Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Oregon Scientific, modell BAR332ESA

Hersteller: Oregon Scientific
Dateigröße: 2.12 mb
Dateiname:
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Do not overcharge the batteries. Bac kup power 1 piece AAA battery In the case when the rechargeable battery is flat or nearly flat or when the solar panel has been detached, the AAA battery can act as backup power supply for the main unit. 1. Remove the battery compartment located at the base of the unit. 2. Insert the battery, matching the polarity. 3. Press RESET after each battery change. Power adaptor (not included) The adaptor powers the unit and can also be used for charging the rechargeable battery. When connected to the main unit, will be displayed. NOTE The main unit and adaptor should not be exposed to wet conditions. No objects filled with liquid, such as vases, should be placed on the main unit and adaptor. Remote sensor This product can work with up to 3 sensors at any one time to capture temperature readings in various locations. To set up the remote sensor: 1. Slide open the battery compartment. 2. Slide channel switch to select a channel (1, 2, 3). Ensure you use a different channel for each sensor. 3. Insert the battery, matching the polarities. 4. Press RESET after each battery change. 5. Close the battery compartment. 6. Press and hold SEARCH for 2 seconds to initiate a sensor search. NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. The remote sensor reception icon will show the following status: ICONS MEANING Main unit is searching for sensor(s) A sensor channel has been found No sensor found TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 1.5 m (5 ft) and which can shield it from direct sunlight or wet conditions for an accurate reading. 1.5 m (5 ft) cloc k and ca lendar Cloc k recept ion This product is designed to synchronize its clock automatically with a clock signal. BAR332ES: EU: DCF-77 signal: within 1500 km (932 miles) of Frankfurt, Germany. BAR332ESU: UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn, England. BAR332ESA: WWVB-60 signal: within 3200km (2000 miles) of Fort Collins Colorado. To enable / disable clock signal reception: Press and hold to enable or to disable clock signal reception. NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. If signal reception is unsuccessful, place your unit next to a window, press and hold to force another signal search. Clock signal reception indicator: Strong SIGNAL Wea k / NO SIGNAL Manua lly Set Cloc k To set the clock manually, disable the clock signal reception first. 1. Press and hold . 2. Press / to change the settings. 3. Press to confirm. The settings order is: time zone, 12/24 hr format, hour, minute, year, calendar mode (month – day / day – month), month, day and language. BAR332ES / BAR332ESU: Time zone offset sets the clock +/- 23 hours from the received clock signal time. If you have deactivated the clock signal reception, do not set a value for time zone. NOTE If you enter +1 in the time offset setting, this will give you your local time plus one hour. If you are in the US (BAR332ESA) set the clock to: PA for Pacific time MO for Mountain time CE for Central time EA for Eastern time NOTE The language options are English (E), German (D), French (F), Italian (I), Spanish (S) and Russian (R). To select clock display: Press to toggle between clock with seconds, clock with weekday and calendar. alarm To set the alarm: 1. Press and hold to enter alarm setting. 2. Press / to set hour / minute. 3. Press to confirm. indicates alarm is ON. To activate / deactivate alarm: Press . To silence the alarm: • Press SNOOZE to silence it for 8 minutes OR • Press any key to turn the alarm off and activate it again after 24 hours. To display alarm: Press . Temperature To toggle temperature unit: Press °C / °F. To toggle between each outdoor sensor’s readings: • Press repeatedly OR • Press and hold for 2 seconds to initiate auto toggle of outdoor channels. wEATHER fORECAST This product forecasts the next 12 to 24 hours of weather forecast within a 30-50 km (19-31 mile) radius. Sunny Partially cloudy Cloudy Rainy Snowy bac klight Press SNOOZE to activate backlight for 3 seconds. Reset Press RESET to return to the default settings. spec ificat ions Main Unit TYPE DESCRIPTION L x W x H 158 x 87 x 55mm (6.2 x 3.4 x 2.2 in) Weight 280 g (9.88 oz) without battery Signal frequency 433 MHz Power 2 x UM-4 (AAA) rechargeable batteries; 6V AC adaptor (not included) 1 x UM-4 (AAA) battery (for backup) remote sensor (Thn132n) L x W x H 96 x 50 x 22mm (3.78 x 1.97 x 0.87 in) Weight 62 g (2.22 ounces) without battery Transmission range 30 m (98ft) unobstructed Temperature range -20°C to 60°C (-4°F to 140°F) Power 1 x UM-3 (AA) 1.5 V battery precaut ions • Do not subject the unit to excessive force, shock, dust, temperature or humidity • Do not cover the ventilation holes with any items such as newspapers, curtains etc. • Do not immerse the unit in water. If you s...

Dieses Handbuch ist für folgende Modelle:
Time Clocks - BAR332ESU (2.12 mb)
Time Clocks - BAR332ES (2.12 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien