Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Graco, modell 3400

Hersteller: Graco
Dateigröße: 1.59 mb
Dateiname: 8ec257c2-2cda-4f9a-9359-58e52d621222.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Box 1441 Minneapolis, MN 55440-1441 Copyright 2005, Graco Inc. is registered to I.S. EN ISO 9001 310813 Rev C Repair GMAX™ 3400 Airless Sprayers Korean patent: 10-0647761 - For Portable Airless Spraying of Architectural Coatings and Paints - 3300 psi (22.8 MPa, 228 bar) Maximum Working Pressure Read all warnings and instructions 248663 . 248664 . . 248665 . 248666 . . 310802 309639 309250 309640 .............. .............. .............. .............. Contents WARNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Drive Housing and Connecting Rod . . . . . . . . . . .8 Pinion Assembly/Clutch Armature/Clamp . . . . . . . 9 ClutchHousing . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Engine. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Pressure Control . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Displacement Pump . . . . . . . . . . . . . . . . . . . . . . . 14 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Manual Conventions WARNING Hazard Symbol WARNING: a potentially hazardous situation which, if not avoided, could result in death or serious injury. Warnings in the instructions usually include a symbol indicating the hazard. Read the general Warnings section for additional safety information. Manual Conventions GMAX 3400Hi-BoySprayers . . . . . . . . . . . . . . . .16 Pinion Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 GMAX 3400Lo-Boy Sprayers . . . . . . . . . . . . . . . .20 Pressure Control/Filter Assembly . . . . . . . . . . . . . 22 Pressure Control Wiring Diagram. . . . . . . . . . . . . 23 Complete Sprayers . . . . . . . . . . . . . . . . . . . . . . . .24 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 GracoStandardWarranty . . . . . . . . . . . . . . . . . . .26 CAUTION CAUTION: a potentially hazardous situation which, if not avoided, may result in property damage or destruction of equipment. Note Additional helpful information. 310813 Rev C Warning Warning The following warnings include general safety information for this equipment. Further product specific warnings may be included in the text where applicable. WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area.Do not fill fuel tank while engine is running or hot; shut off engine and let it cool. Fuel is flammable and can ignite or explode if spilled on hot surface. • Do not fill fuel tank while engine is running or hot; shut off engine and let it cool. Fuel is flammable and can ignite or explode if spilled on hot surface. • When flammable liquid is sprayed or used for flushing or cleaning, keep sprayer at least 20 feet (6 m) away from explosive vapors. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. • Ground equipment and conductive objects in work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate medical attention. • Do not point gun at anyone or at any part of the body. • Do not put your hand over the spray tip. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Do not spray without tip guard and trigger guard installed. • Engage trigger lock when not spraying. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. PRESSURIZED EQUIPMENT HAZARD Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. • Tighten all fluid connections before operating the equipment. • Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien