|
Anleitung Zusammenfassung
Note that DUT in the following table refers to the Device Under Test, which in this case is the Grandstream GXP11XX/GXP14XX/GXP21XX/GXV31XX. BroadWorks Device Management Interoperability Test Plan Support Table Test Plan Package Test Plan Package Items Supported Comments HTTP File Download HTTP Download Using XSP IP Address Yes HTTP Download Using XSP FQDN Yes HTTP Download Using XSP Cluster FQDN Yes HTTP Download With Double Slash Yes HTTPS File Download HTTPS Download Using XSP IP Address Yes HTTPS Download Using XSP FQDN Yes HTTPS Download Using Yes GRANDSTREAM GXV31XX/GXP11XX/GXP14XX/GXP21XX SERIES PHONES 20-BD5320-00 ©2011 GRANDSTREAM PAGE 22 OF 46 BroadWorks Device Management Interoperability Test Plan Support Table Test Plan Package File Inspection Device Inspection HTTP File Upload Call Processing Sanity Tests Test Plan Package Items XSP Cluster FQDN Inspect System Config File Inspect Device-Specific Config File Inspect Other Config Files Inspect Static Files Inspect SIP Settings Inspect Line Settings Inspect Service Settings HTTP Upload Using XSP IP Address HTTP Upload Using XSP FQDN HTTP Upload Using XSP Cluster FQDN Register with Authentication Call Origination Call Termination Remote Restart Shared Line Origination Shared Line Termination Shared Line Status Busy Lamp Field Supported NA NA NA NA Yes Yes Yes No No No Yes Yes Yes Yes Yes Yes Yes Yes Comments Config files cannot be retrieved from phone. GXP models only GXP models only GXP models only GXP models only GRANDSTREAM GXV31XX/GXP11XX/GXP14XX/GXP21XX SERIES PHONES 20-BD5320-00 ©2011 GRANDSTREAM PAGE 23 OF 46 5.2 Device Management Configuration This section identifies the steps required to enable the Grandstream GXP11XX/GXP14XX/GXP21XX/GXV31XX for device management. For Device Management configuration information that is not described in this document, see the BroadWorks Device Management Configuration Guide [2]. 5.2.1 Configure BroadWorks Tags The Grandstream GXP11XX/GXP14XX/GXP21XX/GXV31XX makes use of dynamic tags which may be configured by a BroadWorks administrator as either system default or device type specific tags. This section identifies the required tags. 5.2.1.1 Create System Default Tags Browse to System . Resources . Device Management Tag Sets and select the System Default tag set. Add the system default tags in the following table if they do not already exist. Tag Name Valid Settings Description %SBC_ADDRESS% IP address/FQDN SBC SIP address Example System Default Tag settings: Figure 2 System Default Tag Settings GRANDSTREAM GXV31XX/GXP11XX/GXP14XX/GXP21XX SERIES PHONES 20-BD5320-00 ©2011 GRANDSTREAM PAGE 24 OF 46 5.2.1.2 Create Device Type Specific Tags Browse to System . Resources . Device Management Tag Sets and then to add a new tag set, select Add. Configure the tag set name using the device name Grandstream GXP GXV Tags. Add the device type specific tags in the following table to the device tag set. Note that the Grandstream GXP11XX/GXP14XX/GXP21XX/GXV31XX does not currently require device type specific tags, but it is important to create the tag set as a placeholder to enable use of tags in the future. 5.2.2 Configure BroadWorks Device Profile There are two BroadWorks device profile configuration methods described: import and manual. It is necessary to perform only one of the BroadWorks configuration methods. The import method is quick and easy. The manual method walks the administrator through each step. 5.2.2.1 Configuration Method 1: Import This section identifies the steps necessary to make use of the Device Management import feature to configure BroadWorks to add the Grandstream GXP11XX/GXP14XX/GXP21XX/GXV31XX models as Device Management-enabled device types. The import method is available in BroadWorks Release 17.0 and later. For previous releases, use the manual configuration method described in the next section. Download the Grandstream GXP21xx-GXP14xx-GXV31XX CPE kit from BroadSoft Xchange at xchange.broadsoft.com. Extract the DTAF files from the CPE kit. These are the import files. Repeat the following steps for each model you want to import. Log in to BroadWorks as an administrator. Browse to System .Resources • Identity/Device Profile Types and select Import. Select Browse to find the extracted DTAF file for the model and select OK to start the import. After the import finishes, the following post-import configuration steps must be completed. Browse to System . Resources . Identity/Device Profile Types and perform a search to find the imported Grandstream device profile type, (for example, Grandstream GXV3175). Browse to the Profile page and change the Device Management Device Access FQDN to your Xsp or Xsp cluster address. GRANDSTREAM GXV31XX/GXP11XX/GXP14XX/GXP21XX SERIES PHONES 20-BD5320-00 ©2011 GRANDSTREAM PAGE 25 OF 46 Example: Figure 3 Configuration Method 1: Import Firmware files must be obtained from Grandstream. The firmware files are defined for the device profile type but the binaries are not inc...
Dieses Handbuch ist für folgende Modelle:Telefonanlagen - GXP14XX (283 kb)