heruntergeladen wurde: 6   Dateigröße: 35 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

(305 mm) long 18 in. (457 mm) long 24 in. (610 mm) long Fits all Graco high pressure spray guns. (Adapters available for other guns) Includes DripLess™ Tip Guard. Order spray tip separately. GUN NOT INCLUDED WARNING Pressure Relief Procedure To reduce the risk of serious bodily injury, including fluid injection, splashing fluid or solvent in the eyes or on the skin, or injury from moving parts or electric shock, follow this procedure whenever you shut off the sprayer, when checking or ser

heruntergeladen wurde: 6   Dateigröße: 35 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

PART NO. DESCRIPTION QTY 1 180-137 NUT, gun 1 2 180-136 ADAPTER, tip 1 3 166-969 WASHER, tip 2 4 220-222 TIP GUARD 1 5 EXTENSION TUBE 218-244 12 in. for Model 223-390 1 218-245 18 in. for Model 223-391 1 218-246 24 in. for Model 223-392 1 GUN NOT INCLUDED ACCESSORIES Must be purchased separately. SPRAY GUNS Includes Reverse-A-Clean IV DripLess™ Tip Guard and a SwitchTip™ “SILVER” GUN 220-954 5000 psi (350 bar) Max. Working Pressure SwitchTip ™ is size 517. “CONTRACTOR” GUN 220-95

heruntergeladen wurde: 0   Dateigröße: 35 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

Now clear the tip or hose. -WARNING- Hazard of Using Fluids Containing Halogenated Hydrocarbons Never use 1,1, 1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in this equipment. Such use could result in a serious chemical reaction, with the possibility of explosion, which could cause death, serious bodily injury and/or substantial property damage. Consult your fluid suppliers to ensure that the fluids being used are compatible

heruntergeladen wurde: 0   Dateigröße: 137 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

. Operation Pressure Relief Procedure Using the Gun WARNING INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or dispensing accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: . are instructed to relieve the pressure, . stop dispensing, . check or service any of the syst

heruntergeladen wurde: 4   Dateigröße: 178 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

6. Without the tip installed, start the pump or sprayer and flush it according to the pump or sprayer instructions. Prime the pump or sprayer with the fluid you are going to spray. Continued on the next page. ....... . Installation 7. Follow the Pressure Relief Procedure on page 6. 8. Engage the gun safety ring (20), see Fig. 2, page 6. 9. Unscrew the tip guard (17) and install the spray tip (A) and gasket (16) in the tip guard nut. See Fig. 1, page 4. NOTE: The gun will leak if the tip gasket (

heruntergeladen wurde: 3   Dateigröße: 284 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

Always engage the gun trigger safety when you stop spraying. To relieve air pressure, close the Evenflo regulators and open the bleed-type master air valve. WARNING INJECTION HAZARD If you suspect that the Evenflo system is not properly set, or that pressure is not fully relieved, the system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an

heruntergeladen wurde: 1   Dateigröße: 284 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

Set the right air regulator to 30 psi (2.1 bar). The pump will operate, filling the hose and gun. 8. Adjust the right regulator to the lowest pressure necessary for the desired delivery rate; this varies according to the fluid being pumped and other system characteristics. 9. Release the gun trigger, engage the trigger safety, and install the air cap. 10. Release the trigger safety and trigger the gun. Adjust the left regulator until the fluid is properly atomized. To minimize overspray, use the

heruntergeladen wurde: 0   Dateigröße: 332 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

Be sure the electric power circuit is properly grounded. Be sure your gun is not grounded. Use un$rbunded paint hoses to gun only, and be sure your supply pump and the object you are painting are-grounded. All conductive objects within 10 ft (3 m) of the gun must be electrically grounded. Be sure your installation complies with all applicable local codes. ALWAYS use the lowest pressure possible when flushing and use a grounded metal waste container. When flushing, avoid conductive solvents, if p

heruntergeladen wurde: 0   Dateigröße: 334 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

AUTOMATIC MID-RANGE ELECTROSTATIC AIR SPRAY GUN 7bar (100 psi) MAXIMUM WORKING AIR PRESSURE Part Number 218–745, Series B With 1.2 mm (0.047 in.) spray nozzle and part no. 218–996 air cap assembly U.S. Patent No. 4,290,091; 4,219,865; 4,462,061; 4,497,447; 4,660,774; 4,554,622 U.K. Patent No. 2,140,327B; 2,142,559B; 2,147,158; 2,191,423 Patented 1986, 1987 Canada Brevete 1986, 1987 French Patent No. 84 07942; 84 10234 Italian Patent No. 1,111,380 Japanese Patent No. 86. 07416 GRACO INC. P.O. BOX

heruntergeladen wurde: 0   Dateigröße: 346 kb   Hersteller: Graco Inc.  
Kategorie: Farbspritzpistolen
@name

Pull the adjusting screw (34) out of the valve housing (33). 4. Clean all the parts and inspect them for wear or damage. If replacing the seal (40), unscrew it clockwise and remove it from the adjusting screw. 5. Apply medium grade thread sealant to the small threads on the end of the adjusting screw (34) and install a new seal (left hand thread). 6. When reassembling the fan air valve, lubricate the o-ring (32) and the adjusting screw threads with petroleum jelly. 7. After the retaining rin