Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Philips, modell M2925A

Hersteller: Philips
Dateigröße: 214.2 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• M3919A - Canvas Tote Bag with room for monitor plus accessories. • M1569A - Belt Fastening Button Pack of 10. • M2208A - 100 Disposable Abdominal Belts 1.3m long, 50mm wide (52” long, 2” wide). 1 box of 50 blue and 50 pink. • 40483A - Ultrasound Transmission Gel 12 x 250 ml bottles, shelf life 24 months maximum, 6 months minimum. • 40483A - 5 Liter Refill Container shelf life 24 months maximum, 6 months minimum. • M1910A - Paper Case of 40 packs thermal recorder paper, 0-100 mmHg IUP scale, 30-240 FHR scale, 1 min (3cm) highlights. Orange (USA). • M1911A - Paper Case of 40 packs thermal recorder paper, 0-100 mmHg IUP scale, plus 0-13 kPa scale, 50-210 FHR scale, no highlighted 3 cm lines. Green (International). 1.The monitor has twins capability built in. To monitor twins you require an additional ultrasound transducer. Purchase additional M1356A. • M1913A - Paper Case of 40 packs thermal recorder paper, 0-100 mmHg IUP scale, 50-210 FHR scale, 1 min (3cm) highlighted lines. Green. Not available in Europe. Associated Products External Recorder (M2925A) The recorder is an external device for printing stored fetal traces, or realtime fetal trace output. It connects to the FM-2 via a standard (IEEE 1284 compliant)) printer cable. FM-2 Viewer Utility Software (M2926A) The monitor can send data to an IBM-compatible PC running Microsoft NT4 or 98. See the specifications section of this data sheet for system requirements. Mounting (M3904A and M3909A) • M3904A - GCX Wallmounting. • M3909A - GCX Rollstand Specifications Monitor (M2922A) Federal Law restricts this device to use by or on the order of a physician.1 Standards Compliance The FM-2 Portable Antepartum Fetal Monitor complies with the requirements of the Medical Device Directive 93/42/EEC and the following safety standards: • EN60601-1/IEC60601-1, EN60601-1-1, EN60101-2-37 • IEC 1157 • IEC 60601-1 • UL2601-1 • CAN/CSA C22.2#601.1-M90 Class II equipment, double insulated Continuous operation Parameter Input Connector Resulting Isolation US BF BF Toco BF BF Electromagnetic Compatibility Complies with EN60601-1-2 Environmental Operating Temp: -10oC to 45oC (50oF to 110oF) Storage Temp: -20oC to 60oC (-29oF to 175oF) Relative Humidity: 20% to 90% non condensing Altitude: 0-3048m (10,000 ft) Dimensions Height: 15.24 cm (6.0 inches) Width: 26.4 cm (10.4 inches) Depth: 13.7 cm (5.4 inches) Weight: 2.27 kg (5lb) Power - Battery Type: Lead acid, rechargeable. Operation: minimum 2-hours fully charged at 10oC, longer at higher temperature. Recharge during Maximum 14 hours full monitoring: recharge during monitoring (typical 11 hours). 1.USA only Recharge without Maximum 8 hours to monitoring: full recharge when no monitoring occurs (typical 4.75 hours). Low power warning: Approximately 30 minutes at 25oC. Power - External Power Supply AC-powered 110-120V~, 50-60Hz, 0.15A or 220-240V~, 50-60Hz, 0.08A Display Backlight: Cold cathode fluorescent Active area: 3.78” x 2.83” (320 x 240 dots) Resolution: 85 dots per inch Contrast: 10:1 Ultrasound < 4mW Isata: BPM range: Paper scale: USA paper: 30-240 BPM, International Paper: 50-210 BPM. Ultrasound processing range: 50-240 BPM. Accuracy: ±1% ±1 BPM. Leakage current: .10 . A @ 264 VAC applied to transducer. Isolation: >4 kV RMS, Type BF applied part. Toco Range: 0-100 relative units Resolution: 1 count Accuracy: ±1% ±1 relative unit Leakage: .10 . A @ 264 VAC applied to transducer Isolation: >4 kV RMS, Type BF applied part Transducers Doppler Ultrasound FHR (M1356A) Weight: 185 g (6.5 oz) Cable length: 2.5m (8ft 2in) Diameter: 75mm (2.95in) Latex free External Toco (M1355A) Transducer Weight: 180 g (6.3 oz) Cable length: 2.5m (8ft 2in) Diameter: 75mm (2.95in) Latex free Remote Event Marker (15249A) Length: 2.8m (9ft 2in) Weight 75g (2.65oz) Latex free Reusable Abdominal Belt (M1562A) Length: 1.3m (52in) Width: 50mm (2in) With button holes, and pre-attached buttons. Can be further cut. Contains latex. FM-2 Viewer Utility Software (M2926A) Windows operating system-based utility software. Supplied on CD-ROM, together with operating instructions, license and 3m PC connection cable. System requirements: • IBM-compatible PC (200MHz Pentium or equivalent) • Standard VGA graphics adapter with 8MB memory • CD-ROM drive • 60 MB (minimum) available space on hard drive • Windows 98, or NT (with service pack 6a) operating system Microsoft®, and Windows® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. The FM-2 viewer utility software complies with the requirements of the Medical Device Directive 93/ 42/EEC. Federal Law restricts this devic...

Dieses Handbuch ist für folgende Modelle:
Babyphone - M2922A (214.2 kb)
Babyphone - M2926A (214.2 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien