for an external clock. When the unit detects a clock and locks to it, the indicator lights steadily (blue) to show that the unit is ready for play. < Make connections to the WORD SYNC terminals prior to powering on the unit. Names of Each Control 2 Names of Each Control 2 CBA D FE Display C D FILTER This button selects algorithms for upward conversion. Pressing the button repeatedly rotates the selection through the following (a lit indicator shows the current selection): FIR RDOT FIR+RDOT DF OFF (Digital Filter OFF) RDOT A fluency digital filter that does upward sample rate conversion. This filter has a slow roll-off characteristic and provides a smooth immersive sound. A maximum 16 times up-conversion is available. FIR An FIR-type digital filter that does upward sample rate conversion. This filter has a sharp roll-off characteristic and provides deep, well-defined sound. A maximum 8 times up- conversion is available. FIR+RDOT This provides a combined function of FIR and RDOT filters. The two up-conversion filters are directly coupled digitally so that the best of each is brought out. Pressing and holding the FILTER button for more than 3 seconds shifts the unit to the setting mode (page 12). INPUT select switch Use this switch to select digital inputs. Select which input your external digital device is connected. The corresponding indicator lights. It blinks when you select an input to which no device is connected or a device that is connected but either turned off or not compatible with the input type. E F OUTPUT This button allows you to adjust the output level in 0.5 dB steps between –99.5 and +6 dB. You can also set the level to –.. When using this feature, switch off the VOLUME BYPASS. VOLUME BYPASS Pressing and holding this button for more than 3 seconds switches the Volume Bypass on and off. On By-passes the volume (output level) circuit. Switch the Volume Bypass on when you will be adjusting the volume using a connected preamplifier. The indicator lights up. Off Switch the Volume Bypass off when this unit is directly connected to your power amplifier and you will use the OUTPUT button to adjust the output level. The indicator turns off. There is danger a sudden excessively loud signal will damage the speakers if you switch the Volume Bypass on while in the process of playing a CD or other media. Be sure to reduce the preamp’s volume before you switch the Volume Bypass on. First Thing To Do First Thing To Do Basic Operation Before anything else, you must select a channel for this unit when you use it for the first time or when you have reset it back to factory settings. 1 Press the POWER button to turn the unit on. When the unit is on, the ring surrounding the button lights up. “CH_SEL>” appears on the left side of the display. On the right side, “L R” and channel icons alternately appear. 2 Press the OUTPUT button (+/–) to select a channel. Repeatedly press the button until the channel you want to select appears on the display. 3 Press the INPUT button to confirm the entry. If you want to change the channel setting, refer to ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien