Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Lathem, modell PC3500TX

Hersteller: Lathem
Dateigröße: 142.97 kb
Dateiname: bf31a6ae-3d49-4a3e-9171-cf3ff6b346f5.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


You must see your network administrator prior to beginning the installation for this information. Mount the Terminal The PC3500TX is designed to operate indoors. You should use the terminal where the temperature is between 32°-110° F and humidity is less than 95%. You should choose a place where the terminal cannot vibrate. Exposure to outdoor conditions such as rain or snow voids the warranty and can damage the terminal. 4 - PC3500TX Terminal Installation & User’s Guide To install the mounting bracket ¦ Locate a flat wall surface. Make sure you can plug the terminal into a 110VAC wall outlet (220VAC in Europe and other areas), which should be no farther than 4 feet from the terminal. ¦ Place the bottom of the mounting template on the wall 48 inches from the floor and tape the template into place. ¦ Drill the 3 holes noted on the template using a 5/16” drill bit. If wires will be routed through the wall, drill up to a 3/4" hole as indicated on the template. Remove the template. ¦ Insert a wall anchor in each of the 5/16" holes and tap with a hammer until flush with the wall. ¦ Align the mounting bracket with the anchors, (pull wiring through the hole in the middle of the case if wires are being routed from the wall), insert the 3 screws and tighten with a phillips head screwdriver. PC3500TX Terminal Installation & User’s Guide - 5 ¦ If all wiring is not routed from the wall, remove one of the mounting bracket knockouts, so you can run the communication cable and 12VDC power pack cable to the terminal. ¦ Insert the key into the mounting bracket lock and turn the key counter clockwise. ¦ Align the slots on the back of the terminal with the tabs on the top of the mounting bracket. Plug in the power pack and communications cable, then lower the terminal into place. ¦ Turn the key clockwise to lock the terminal in place. 6 - PC3500TX Terminal Installation & User’s Guide CHAPTER 3 Connect the Communication Cable For Ethernet communications, CAT 4 or 5 unshielded twisted pair high-speed data communication cable is recommended. An RJ45 plug should be attached as shown in the diagram below. Once the plug is attached to the cable, unlock and remove the terminal from the mounting bracket. Route the cable through the desired knockout of the mounting plate and plug the RJ45 plug into the Ethernet Communication port as shown below. Typical Ethernet Pin Out Pin 1 --- White / Orange Pin 2 --- Orange Pin 3 --- White / Green Pin 4 --- Blue Pin 5 --- White / Blue Pin 6 --- Green Pin 7 --- White/ Brown Pin 8 --- Brown Ethernet communication port DI-DO Connector Network cable with RJ-45 connector coming from network switch PC3500TX Terminal Installation & User’s Guide - 7 CHAPTER 4 Setup the Terminal You must power up and configure each terminal when you install it. You can do this through the terminal’s test and setup mode. To setup the PC3500TX terminal you must have the following: Terminal IP Address (PC3500TX that you are installing) Host IP Address (PC that is running the Terminal Manager Module) Subnet Mask Gateway (If required for your network) You will have to obtain this information from your Network Administrator. Starting the Test and Setup Mode IMPORTANT! The PC3500TX terminal requires that the Terminal Manager module runs with “TCP/IP Server” enabled. The available tests and setup modes are ¦ Test Mode: Tests the Keypad, Display, Memory, Real Time Terminal and Bar Code reader. ¦ Setup Mode: Sets up communication - IP Address, Host IP Address, Subnet Mask and Gateway. ¦ Network Test: (Not Used) ¦ Battery Test: Checks the terminals optional battery backup (UPS). ¦ DI-DO Test: Checks the Digital Input/Digital Output auxiliary port by performing a loop-back test. ¦ Restart Mode: Resets the Terminal, clears all data from memory and performs a power-up sequence. (This does not clear the terminals Network Settings). The terminal must first go through its “Power - Up Test” before you can start the test / setup mode. 8 - PC3500TX Terminal Installation & User’s Guide To power up the terminal ¦ Set the Test / Use switch to the USE position (toward the modular jacks). ¦ Plug the terminal 12VDC power supply into the power connector. The terminal goes through the power up test, beeps and the lights flash. The display message “TERMINAL LOCKED” remains until you communicate with the terminal from the software. PC3500TX Terminal Installation & User’s Guide - 9 Setup Mode – 177B Firmware (For PayClock Pro 3.355G and earlier) To Setup the PC3500TX’s Ethernet Communications Setup Mode allows you to setup the terminal to communicate through the network with the PayClock “TCP/IP Server”. IMPORTANT! The PC3500TX terminal requires that the Terminal Manager module runs with “TCP/IP Server” enabled. ¦ Locate the Test/Use switch on the back of the terminal. ¦ Slide the switch into the TEST position (away from the modular jacks). ¦ With the “TEST MODE” message in the terminal display, press the CLEAR key five (5) times. The message “RESTART M...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien