Login:
Stimmen - 2, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Hitachi, modell 308640

Hersteller: Hitachi
Dateigröße: 364.81 kb
Dateiname: 308640J.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


First choice when includes Rev. H READ AND KEEP FOR REFERENCE. quality counts.. INSTRUCTIONS HIGH PRESSURE AIR-ASSISTED Model AA Plus. Spray Gun 4000 psi (28 MPa, 280 bar) Maximum Working Fluid Pressure 100 psi (0.7 MPa, 7 bar) Maximum Working Air Pressure Part No. 238402, Series A Spray Gun with standard spray tip, tip guard, air cap, and 1/4–18 npsm (R1/4–19) air line fitting. Part No. 238851, Series B Spray Gun with AA Reverse-A-Clean (RAC) assembly and 1/4–18 npsm (R1/4–19) air line fitting. Part No. 238852, Series A Spray Gun with standard spray tip, tip guard, air cap, and quick-disconnect air line fitting. Part No. 238883, Series A Hi-Flow Spray Gun with Hi-Flow fluid needle and diffuser-seat, and standard spray tip, tip guard, air cap, and 1/4–18 npsm (R1/4–19) air line fitting. Part No. 239001, Series B Hi-Flow Spray Gun with Hi-Flow fluid needle and diffuser-seat, AA Reverse-A-Clean (RAC) assembly, and 1/4–18 npsm (R1/4–19) air line fitting. 05985 Part No. 238402 Spray Gun shown Part No. 241070, Series A HVLP Spray Gun with standard spray tip, HVLP air cap, and 1/4–18 npsm (R1/4–19) air line fitting. U.S. Patent Nos. 3,843,052; 4,386,739; 5,285,965 United Kingdom Patent No. 2 111 406 B Patented 1984 Canada Brevete 1984 French Patent No. 82–21202 Patents Pending Foreign Patents Pending GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 ..COPYRIGHT 1996, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001 Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 General Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 14 Spray Pattern Troubleshooting . . . . . . . . . . . . . . . . . . 15 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Spray Tip Selection Chart . . . . . . . . . . . . . . . . . . . . . . 22 Air Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Graco Phone Number . . . . . . . . . . . . . . . . . . . . . . . . . . 28 WARNING INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury. . Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medical attention. . Do not point the spray gun at anyone or at any part of the body. . Do not put hand or fingers over the spray tip. . Do not stop or deflect fluid leaks with your hand, body, glove, or rag. . Do not “blow back” fluid; this is not an air spray gun. . Always have the tip guard on the spray gun when spraying. . Check the gun diffuser operation weekly. . Be sure the gun trigger safety operates before spraying. . Lock the gun trigger safety when you stop spraying. . Follow the Pressure Relief Procedure on page 7 whenever you: are instructed to relieve pressure; stop spraying; clean, check, or service the equipment; or install or clean the spray tip. . Tighten all the fluid connections before operating the equipment. . Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately. Permanently coupled hoses cannot be repaired; replace the entire hose. TOXIC FLUID HAZARD Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled. . Know the specific hazards of the fluid you are using. Read the fluid manufacturer’s warnings. . Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines. . Wear the appropriate protective clothing, gloves, eyewear and respirator. RECOIL HAZARD Due to the very high pressure fluid emitted, a strong recoil action will occur when you trigger this gun. If you are unprepared, your hand could be forced back toward your body or you could lose your balance and fall, resulting in serious injury. 2 308640 WARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in serious injury. . This equipment is for professional use only. . Read all instruction manuals, tags, and labels before operating the equipment. . Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distribu...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien