Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Avaya, modell 200-Type Module Analog

Hersteller: Avaya
Dateigröße: 48.81 kb
Dateiname: 9ea1ccf8-4199-4679-8e72-2045939fc97b.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


All Rights Reserved NOTICE While reasonable efforts were made to ensure that the information in this document was complete and accurate at the time of printing, Avaya Inc. can assume no responsibility for any errors. Changes or corrections to the information contained in this document may be incorporated into future issues. YOUR RESPONSIBILITY FOR YOUR SYSTEM’S SECURITY Avaya Inc. does not warrant that this product is immune from or will prevent unauthorized use of common-carrier telecommunication services or facilities accessed through or connected to it. Avaya Inc. will not be responsible for any charges that result from such unauthorized use. Product administration to prevent unauthorized use is your responsibility and your system manager should read all documents provided with this product to fully understand the features available that may reduce your risk of incurring charges. OBTAINING PRODUCTS To learn more about Avaya Inc. products and to order any of these products, access the Avaya web site at THE “CE” MARK If the “CE” mark is affixed to this equipment, it means that it conforms to the European Union Electromagnetic Compatibility Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC). Overview The 200-type Module Analog Adjunct Interface is an optional device that can be installed with the Avaya 2420 Digital Telephone. This module allows you to connect an analog device (such as an answering machine) to the telephone. NOTE: Disconnect the 2420 telephone from the wall jack and remove power before removing and/or installing the 200-type module. Refer to the 20-Type Stand, 200-Type Module Analog (U.S.) Adjunct Interface, and 201-Type Module Recorder Interface Installation and Safety Instructions (555-233-132) for more information. Requirements The 200-type module requires the installation of the 20-type desk stand. Refer to the 20-Type Stand, 200-Type Module Analog (U.S.) Adjunct Interface, and 201-Type Module Recorder Interface Installation and Safety Instructions (555-233-132) for more information. Switch Settings The 200-type module has two channel setting switches that allow you to specify whether an analog device connected to the 200-type module uses the same line as the 2420 telephone (Channel 1) or separate lines (Channel 2). For more information, refer to the 20-Type Stand, 200-Type Module Analog (U.S.) Adjunct Interface, and 201-Type Module Recorder Interface Installation and Safety Instructions (555-233-132). Troubleshooting Visual Power Indicators The 2420 telephone display provides visual indication whether the module has power. To view the power status, select the Options softkey from the 2420 telephone Home screen, and then select the Self Test feature button. “-” indicates that the module is not receiving power or is not operating properly. “1” indicates that a single module is receiving power and is operating properly. “2” indicates that two modules are receiving power and are operating properly. Resolving Problems If the module is not receiving power or you do not receive dial tone, refer to the following information to resolve the problem. PROBLEM: MODULE DOES NOT HAVE POWER 1Verify that all cords are securely connected at both ends. 2Verify that the line cord connecting the auxiliary supply to the telephone is an 8-wire cord. 3Verify that the 20-type stand is connected to the 2420 telephone. PROBLEM: THE MODULE DOES NOT HAVE DIAL TONE 1Verify that the module has power. (Check the visual indicator on the telephone display.) 2Verify that all cords on the module, the 20-type stand, and the auxiliary power supply are securely connected at both ends. 3Verify that the switches on the module are set correctly. For more information, refer to the 20-Type Stand, 200-Type Module Analog (U.S.) Adjunct Interface, and 201-Type Module Recorder Interface Installation and Safety Instructions (555-233-132). 4Check with your system manager to make certain that the 2420 telephone has been administered correctly. 5Connect the affected module with another 2420 telephone that has a working module. If the module being tested still does not work, it is faulty. If the module being tested works with the other telephone, try the working module taken from the other telephone and connect it to the telephone experiencing the problem. If this module does not work, the telephone is faulty. PROBLEM: THE 2420 TELEPHONE DOES NOT HAVE DIAL TONE 1Make sure the analog equipment attached to your 2420 telephone is on-hook. The analog equipment attached to your 2420 telephone may be off-hook because it does not detect the “disconnect” signal sent from the 200-type module. You must manually turn off (that is, place on-hook) your analog equipment. 2If there is still no dial tone, make sure the handset and line cords at your 2420 telephone are securely connected at both ends. 3If there is still no dial tone, check with your system manager to verify that your telephone is administered correctly. 4If th...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien