Anleitung Zusammenfassung


D Install Guide Installation Do the following to install the MIL-120A: 1. Attach a UTP cable from the network to the MIL-120A's RJ-45 port 2. Attach a T-type BNC connector from the network cabling to the BNC connector 3. Connect the power adapter's cord from the power source to the unit Note: Use shielded twisted pair (CAT 5) cabling for CISPR 22 B installation. Link Test The MIL-120A provides a Link test function, which is a 10BASE-T standard. The MIL-120A ships with the Link function test “enabled”—only pin one jumpered with a jumper block. This allows the LEDs to illuminate when there are links. Disabling Link To disable the Link test: 1. Use a Phillips-head screwdriver to remove the four Phillips-type screws located on the sides of the unit 2. Remove the BNC nut and its washer 3. Slide the housing off, over the BNC connector 4. Locate the two-pin Link jumper (Figure 1) 5. Place the jumper block onto both pins 6. Reassemble the unit (reverse steps 1 through 3) Note: The MIL-120A operates in a “StarLAN-10” environment when Link is disabled. Only the Power and Link LEDs Illuminate. Link Test Enabled 1 2 DIP Switch LINK Figure 1.Link and DIP Switch Locations Model: MIL-120A Install Guide Diagnostic LEDs COL/TP: Collisions are occurring on the 10BASE-T network RCV/TP Unit is receiving packets from the 10BASE-T network Link: There is an active connection to a10BASE-T hub (or another node) when Link is enabled Power: Unit is receiving power RCV/CX Unit is receiving packets from the 10BASE2 network COL/CX: Collisions are occurring on the 10BASE2 network Configuration Next to the COAX cable connector, there is a DIP switch that control the 50 ohm termination resistor (Figure 1). These switches support a variety of configurations. Both switches are shipped in the UP position (default). Other configurations include: If the MIL-120A is connected to the end of a multi-node segment without a T- connector and terminator, enable the 50 ohm resistor by: • Placing switch 1: UP and • Placing switch 2: DOWN If the MIL-120A is connected to a single-node “without” a T-type connector and terminator on a COAX cable of less than one meter’s length: • Place both switches (1 and 2) in the DOWN position Note: For this configuration, you do not need a 50 ohm terminator on the COAX segment of the MIL-120A's BNC connector. RJ-45 Pinouts MDI Pin 1=TX+ Pin 2=TX- Pin 3=RX+ Figure 2. RJ-45 Pinouts Pin 6=RX- Follow these guidelines when connecting the 10BASE-T Port: • For a Hub or a Repeater, use a straight-through cable (where the pins are connected 1 to 1, 2 to 2, 3 to 3, and 6 to 6) • For a Workstation/PC port, use a swap cable (where the pins are connected 1 to 3, 2 to 6, 3 to 1, 6 to 2) 1 2 3 4 5 6 87 Model: MIL-120A Legal Regulatory Approvals • FCC Class A • UL 1950 • CSA 22 No. 950 • EN60950 • CE – EN55022 Class B – EN50082-1 Canadian EMI Notice This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada. European Notice Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the commission of the European Community. Compliance with these directives implies conformity to the following European Norms: • EN55022 (CISPR 22) - Radio Frequency Interference • EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity • EN60950 (IEC950) - Product Safety Five-Year Limited Warranty Digi International warrants to the original consumer or purchaser that each of its products, and all components thereof, will be free from defects in material and/or workmanship for a period of five years from the original factory shipment date. Any warranty hereunder is extended to the original consumer or purchaser and is not assignable. Digi makes no express or implied warranties including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose, except as expressly set forth in this warranty. In no event shall Digi be liable for incidental or consequential damages, costs, or expenses arising out of or in connection with the performance of the product delivered hereunder. Digi will in no case cover damages arising out of the product being used in a negligent fashion or manner. To Contact Digi For prompt response when calling for service information, have the following information ready: • Product serial number and rev. • Date of purchase • Vendor or place of purchase Reach Digi Technical Support at 408/744-2751 Or E-mail at “sun-tech@dgii.com” Address: 1299 Orleans Drive Sunnyvale, CA 94089 Voice: 408/744-2775 Fax: 408/744-2793 E-mail: info@dgii.com Doc #: 75140 Rev. D ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien