Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Clarke, modell S30

Hersteller: Clarke
Dateigröße: 460.01 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Turn the key switch off or disconnect the power to the battery to apply the brake. There is a mechanical lever located on the brake. This lever is an override. To manually release the brake, rotate the lever clockwise. To return the brake to normal or to apply the brake, rotate the lever up counter clockwise. NOTE: If the lever is left in the override position, the brake will not function with thekey switch, and the machine will not operate. "S" Model - The brake is located to the left hand rear of the machine. Press pedal to activate brake and release pedal to disengage brake. Figure 4 Figure 5 Figure 7 Figure 6 Clarke® Operator's Manual -Encore S30/L30 Page -11 How To Prepare the Machine For Operation How To Install The Batteries The Encore machines uses either two 12-volt batteries or four - 6 volt batteries. The batteries are located in the battery compartment under the recovery tank. To install the batteries, follow this procedure: 1. Turn machine off. Set brake (if equipped). 2. Make sure recovery tank is empty. 3. Tip up the recovery tank until it locks in the full open position. See figure 8A. CAUTION: Before raising the tank, be suretank is empty. NOTE: There is an intermediate position available for holding the recovery tank open for charging batteries. See figure 8B. WARNING: Do not operate or perform maintenance on the machine while the recovery tank is in the intermediateposition. The tank can be accidentally bumped and it may slam shut. 4. Place the batteries in the tray as shown in figure 8C. WARNING: The batteries are heavy. Liftingbatteries without help could result inan injury. Get help to lift the batteries. WARNING: Working with batteries can bedangerous. Always wear eyeprotection and protective clothingwhen working near batteries. NO SMOKING! 5. Connect the cables between batteries and install long battery cable assembly as indicated. See figure 8C. 6. Join the connector from the battery pack to the connector on the control panel. See figure 9. 7. Close recovery tank by pulling up on the latch arm and then slowly lowering the tank. NOTE: Charge the batteries before using the machine. Figure 8A Figure 8B Figure 9 Figure 8C Page -12- Clarke® Operator's Manual -Encore S30/L30 How To Prepare the Machine For Operation How To Prepare the Machine For Operation Battery Maintenance The electrical power to operate the machine comes from the storage batteries. Storage batteries need preventative maintenance. WARNING: Working with batteries can be dangerous. Always wear eye protection and protective clothing when working near batteries. NO SMOKING! To maintain the batteries in good condition, follow these instructions: 1. Keep the electrolyte at the correct level. The correct level is between 1/4" (1/2 cm) below the bottom of the tube in each cell and above the tops of the plates. Check the level of the electrolyte each time you charge the batteries. See figure 10. NOTE: Check the level of electrolyte prior to charging the batteries. Be sure the plates in each cell are covered with electrolyte before charging. Do not top off the cells prior to charging the battery. Electrolyte expands during charging. As a result, the electrolyte could overflow from the cells. Always top off the cells with distilled water after charging. CAUTION: Irreversible damage will occur to the batteries if electrolyte does not cover the plates. Keep the electrolyte at the correct level. CAUTION: Machine damage and discharge across the tops of the batteries can occur if the batteries are over filled. Do not fill the batteries up to the bottom of the tube in each cell. Wipe any acid from the machine or the tops of the batteries. Never add acid to a battery after installation. CAUTION: Batteries must be refilled with distilled water only. Do not use tap water as it may contain contaminants that will damage batteries. 2. Keep the tops of the batteries clean and dry. Keep the terminals and connectors clean. To clean the top of the batteries, use a damp cloth with a weak solution of ammonia or bicarbonate of soda solution. To clean the terminals and connectors, use a terminal and connector cleaning tool. Do not allow ammonia or bicarbonate of soda to get into batteries. Correct Level Figure 10 Figure 11 3. Keep the batteries charged. 4. To drain battery compartment: (See figure 11) a. Always wear protective eye protection and protective clothing. b. Add a weak solution of ammonia or bicarbonate of soda solution to battery compartment to neutralize any spilled acid. c. Pull drain hose out from under transaxle. d. Place hand behind flange and open valve. e. When empty, close valve. f. Replace valve and drain hose on top of transaxle. g. Neutralize any acid spills with ammonia or bicarbonate of soda. Clarke® Operator's Manual -Encore S30/L30 Page -13 How To Prepare the Machine For Operation How To Prepare the Machine For Operation How To Charge The Batteries WARNING: Charging the batteries in an areawithout adequate ventilation could...

Dieses Handbuch ist für folgende Modelle:
Staubsauger - L30 (460.01 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien