Login:
Stimmen - 5, Durchschnittliche Bewertung: 4 ( )

Anleitung DeVilbiss, modell COMPACT SB-2-546

Hersteller: DeVilbiss
Dateigröße: 508.55 kb
Dateiname: DevilbissCompConvGrav.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


ALWAYS refer to the coating material suppliers instructions and COSHH sheets before using this equipment. Users must comply with all local and national codes of practice and insurance company requirements governing ventilation, fire precautions, operation and house-keeping of working areas. This equipment, as supplied, is NOT suitable for use with Halogenated Hydrocarbons. Static Electricity can be generated by fluid and/or air passing through hoses, by the spraying process and by cleaning non- conductive parts with cloths. To prevent ignition sources from static discharges, earth continuity must be maintained to the spraygun and other metallic equipment used. It is essential to use conductive air and/or fluid hoses. PERSONAL PROTECTIVE EQUIPMENT Toxic vapors – When sprayed, certain materials may be poisonous, create irritation or be otherwise harmful to health. Always read all labels and safety data sheets for the material before spraying and follow any recommendations. If In Doubt, Contact Your Material Supplier. The use of respiratory protective equipment is recommended at all times. The type of equipment must be compatible with the material being sprayed. Always wear eye protection when spraying or cleaning the spraygun Gloves must be worn when spraying or cleaning the equipment. Training – Personnel should be given adequate training in the safe use of spraying equipment. MISUSE Never aim a spraygun at any part of the body. Never exceed the max. recommended safe working pressure for the equipment. The fitting of non-recommended or non-original spares may create hazards. Before cleaning or maintenance, all pressure must be isolated and relieved from the equipment. The product should be cleaned using a gun washing machine. However, this equipment should not be left inside gun washing machines for prolonged periods of time. NOISE LEVELS The A-weighted sound level of sprayguns may exceed 85 dB (A) depending on the set-up being used. Details of actual noise levels are available on request. It is recommended that ear protection is worn at all times when spraying. OPERATING Spray Equipment using high pressures may be subject to recoil forces. Under certain circumstances, such forces could result in repetitive strain injury to the operator. SB-2-546 Page 3 Patent No. 2372465 (GB) MODEL PART NUMBER PARTS LIST Example: COM-G430-14-02 Aircap Fluid nozzle size (14 = 1.4 mm) 00 = No cup 02 = Gravity cup Ref. No. Description Part Number Qty. Options 1 Air Cap/Retaining ring COM-430 SP-100-430-K 1 +2 Nozzle SP-200S-**-K 1 14, 18, 22 e.g ** =14 =1.4 mm +3 Separator SP-626-K5 5 +4 Packing GTI-445-K2 2 5 Spreader Valve SP-403-K 1 6 Stud and Screw GTI-408-K5 5 7 Needle Adjusting Screw SP-614-K 1 +8 Spring SP-622-K5 1 +9 Needle SP-300S-**-K 1 14, 18, 22 e.g ** =14 =1.4 mm 10 Airvalve housing & seal SP-612-K 1 +11 Spindle 1 12 Trigger SP-617-K 1 13 Connector SP-611-K 1 14 Plug SP-637 1 +16 Air Valve Service Kit SPK-101-K 1 17 Retaining Ring and Seals SPK-102-K 1 +18 Clip, Seal and Pin Kit GTI-428-K5 5 23 Air Valve assembly Tool 1 24 Spanner SPN-5 1 Spraygun Service Kit (parts included marked + ) SPK-401-** 1 14, 18, 22 e.g ** =14 =1.4 mm Page 4 SB-2-546 SPECIFICATION Air supply connection: Universal 1/4" BSP and NPS Maximum static Air inlet pressure: P1 = 12 bar (175 psi) Nominal gun Air inlet pressure with gun triggered: 3 bar (44 psi) Maximum Service temperature: 40°C Gun Weight: 412 g MATERIALS OF CONSTRUCTION Gun body: Anodized Aluminum Nozzle: Stainless Steel Needle: Stainless Steel Fluid Inlet / Fluid Passages: Anodized Aluminum Trigger: Nickel Plated Steel INSTALLATION Important: To ensure that this equipment reaches you in first class condition, protective coatings have been used. Flush the equipment through with a suitable solvent before use. 1. Attach air hose to connector (13). Recommended hose size 8 mm bore. The hose must be conductive and electrical bond from the spraygun to earth should be checked with an ohmeter. A resistance of less than 106 Ohms is recommended. 2. Air supply should be filtered and regulated. 3. Attach Cup assembly (22) by screwing into the Fluid Inlet of the spraygun. Tighten with a wrench. OPERATION 1. Mix coating material to manufacturers instructions. 2. Fill the cup with the required amount of material. Fill to no more than 25mm (1") from the top of the cup. DO NOT OVERFILL. 3. Attach Cup Lid. 4. Turn needle adjusting screw (7) clockwise to prevent movement. 5. Turn spreader valve (5) counterclockwise to fully open. 6. Adjust inlet air pressure (For recommended figures see Specifications) at the gun inlet with the gun triggered. (pressure gauge attachment shown under Accessories is recommended for this). 7. Turn needle adjusting screw counter clockwise until first thread shows. 8. Test spray. If the finish is too dry reduce airflow by reducing air inlet pressure or by the optional Airflow Valve (14). Screw the Adjusting Knob (14) in to reduce pressure. 9. If finish is too wet reduce fl...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien