|
Anleitung Zusammenfassung
INDUSTRIES LTD. 18 1100MD OWNERS MANUAL - “B” VERSION recommendations). TROUBLESHOOTING SITUATION POSSIBLE CAUSE (REMEDY) FLUID BEING SPRAYED OUT OF TIP PULSATES, SPRAY HOSE LIES QUIET WHEN GUN TRIGGER CLOSED 1. Spray tip worn out or too large. (replace with new tip of correct size. Tip must not exceed a good condition .031 tip ). 2. Paint hose incorrect type. (replace with genuine top quality H.E.R.O. airless spray hose. Steel braided hose is not recommended ). 3. Too short a length of hose. (minimum 50' of airless spray hose is required. Replace or add hose until a minimum of 50' is being used). FLUID BEING SPRAYED OUT OF TIP PULSATES, SPRAY HOSE CONTINUES TO MOVE VIGOROUSLY WHEN GUN TRIGGER CLOSED 1. Outgo valve (ref# 32) assembled incorrectly. (remove the outgo valve and reassemble closely following the instructions on page 22). 2. Outgo valve ball (ref# 36) worn out or jammed. (inspect outgo ball to ensure that it is round and free of nicks or cuts. Inspect for foreign material jamming ball. Inspect seat and cage for wear. Replace parts as required). PUMP SPRAYS WATER OR SOLVENT AT CORRECT PRESSURES, BUT WILL NOT SPRAY PAINT (Check with pressure gauge, see page 15) 1. Air leak in paint intake assembly. (check all fittings and hose clamps in intake assembly for tightness). 2. Air leak in paint intake. (check for cracked or broken intake fittings. Swivel connector, (ref# 11), or elbow,(ref# 13), may be damaged due to over tightening. Look for small black hairline fractures. Replace damaged parts). 3. Partial blockage in paint intake hose, (ref# 7). (clean and remove any blockages from intake hose. Check to insure strainer bag is not clogging intake hose). SPRAY PATTERN IS SPOTTY OR UNEVEN 1. Pressure is too low. (increase pressure slowly until problem is corrected ). 2. Spray material too thick. (thin as recommended by material manufacturer). 3. Plugged: tank screen, intake tube, gun filter or a combination. (inspect and clean or replace as required). 4. Plugged tip. (remove and clean tip). 5. Pump malfunctioning or unsuitable for the material. (refer to other areas of troubleshooting guide and check material requirements vs 1100MD output abilities). EXCESSIVE OVERSPRAY OR FOGGING 1. Pressure too high. (reduce pressure as required). 2. Material too thin. (follow material manufacturers recommendations re-thinning). 3. Tip too large. (reduce tip size). 4. Improper application technique. (refer to proper application techniques on page 9-11). 5. Too windy. (wait for wind to let up). H.E.R.O. INDUSTRIES LTD. 19 1100MD OWNERS MANUAL - “B” VERSION HYDRAPULSE MEMBRANE REPLACEMENT ( REF# 46 - KIT ) 50 46 47 48 49 1-5/16 Inches TOOLS REQUIRED -1/4" Allen wrench -1/2" Open end wrench (2) -4-45-3 (accessory item) -Torque wrench Removal 1. Remove the eight bolts securing the material head (ref# 27) to the hydraulic head (ref# 51). 2. Remove the material head cushion (ref# 28) and replace with the new one supplied. 3. Place a container under pump to catch hydraulic oil. 4. Gently pull hydrapulse membrane to separate it from the hydraulic head. 5. Remove the nut (ref# 50) on the hydrapulse membrane stem in order to separate the hydrapulse membrane from the hydraulic plastic horn (ref# 47), hydrapulse membrane spring (ref# 48), and spring locator (ref# 49). 6. Clean all parts. Assembly 1. Place hydraulic plastic horn over the new hydrapulse membrane. 2. Position the spring in the bore of the plastic horn. 3. Install the spring locator over the hydrapulse membrane stem and into the spring. Thread the jam nut (ref# 50 - new one provided) onto the stem. 4. Tighten the jam nut until a measurement of 1-5/16” is obtained. The measurement is taken from the top of the hydraulic horn (ref# 47) to the top of the spring locator ( ref# 49). See diagram above. 5. Check the assembly. The spring must be positioned in the bore of the plastic horn on one end and over the shoulder of the spring locator on the other end. Any stem material protruding past the nut may be ground off ( stem should be just past flush with nut ) 6. Place the hydrapulse membrane assembly back into the hydraulic head. 7. Re-install the material head with the eight bolts. Torque to 30 ft. lbs. 8. Refill hydraulic oil tank and "PURGE" system following instructions on page 16. 9. Prime the pump with solvent or water and bring the pump up to full pressure (approximately 2500 psi.). Run the pump on standby ( not triggering gun ) for about 20 minutes, to “break-in” new membrane. 10. Installation is now complete and the pump is ready for use. H.E.R.O. INDUSTRIES LTD. 20 1100MD OWNERS MANUAL - “B” VERSION REPLACEMENT OF INTAKE SEAT (REF # 18) TOOLS REQUIRED -5/16" Allen wrench -vise -torque wrench -screwdriver 25 24 23 22 21 20 18 17 27 16 1. Remove the four bolts (ref# 14) and pull intake endcap (ref# 16), from the pump. The endcap should separate from the material head (ref# 27), with the ball guide (ref# 23) attached. If the ball guide remains in the material head, pr...
Dieses Handbuch ist für folgende Modelle:Farbspritzpistolen - B series (696.93 kb)