Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Furuno, modell FM-8800D/8800S

Hersteller: Furuno
Dateigröße: 4.58 mb
Dateiname: 40544afb-e88c-4693-b79f-a70d6789e633.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


SEP.SEP. 2004 20042004 Printed in Japan Printed in JapanPrinted in Japan A AAll r ll rll ri iig gghts reserved. hts reserved.hts reserved. E EE : :: JUN. JUN.JUN. 15, 15,15, 2006 20062006 Pub. No. Pub. No.Pub. No. IME-56420-E IME-56420-EIME-56420-E * **00014993204 00014993204* ** * **00014993204 0001499320400014993204* ** ( (( TATA TATATATA ) )) FM-8800D/S FM-8800D/SFM-8800D/S * 0 0 0 1 4 9 9 3 2 0 4 * * 0 0 0 1 4 9 9 3 2 0 4 ** 0 0 0 1 4 9 9 3 2 0 4 * * **IME IMEIME56420 5642056420E EE00 0000* ** * **IME IMEIME56420 5642056420E EE00 0000* ** * I M E 5 6 4 2 0 E 0 0 * * I M E 5 6 4 2 0 E 0 0 ** I M E 5 6 4 2 0 E 0 0 * SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS WARNING Hazardous voltage. Can shock, burn or cause serious injury. Do not work inside the equipment unless totally familiar with electrical circuits. Do not approach the antenna closer than 0.9 m (MPE by FCC) when it is transmitting. (MPE: Minimum Permissible Exposure) The antenna emits radio waves which can be harmful to the human body. FM-8800S RF power density on antenna aperture Distance 100 W/m 2 0.11 m 10 W/m2 0.33 m FM-8800D 2 W/m 2 0.9 m 0.11 m Description required by IEC 60945 IEC 60945 MPE by FCC IEC 60945 IEC 60945 MPE by FCC 0.33 m 0.9 m 100 W/m 2 10 W/m2 2 W/m 2 (Text Box comment blank) Turn off the power at the mains switchboard before beginning the installation. Post a warning sign near the switchboard to indicate that power should not be applied while the equipment is being installed. Electrical shock, serious injury or fire can result if the power is not turned off or is applied while the equipment is being installed. CAUTION Attach securely protective earth to the ship's body. The protective earth (grounding) is required to the AC/DC power supply unit to prevent electrical shock. Confirm that the power supply voltage is compatible with the voltage rating of the equipment. Connection to the wrong power supply can cause fire or equipment damage. The voltage rating appears on the label at the rear of the display unit. Observe the compass safe distance to prevent deviation of a magnetic compass. Standard compass Steering compass 1.45 mFM-8800S 0.90 m 1.45 mFM-8800D 0.95 m 0.85 mIF-8810 0.55 m 0.75 mIF-8820 0.50 m 1.50 mHS-2003 0.95 m 0.40 mHS-8800 0.30 m 1.20 mRB-8800 0.80 m 1.50 mRB-8810 1.00 m (W/HS-8800) (W/HS-8800) 0.90 mPR-240-CE 0.60 m TABLE OF CONTENTS SYSTEM CONFIGURATION................................................................................iii EQUIPMENT LISTS ........................................................................................... iv 1. MOUNTING ...................................................................................................1-1 2. CONNECTIONS ............................................................................................2-1 3. ASSEMBLING CONSOLE KIT .....................................................................3-1 PACKING LISTS ............................................................................................... A-1 OUTLINE DRAWINGS ...................................................................................... D-1 INTERCONNECTION DIAGRAMS ....................................................................S-1 SYSTEM CONFIGURATION VHF CH 70 RX Antenna Antenna Transceiver Unit FM-8800D FM-8800S Handset HS-2003 AC/DC Power Supply Unit PR-240-CE 100-115/200-230 VAC Junction Box* IF-8810 Printer PP-510 PP-8800 External Speaker SEM-21Q Wing handset T/R AF output for VDR MAX 2 sets IEC61162-1 input DSC information output External alarm Remote station RB-8800/8810 DMC I/F IF-8820 MAX 4 sets RB-8800/8810 Distress Message Controller DMC-5 Printer IF+UTP-80FK VHF console RC-8800 Omit for Russian Version 50/60 Hz, 1. Radio Battery 24 VDC : Standard 24 VDC : Optional Category of units Unit Category Antenna Exposed to weather All other units Protected from weather *: Option for FM-8800S/D-N EQUIPMENT LISTS Standard Supply Name Type Qty Code No. Remarks 1 Transceiver Unit FM-8800D-E-A 1 — D: Duplex S: Simplex E: With handset HS-2003 F: With microphone DM-2003-F A: With IF-8810 N: No IF-8810 R: Russian version FM-8800D-E-N FM-8800D-F-A FM-8800D-F-N FM-8800S-E-A FM-8800S-E-N FM-8800S-F-A FM-8800S-F-N FM-8800S-R-A FM-8800S-R-N 2 Accessories* FP05-05700 1 000-054-228 For E-type Handset HS-2003, Hanger FP05-05510, Others FP05-05511 FP05-05710 000-054-156 For F-type Microphone DM-2003-F 3 Junction Box IF-8810 1 — For A-type 4 Installation Materials* CP05-09900 1 000-054-227 Power cable 05S9371, CP05-09901 5 Spare Parts* SP05-05501 1 005-377-820 Standard Supply for VHF Console Name Type Qty Code No. Remarks 1 VHF Console RC-8800-SN RC-8800-DN RC-8800-SA RC-8800-DA 1 — D: Duplex FM-8800D S: Simplex DM-8800S N: No printer A: With printer & I/F board 2 Installation Masteries* CP05-10201 1 005-371-850 3 Accessories* FP05-05800 1 000-054-372 Handset HS-2003 & Handset hanger FP05-05510 5 Spare Parts* SP05-05501 1 005-377-820 *: See lists at the end of this manual. EQUIPMENT ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien