|
Anleitung Zusammenfassung
Interim Cleaning Method: Machine operates at faster set speed for routine light cleaning. The interim cleaning method will be ineffective if the restorative cleaning method is not performed on a regular basis. 5. Rotate control grips completely forward to begin cleaning (Figure 12). WARNING: Flammable materials or reactive metals can cause explosion or fire. Do not pick up. NOTE: Machine travel speed for the cleaning modes are set speeds. FIG. 12 6. View brush pressure meter while operating. Meter should read center of green zone (Figure 13). If brush height adjustment is required, see ADJUSTING BRUSH HEIGHT. FIG. 13 7. To operate machine in reverse, raise brush lever and pull reverse drive trigger (Figure 14). FIG. 14 8. To stop cleaning, release control grips. Raise brush lever and turn off machine. 9. After cleaning carpet, allow 3 to 4 hours for carpet to dry. Use air movers to reduce drying time. WHILE OPERATING MACHINE WARNING: Flammable materials or reactive metals can cause explosion or fire. Do not pick up. 1. Periodically check for foam buildup in recovery tank (look through clear dome). If excessive foam buildup begins to develop, pour a recommended foam control solution into recovery tank. ATTENTION: Do not allow foam or water beyond “FULL LINE” label, located on standpipe, vacuum motor damage will result. Vacuum motor damage due to foam or water is not covered by warranty. 2. Overlap each pass by about 51 mm (2 in). 3. Keep machine within 152–203 mm (6–8 in) of baseboard. 4. When turning, it may be necessary to turn pump switch off and raise brush lift lever. (Home) Home (Find...) Find... (Go To..) Go To.. (Prev.) Prev. (Next) Next Concorde HP Plus (01–00) OPERATION 5. Before reaching end of cleaning path, turn pump switch off and continue to drive machine forward to extract solution. 6. Drain recovery tank when recovered water reaches “FULL LINE” label, located on standpipe in recovery tank (See DRAINING TANKS). 7. Observe gallon marker for remaining cleaning solution. 8. Periodically check battery meter discharge level. Recharge batteries when discharged below half. 9. When solution tank runs dry, turn off pump and vacuum switches, raise brush and transport machine to draining area (See DRAINING TANKS). 10. If cleaning path leaves streaks, spray tip cleaning is required (See SPRAY BAR AND SPRAY TIP MAINTENANCE). 11. If machine is left unattended, turn off machine and pull out main circuit breaker button. FOR SAFETY: Before leaving or servicing machine, stop on level surface, turn off machine and pull out main circuit breaker button. CIRCUIT BREAKER PANEL The machine is equipped with (3) resetable circuit breakers to protect machine from damage, (labeled as brush, main and drive). They stop current flow when circuit overload occurs. Once a circuit breaker has tripped, determine problem, let motor cool down and manually reset breaker by pressing circuit breaker button. The vacuum motors are thermally protected and will automatically shut–off when an overload occurs. The main and drive circuit breakers are designed so you can stop current flow by manually pulling out circuit breaker buttons. Pull out the main circuit breaker button when servicing machine or when machine is left unattended. Circuit breaker buttons are located at rear of machine as shown (Figure 15). ADJUSTING BRUSH HEIGHT 1. Turn all switches off. FOR SAFETY: Before leaving or servicing machine, stop on level surface, turn off machine and pull out main circuit breaker button. 2. Disengage brush lift lever from lock block (Figure 16). FIG. 16 3. Locate adjustment knobs on adjustment shaft and loosen bottom knob (Figure 17). FIG. 17 4. Turn upper knob clockwise to lower brush and counterclockwise to raise. 5. Tighten down bottom knob after adjusting. FIG. 15 (Home) Home (Find...) Find... (Go To..) Go To.. (Prev.) Prev. (Next) Next Concorde HP Plus (01–00) OPERATION ACCESSORY TOOL SETUP AND OPERATION (OPTION) Machine is equipped with accessory tool hookups. The floor tool accessory enables you to reach areas that machine is unable to, such as alcoves and corners. NOTE:Vacuum area before cleaning. 1. Turn main power switch off. 2. Disconnect vacuum hose from recovery dome and replace with accessory vacuum hose (Figure 18). FIG. 18 3. Connect solution hose to accessory coupler at rear of machine (Figure 19). FIG. 19 4. Connect hoses to accessory tool. 5. Raise brush lift lever and engage lock block. 6. Turn main power, pump and vacuum switches on. 7. Operate accessory tool as normal. WARNING: Flammable materials or reactive metals can cause explosion or fire. Do not pick up. 8. For floor tool cleaning: Begin cleaning at top of area and work backwards toward machine. 9. Place floor tool so bottom of stainless shoes are parallel to floor. Squeeze trigger and apply downward pressure on floor tool head and slowly pull tool backwards using both hands. Release trigger 152 mm (6 in) from end of stroke (Figure 20). FIG. 20 10. Push floor tool...
Dieses Handbuch ist für folgende Modelle:Staubsauger - Concorde 608349 (876.28 kb)
Staubsauger - Concorde 609256 (876.28 kb)
Staubsauger - Concorde HP Plus (876.28 kb)