Hersteller: Panasonic
Dateigröße: 1.52 mb
Dateiname: MCV5330.PDF
|
Anleitung Zusammenfassung
The belt tension is high. Failure to do so could result in personal Injury from agitator releasing quickfy and snapping away. Unplug and turn the unit over. Remove the lower plate as described in the REMOVING/ INSTALLING THE LOWER PLATE section. Remove the agitator, carefully lift it out, and remove the worn or broken belt from the brush pulley and motor shaft. NOTE: The two brush supports may come off along with the two washers as you lift the agitator out. DO NOT lose the two small washers. Loop the new belt around the motor shaft and loop it around the brush pulley. See illustration for correct belt routing. Use only a Panasonic Type UB8 drive belt Before reinserting the agitator make sure the brush supports/washers are on correctly. See illustration in the REPLACING THE AGITATOR section. Install New Belt After checking the brush supports, reinstall the agitator back into the housing grooves. After Installing the agitator, turn it by hand making sure that the belt is not twisted or pinched and all rotating parts turn freely. Replace the lower plate as described In the REMOVING/INSTALLING THE LOWER PLATE section. [CLEANlNGTHEAGITArOR > ' ' ' Switch off the vacuum cleaner and unplug the power cord before cleaning the agitator. In order to keep the cleaning efficiency high, clean the agitator regularly. Remove the lower plate if necessary. See the REMOVING/INSTALLING THE LOWER PLATE section for the proper procedure. Agitator - Cut off any carpet pile and lint entangled around the agitator with a pair of scissors as illustrated. - 14 - 1. When to replace the agitator. The agitator should be replaced when the brushes are worn. Brushes should be checked by holding a card across the lower plate, see illustration. If the bristles on the agitator DO NOT touch the card, you SHOULD replace the agitator for best cleaning results. 2. How to replace the agitator. / Place the vacuum cleaner handle in the upright position. —it/// See the HANDLE ADJUSTMENTS section. Remove the lower plate as outlined in the REMOVING/INSTALLING THE LOWER PLATE section. After the lower plate is removed, carefully lift up the agitator until it clears both sides of the nozzle housing. While holding the agitator up, remove the belt. NOTE: The two brush supports may come off along with the two washers as you lift the agitator out. DO NOT lose the two small washers. Look at the exploded view of the agitator below for correct assembly of the parts. 3. To replace the agitator. Place the bolt over the belt pulley on the brush unit. NOTE: There is a place for the belt to fit on one end of the agitator only. Replace both washers and brush supports, see illustration below for correct assembly. After assembling the belt, washers and brush supports place the agitator back into the nozzle housing by aligning each brush support. After completing the assembly, rotate the brush, turning it by hand to assure that it rotates smoothly and the part is assembled correctly. Replace the lower plate as outlined in the REMOVING/INSTALLING THE LOWER PLATE section. AGITATOR ASSEMBLY Brush Support CLEANING EXTERIOR AND ATTACHMENTS 1. Unplug cord from wall outlet. DO NOT drip water on cleaner. 2. Clean exterior using a clean, soft cloth that has been dipped in a solution of mild liquid detergent and water and wrung dry. Wipe dry after cleaning. 3. To reduce static electricity and dust build-up, wipe outer surface of cleaner and attachments. 4. Wash attachments in warm soapy water, rinse and air dry. DO NOT clean in dishwasher or clothes washer. DO NOT USE ATTACHMENTS IF THEY ARE WET. A CAUTION Attachments used In dirty areas, such as under a refrigerator, shouid not be used on other surfaces until they are washed. They could leave marks. REMOVINGCLOGS The hose located on the back of the vacuum cleaner carries the dirt from the nozzle up to the dust bag. If the hose should become clogged: 1. Unplug the power cord from the outlet before checking the airflow passages. Pull open the suction inlet cover and check for clogging in this area. Hose Cover (Suction Inlet) 2. Disconnect the hose from the short hose and check the hose for clogging. Plug in the vacuum cleaner and turn it on. While running the vacuum cleaner with the hose disconnected, stretch the hose in and out to remove the clog. 3. If the clog still exists, turn the vacuum cleaner OFF and unplug the power cord. Turn the vacuum cleaner over, exposing the underside. Remove the lower plate. Remove the short hose from the housing by lifting it straight up. Inspect the hose end and clear it of any obstructions. Reinstall the short hose and lower plate. See the REMOVING/ INSTALLING THE LOWER PLATE section for detailed instructions. - 16- BEFORE REQUESTING SERVICE A WARNING Electrical Shock or Personal Injury Hazard. Disconnect the electrical supply before servicing or cleaning the unit. Failure to do so could result in electrical shock or personal injury from cleaner sudden...