Anleitung Aube Technologies, modell CT240
Hersteller: Aube Technologies Dateigröße: 272.54 kb Dateiname: CT240.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
It is possible to command a temperature decrease (Unoccupied) during a prolonged absence or a temperature increase (Comfort) before you return home. Depending on your thermostat’s operating characteristics, it either connects to the Aube output (for most Aube models) or to the auxiliary output. When the auxiliary output is not used to control a thermostat, it can be used to simultaneously control a load such as a water heater, lighting, etc. .. .. Any device connected to a telephone line must conform to the country's standards. The CT240 telephone controller meets: • FCC68 standards for installation on the North American network. • FDTBR21 standards for installation on the European network. • One CT240 telephone controller • One power transformer 120 V (North America) or 250 V (Europe) • One 5 m (16 foot) telephone cable NOTE: If you are using an answering machine, position the answering machine switch to ON before installing the CT240. Make sure that your answering machine answers after a minimum of 4 rings. .. .. .. Mount the CT240 near a telephone outlet. NOTE: If you plan to connect a load having more that 30 volts on the auxiliary output, the CT240 must be installed inside a certified electrical box. .. OPTIONAL. Connect your phone (or answering machine) to the PHONE connector of the CT240. .. Connect one end of the telephone cable to the LINE connector of the CT240 and the other end to the telephone outlet in your home. .. Connect the thermostat and load. Both outputs work simultaneously. NOTE: Refer to your thermostat’s electrical specifications (telephone interface) for the connection requirements. • If your thermostat requires a 12 VDC signal to switch to Vacation setpoint, use the ABC output (FIGURE 4): A and C terminals: • 0 VDC in Comfort mode • 12 VDC in Vacation mode NOTE: 50 mA max. for parallel connection of Aube thermostats. • If your thermostat requires a dry contact to switch to the Vacation setpoint, use the 123 output (FIGURE 5): • Load = terminals 2 and 3 (NC) (open = Vacation) • Thermostat = terminals 1 and 2 (NO) (closed = Vacation) .. When all connections have been made, connect the power transformer to the 9 V outlet of the CT240 and the other end to the wall electrical outlet. The power indicator light is ON when the circuit is powered. .. .. 1 Power Indicator. Indicates the CT240 is powered on. To turn it off, unplug the power transformer. 2 Communication Indicator. Indicates the CT240 has answered and is awaiting a command. 3 Ring Indicator. This indicator flashes when the phone rings. 4 Reset. This button can be used to reset the CT240 to its default values. See section 3.3. 5 Manual Output Activation Button. Can be used to manually switch the relay status. 6 Auxiliary Output. See section 2. 7 12 VDC Output. See section 2. 1/2 400-240-001-A # # NOTE: The CT240 will automatically hang up if no key is pressed during the 30 seconds following the CT240 answering a call. Default values: • Access code = 1234 • Number of rings = 4 . . . . . . . . . """#. $. . % . Dial your phone number Wait for the number of rings... CT240 answers . . """#. $. . . % . Dial your phone number Let it ring once and hang up Wait 10 seconds... Dial your phone number again within the next 30 seconds CT240 answers (1st ring) !'(#)'". #*. Accepted Enter your 4-digit access code (default: 1234) Error #)). ")"+#*,. "). Comfort Press for output status Vacation Press to change status #*,. -. ". #*. Press Enter your new 4-digit access code Accepted Enter the access code again Error #*,. -. !). #. '! ". . . Press Enter the number of rings after x the number of which the CT240 will answer selected rings (between 1 and 9) !. """#. Press to end the session . . #. .. . The button, located on the upper-left corner of the CT240, can be used to manually switch the relay status. This option is not available while the CT240 is answering a telephone call. The light is ON when the auxiliary output is in Vacation mode (terminals 1 and 2 closed) . ' . . /. . . Insert a pointed object (e.g. paper clip) in the hole located under the Reset light. The light will flash 3 times to indicate that the CT240 has been reset: • number of rings: 4 • access code: 1234 • Output status: ABC: Terminals A and C: Comfort 123: Terminals 1 and 2: opened, Terminals 2 and 3: closed " / Power supply: 9 VAC / 60 Hz (50 Hz Europe) Output (ABC): 0 VDC = Comfort mode / 12 VDC = Vacation mode Maximum load for parallel connection of Aube thermostats: 50 mA Auxiliary output (123): SPDT with following capacity: • 5 A / 30 VAC inductive / Power Factor: 0.4 • 10 A / 30 VAC resistive (if installed in a certified electrical box) • 10 A / 240 VAC resistive (if installed in a certified electrical box) • 1/2 HP / 120 VAC motor (if installed in a certified electrical box) • 1 HP / 240 VAC motor (if installed in a certif...