Login:
Stimmen - 2, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Barco, modell ICON H250/400 R9010510

Hersteller: Barco
Dateigröße: 7.89 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


An RGB data signal can have its sync signal added in different ways, refer to the Installation section for more information on the RGB+sync signals accepted by the PC input. How to select the PC input ? 1. Press MENU to activate the Tool bar 2. Press v to Pull down the Source Selection menu 3. Use ^ or v to select L3 PC Image 7-6 4. Press ENTER to confirm your choice A bullet indicates the selected composite video source which now appears on the screen. 7.3.6 DVI When The projector is equipped with 2 DVI inputs, one located on the layer 1 and the other on layer 3. Select DVI when in presence of digital data signal connected to a DVI input of the projector. These signals are often available on a PC or other image generator. How to select the DVI input on layer 1 ? 1. Press MENU to activate the Tool bar 2. Press v to Pull down the Source Selection menu 3. Use ^ or v to select L1 DVI Image 7-7 4. Press ENTER to confirm your choice A bullet indicates the selected composite video source which now appears on the screen. R5976992 ICON H250/400 13/12/2006 7.Advanced How to select the DVI input on layer 3? 1. Press MENU to activate the Tool bar 2. Press v to Pull down the Source Selection menu 3. Use ^ or v to select L3 DVI Image 7-8 4. Press ENTER to confirm your choice A bullet indicates the selected composite video source which now appears on the screen. Adjustments on a DVI signal The digital nature of this signal eliminates the need of a large number of adjustments 7.4 General Overview • Pause • Freeze • Identification 7.4.1 Pause Pause The Pause function allows to stop the image display, the projector remaining with full power for immediate restart. The image display is interrupted and the projected background is black. How to pause the image display? 1. Press MENU to activate the Tool bar 2. Press > to select General 3. Press v to Pull down the General menu 4. Use ^ or v to select Pause Image 7-9 5. Press ENTER The projection can also be interrupted using the PAUSE key on the RCU. To restart the image projection press PAUSE R5976992 ICONH250/400 13/12/2006 7.Advanced 7.4.2 Freeze Freezing the image With the Freeze function, the image can be frozen. To restart the image, reuse the Freeze function or press the FREEZE button on the remote. Howto freezethe image? 1. Press MENU to activate the Tool bar 2. Press > to select General 3. Press v to Pull down the General menu 4. Use ^ or v to select Freeze Image 7-10 5. Press ENTER to activate the Freeze function Theimage canalso befrozen using theFREEZEkey on theRCU 7.4.3 Identification The projector’s identification screen The identification screen displays the projector’s main characteristics How to display the identification screen ? 1. Press MENU to activate the Tool bar 2. Press > to select General 3. Press v to Pull down the General menu 4. Use ^ or v to select Identification Image 7-11 5. Press ENTER R5976992 ICON H250/400 13/12/2006 7.Advanced On the screen appears a text box. In this case the projector is an iCon H400 Image 7-12 6. Press MENU or BACK to exit or to go back to the previous menu 7.5 Image Overview • Image settings • Aspect ratio • Color temperature • Film mode detection (video only) • Input balance • Automatic gain control (AGC) • Manual gain control What can be done ? Correct image settings are important for a good image reproduction. The image settings are made through a dialog box with a scroll bar. Minimal, maximal and actual values are indicated. These settings can also be done directly via the RCU’s dedicated buttons, except for the sharpness. All the image settings like contrast can be done in the Image/Settings menu. Image 7-13 7.5.1 Image settings 7.5.1.1 Setting the Contrast Contrast adjustments Adjust the contrast to “brighten” the white parts of the image. R5976992 ICONH250/400 13/12/2006 7.Advanced It is recommended to adjust the brightness before adjusting the contrast. How to change the Contrast 1. Press MENU to activate the Tool bar 2. Press > to select the Image item 3. Press v to Pull down the Image menu 4. Use ^ or v to select settings 5. Press > to pull down the menu 6. Use ^ or v to select Contrast 7. Press ENTER On the screen appears now a slider box Image 7-14 8. Use , the numeric keys on the remote, or the keypad to change the contrast 7.5.1.2 Setting the Brightness Brightness adjustment Adjusting the brightness will affect the dark areas of the image. Increase the brightness to “lighten” up the parts that are too dark. How to change the Brightness 1. Press MENU to activate the Tool bar 2. Press > to select the Image item 3. Press v to Pull down the Image menu 4. Use ^ or v to select settings 5. Press > to pull down the menu 6. Use ^ or v to select Brightness 7. Press ENTER On the screen appears now a slider box Image 7-15 8. Use , the numeric keys on the remote, or the keypad to change the brightness 7.5.1.3 Color Color adjustment Adjust the Color to obtain more or less saturated colors. How to change the Col...

Dieses Handbuch ist für folgende Modelle:
Projektoren - ICON H250/400 R9010500 (7.89 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien