Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.8 ( )

Anleitung Clarke, modell D18

Hersteller: Clarke
Dateigröße: 386.24 kb
Dateiname: d598e131-f596-428b-ab2e-02b3f46c0d28.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


This machine must be connected to the electrical ground to protect the operator from electrical shock. The machine has an approved power cord with three conductors and a plug with three terminals. Connect the plug to a receptacle that has three holes and is connected to the electrical ground. The green (or green and yellow) conductor in the cord is the ground wire. Never connect this wire to any terminal other than the ground pin terminal. DANGER: Improper connection of the equipment-grounding conductor can result GROUNDING INSTRUCTIONS Grounded Outlet Box Grounding Blade is longest of the three blades Figure 1 in risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician. This machine is for use on a 110 to 120 Volt AC 60 cycle electric circuit. Make sure you have the correct frequency and voltage before connecting the power cord to an outlet. The machine has a plug as shown in figure 1. WARNING: Always use this machine with an AC three-conductor electrical system connected to the electrical ground. Replace any worn, cut or damaged cords. Replace any damaged plugs, receptacles or connector bodies. WARNING: Do not cut, remove, or break the ground terminal. Do not try to fit a three-terminal plug into a receptacle or connector body that does not fit the plug, see your Authorized Clarke Dealer to get an authorized person to make the connection. WARNING: Do not move the machine over an electrical cord. Always lift the cord over the machine. EXTENSION CORDS: Use only an approved extension cord with three conductors, a plug with three terminals and a connector body with three holes. This machine has a power cord with wire size 18 AWG (AWG means American Wire Gauge). WARNING: If you use an extension cord, use an extension cord with minimum wire size 16 AWG. Do not use an extension cord longer than 50 feet. Do not join two extension cords. Clarke® Operator's Manual (EN) -D15 & D18 - 5 ENENGLISH HOW TO ASSEMBLE THE MACHINE To assemble the machine, follow this procedure: 1. Remove the brush housing, vacuum bags, hose, wand, handle assembly, canister housing, and tools from the carton. 2. Remove the canister housing and the brush housing from the plastic bags. 3. Install the canister housing on the brush housing. To install the canister housing, follow this proce- C BA D ENENGLISH HOW TO ASSEMBLE THE MACHINE To assemble the machine, follow this procedure: 1. Remove the brush housing, vacuum bags, hose, wand, handle assembly, canister housing, and tools from the carton. 2. Remove the canister housing and the brush housing from the plastic bags. 3. Install the canister housing on the brush housing. To install the canister housing, follow this proce- C BA D dure: Figure 2 a. Position canister housing over brush housing (see figure 2). b. Align pivot airway (A) and canister support pivot (B) with openings (C and D) in bottom of canister housing (see figure 2). c. Lower canister housing completely onto brush housing until pin clicks into place and latches (see figure 3). 4. Install the handle assembly to the canister housing. To install the handle assembly, follow this procedure: a. Insert handle tube in the upper canister housing (see figure 4). b. Lower handle completely into canister housing until mark on handle tube is below flush (see figure 5, item A). This insures the handle is properly seated. c. Push handle latch into lock position (see figure 5, item B). Figure 3 A B Mark on handle tube. Figure 5 Figure 4 Page -6- Clarke® Operator's Manual (EN) - D14 & D18 ENGLISH EN 5. Install the wand assembly in the right rear canister housing (see figure 6, item A). 6. Position wand handle so that handle is towards the front of the machine (see figure 7, item A). 7. Attach hose to wand and canister (see figure 7). To attach hose properly, depress lock on canister (see figure 7, item B). 8. Snap the crevice (B) and upholstery (C) tools into the tool retainer on rear of canister housing (see figure 6). A B C Figure 6 A B B Figure 7 Clarke® Operator's Manual (EN) -D15 & D18 - 7 ENENGLISH THE CONTROLS ENENGLISH THE CONTROLS The Handle Release Pedal (See figure 8, item A) The handle release pedal is on the lower left side of the machine. Press the pedal to release the handle and start the brush motor. The brush motor will not run unless the ON/OFF switch is in the "I" position. The ON/OFF Switch (See figure 9) The ON/OFF switch is on handle. Put the switch in the "I" position to start the vacuum motor. Put the switch in the "O" position to stop the vacuum motor. Putting the switch in the off position will also shut off the brush motor. The Height Adjustment (See figure 8, item B) The height adjustment is located on the lower right side of the machine. Press the front of the pedal with your foot when vacuumin...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien