Anleitung Zusammenfassung
Table 2. Replacement Parts Available for the Oxygen Therapy Door Form No. 702703 Rev. E August, 2006 17 Chapter 4 - Repairs and Replacements General Information Parts Ordering Procedure • Many of the threaded fasteners used on SSCI products are secured with thread adhesive to insure structural integrity. Removing any screw or bolt may be difficult at first. • During disassembly, retain all hardware items such as screws, nuts, lockwashers, etc. for reassembly. • If you have problems with any procedure, please feel to call SSCI Customer Support at (800) 323-7366. Order new equipment, accessories and/or replacement parts from your local dealer, or directly through SSCI Customer Service. You can order by mail, telephone or fax. Refer to Contact Information on Page 5 for address, telephone and fax numbers. When ordering, please provide the following information: • Your name • Company name • Company account number • Telephone number • Fax number • e-mail address • Shipping address • Billing address (if different from shipping address) • Names, part numbers, and quantities of items being ordered • Credit card number and expiration date, or other payment information • Preferred method of shipment • Information on whether the items are required on a normal or urgent basis SSCI - Suburban Surgical Company, Inc. Owner’s Manual - Oxygen Therapy Door Procedures Nebulizer Assembly, Complete P/N 212126 This is the complete nebulizer assembly including the bottle, cap, regulator, extension, cotter pin, hose barb fitting and oxygen supply hose (Figure 18). Tool Required • Needle-nose pliers Figure 18. Nebulizer Assembly, Complete Bottle Cap Regulator Hose Barb Fitting Cotter Pin Extension Oxygen Supply Hose Procedure 1. On the nebulizer extension, use a needle-nose pliers to squeeze the two ends of the cotter pin together, then remove the pin from the extension (Figure 19). 2. Open the oxygen therapy door. 3. Place the nebulizer in the ice tray with the extension through the opening in the door (Figures 19 and 20). 4. Inside the door, replace the cotter pin into the extension to hold the nebulizer in place and spread the two cotter pin ends apart to keep the pin from falling out. Form No. 702703 Rev. E August, 2006 19 Chapter 4 - Repairs and Replacements Cotter Pin Extension Opening for Nebulizer Extension Figure 19. Nebulizer Extension and Figure 20. Nebulizer in Place Cotter Pin Nebulizer Assembly, Partial P/N 749510 Nebulizer Oxygen Supply Hose P/N 750492 5. Attach the free end of the nebulizer plastic tubing to a 50 psi wall oxygen outlet or an oxygen cylinder. Note: Your oxygen supplier is the best source to make these connections for you. The partial nebulizer assembly includes the bottle, cap, and regulator (Figure 18). This partial assembly does NOT include the extension, cotter pin, oxygen supply hose, or hose barb fitting. To fit the non-included parts to this assembly, refer to Table 2 on Page 17 for appropriate page references. Note: When ordering a new partial nebulizer assembly, also order a new extension, P/N 754061. The cotter pin, supply hose, and barb fitting can be transferred from your old nebulizer, however, the extension is bonded in place and difficult to remove. This 1/4 in. ID, 3/8 in. OD, 48 in. long tubing (Figure 18) connects the nebulizer to your oxygen source. The source can be a built-in system or an oxygen tank. 1. Push one end of the oxygen supply hose onto the barb fitting on top the bottle (Figure 21). Note:A small amount of grease on the barbs will ease assembly. 2. Attach the free end of the hose to a 50 psi wall oxygen outlet or an oxygen cylinder. Note:Your oxygen supplier is the best source to make these connections for you. SSCI - Suburban Surgical Company, Inc. Owner’s Manual - Oxygen Therapy Door Nebulizer Hose Barb Fitting P/N 854546 Tools Required • 5/8 in. open-end wrench • Utility knife Procedure The hose barb fitting connects the oxygen supply hose to the nebulizer (Figure 21). To replace the fitting: 1. Pull or cut the oxygen supply hose off the fitting. 2. Hold the white, 4-arm knob on top of the regulator, and unscrew the barb fitting with a 5/8 in. open-end wrench. Barb Fitting 5/8 in. Hex 4-arm Knob Oxygen Supply Hose Figure 21. Nebulizer Barb Fitting 3. To install the new fitting, hold the knob and tighten the new fitting with the wrench. 4. Push the oxygen supply hose onto the new fitting. Note:A small amount of grease on the barbs will ease assembly. Form No. 702703 Rev. E August, 2006 21 Chapter 4 - Repairs and Replacements Nebulizer Extension P/N 754061 Nebulizer Cotter Pin P/N 853071 Gauge Assembly P/N 854771 The nebulizer extension is a 2 in. long stainless steel tube that provides a channel for the oxygen from the nebulizer to the interior of the therapy chamber (Figure 18). To mount a new extension to a new nebulizer cap, use a high quality silicone cement. Make sure the finished joint is secure and free of air leaks. The cotter pin holds the nebulizer to the oxy...
Dieses Handbuch ist für folgende Modelle:Andere persönliche Geräte - OXYGEN THERAPY DOOR 12155-00-DRDRAA (1.56 mb)
Andere persönliche Geräte - OXYGEN THERAPY DOOR 12155-00-DREPAA (1.56 mb)
Andere persönliche Geräte - OXYGEN THERAPY DOOR 12155-00-EPDRAA (1.56 mb)
Andere persönliche Geräte - OXYGEN THERAPY DOOR 12155-00-EPEPAA (1.56 mb)