Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Linear, modell M&S DMC-10H

Hersteller: Linear
Dateigröße: 1.3 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


POWER CORD PROTECTION Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance. READ INSTRUCTIONS All the safety and operating instructions should be read before the product is operated. RETAIN INSTRUCTIONS The safety and operating instructions should be retained for future reference. HEED WARNINGS All warnings on the product and in the operating instructions should be adhered to. FOLLOW INSTRUCTIONS All operating and use instructions should be followed. ATTACHMENTS Do not use attachments not recommended by the product manufacturer as they may cause hazards. ACCESSORIES Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, causing serious injury to a child or adult, and serious damage to the product. Use only with a cart, stand, tripod, bracket or table recommended by the manufacturer, or sold with the product. Any mounting of the product should follow the manufacturer’s instructions, and should use a mounting accessory recommended by the manufacturer. OVERLOADING Do not overload wall outlets, extension cords, or integral convenience receptacles as this can result in a risk of fire or electric shock. REPLACEMENT PARTS When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards. SAFETY CHECK Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to determine that the product is in proper operating condition. WALL OR CEILING MOUNTING The product should be mounted to a wall or ceiling only as recommended by the manufacturer. HEAT The product should be situated away from heat sources such as radiators, heat registers, stoves, or other products (including amplifiers) that produce heat. 4 Component Features SIGNAL OVERLOAD SIGNAL LEVEL ADJ. MUTE OUTPUT LEFT RIGHT DMC-10AWP AUDIO INPUT POWER CONNECTOR EXPANSION HUB CONNECTOR EXPANSION HUB STATUS INDICATOR MUTE ENABLE SWITCHES DOOR RELEASE ENABLE SWITCHES DOOR RELEASE CONNECTOR STATION STATUS INDICATORS (8) STATION CONNECTORS (8) DMC-10PS PATIO STATION DMC-10H INTERCOM HUB DMC-10RS ROOM STATION DMC-10DS DOOR STATION LISTEN BUTTON TALK BUTTON TALK BUTTON MICROPHONE UNLOCK BUTTON DOOR TALK BUTTON VOLUME CONTROL MUTE BUTTON MICROPHONE DOOR TALK BUTTON VOLUME CONTROL MUTE BUTTON MICROPHONE DOOR CHIME BUTTON DMC-10AWP AUDIO INPUT WALLPLATE SIGNAL LEVEL ADJUSTMENT MUTE OUTPUT AUDIO INPUT JACKS SIGNAL OVERLOAD INDICATOR Figure 2. Station and Hub Features 5 Installation System Design Evaluate the installation to determine locations for mounting the intercom components. The intercom hub mounts in a new or existing structured wiring enclosure. The DMC-10RS room stations can be located in any rooms that require communications. DMC-10PS patio stations are weather resistant and designed to be mounted in protected areas outdoors. DMC-10DS door stations are also weather resistant and typically mounted next to the primary visitor entrance and any other auxiliary entrances. Up to eight stations of any type can be connected to one DMC-10H hub. An additional DMC-10H hub can be connected to the primary hub for expansion, increasing the system capacity to sixteen stations total. Structured Wiring Enclosure Linear’s OpenHouse brand Model H312KIT 12-inch high structured wiring enclosure is recommended for mounting the DMC-10H hub. Other OpenHouse enclosures can also be used to mount the hub. Enclosures mount recessed, between wall studs, or can be surface mounted. Be sure the enclosure is in a location where 117 VAC power can be routed to the enclosure by a licensed electrical contractor for connection to an outlet in the enclosure. Hub Mounting The hub locks into the mounting grid of the structured wiring enclosure the same as other structured wiring modules (see Figure 4). Hook the mounting tabs into the grid, swing the hub into place, and push the locking button to fi nish the hub mounting. MOUNTING GRID AC OUTLET Figure 3. OpenHouse Model H312KIT Structured Wiring Enclosure Figure 4. Hub Mounting in the Enclosure 1 HOOK MODULE INTO GRID 2 SWING MODULE INTO PLACE 3 PUSH BUTTON TO LOCK MODULE INTO GRID 4 MODULE INSTALLED READY FOR HOOK-UP 6 Installation (Continued) Junction Box Installation Each intercom station mounts inside a standard 2-gang J-box. Mount the J-boxes fl ush with the drywall at locations and heights convenient for the installation. System Wiring Route Cat-5 or Cat-5e cable from each station’s J-box to the structured wiring enclosure where the hub will be mounted. Drill through studs and headers to accommodate cabling. Secure the cables with zip-tie straps (be careful not to punctur...

Dieses Handbuch ist für folgende Modelle:
Telefonanlagen - M&S DMC-10DS (1.3 mb)
Telefonanlagen - M&S DMC-10PS (1.3 mb)
Telefonanlagen - M&S DMC-10RS (1.3 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien