Anleitung Zusammenfassung
It is an electronically operated device that separates oxygen from room air. It provides high concentration of oxygen directly to you through a nasal cannula. Clinical studies have documented that oxygen concentrators are therapeutically equivalent to other types of oxygen delivery systems. Your provider will show you how to use your oxygen concentrator. He/She should be contacted with any questions or problems regarding your oxygen concentrator. This owner’s manual will tell you about your concentrator and will serve as a reference as you use your concentrator. Select a Location You may select a room in your house where using your oxygen concentrator would be most convenient. Your concentrator can be easily rolled from room to room on its casters. Your oxygen concentrator will perform best when operated under the following conditions. Refer to Recommended Guidelines for Optimum Performance on page 17. Usage in environments other than those described may result in the need for increased equipment maintenance. The air intake of the unit should be located in a well ventilated area to avoid airborne pollutants and/or fumes. Perfecto2 ™Series 16 Part No 1143482 SECTION 5—OPERATING INSTRUCTIONS Recommended Guidelines for Optimum Performance Temperature: 50°F - 95°F (10°C - 35°C) Electrical: No extension cords. Placement: No closer than three inches from the wall, furniture, draperies, or similar surfaces. Tubing and Cannula: 7 ft cannula with a maximum 50 ft of Crush-Proof Tubing (DO NOT pinch). Environment: Smoke and soot-free. No confined spaces (Example: No closets). Relative Humidity: 20 to 60% Time of Operation: Up to 24 hours per day. Flow Rate Perfecto2 5: From 0.5 L/min to 5 L/min For flow rates less than 1 L/min, use the Pediatric Flowmeter Accessory. Minimum Operating Time: 30 Minutes NOTE: Ensure that your concentrator is at least three inches away from walls, draperies or furniture to assure sufficient air flow. Avoid deep pile carpets and heaters, radiators or hot air registers. Plug in Power Cord 1. Plug in power cord to an electrical outlet. Part No 1143482 17 Perfecto2 ™Series SECTION 5—OPERATING INSTRUCTIONS Connect Humidifier (If So Prescribed) WARNING For optimum performance, Invacare recommends that each concentrator be on and running for a minimum of 30 minutes at a time. Shorter periods of operation may reduce maximum product life. DO NOT overfill humidifier. DO NOT reverse the oxygen input and output connections. Water from the humidifier bottle will travel through the cannula back to the patient. NOTE: For this procedure, refer to FIGURE 5.1, FIGURE 5.2 on page 19, FIGURE 5.3 on page 20. 1. Remove cap from bottle. 2. Fill humidifier with distilled water to the level indicated by the manufacturer. Replace the humidifier cap and securely tighten. Humidifier Bottle w/o Cap Humidifier Bottle with Cap FIGURE 5.1 Filling the Humidifier 3. Insert a flathead screwdriver in the plate groove on the top edge of the filter access door and gently pry the filter access door off (FIGURE 5.2). 4. Pull up and remove the humidifier bottle adapter (FIGURE 5.2). Perfecto2 ™Series 18 Part No 1143482 SECTION 5—OPERATING INSTRUCTIONS Power Switch NOTE: For this procedure, refer to FIGURE 5.4. 1. Press power switch to on position. All the panel lights and the audible alarm will come on for one second, indicating that the unit is functioning properly. After one second, only the GREEN system ok/power light will stay on. FIGURE 5.4 Power Switch Flowrate NOTE: For this procedure, refer to FIGURE 5.5 on page 22. 1. Turn the flowrate knob to the setting prescribed by your physician or therapist. WARNING DO NOT change the L/min setting on the flowmeter unless a change has been prescribed by your physician or therapist. NOTE: To properly read the flowmeter, locate the prescribed flowrate line on the flowmeter. Next, turn the flow knob until the ball rises to the line. Now, center the ball on the L/min line prescribed. Part No 1143482 21 Perfecto2 ™Series SECTION 5—OPERATING INSTRUCTIONS Perfecto2 ™Series 22 Part No 1143482 2. If the flowrate on the flowmeter ever falls below 0.5 L/min for Perfecto2 5 for more than about one minute, the LOW FLOW alarm will be triggered. This is a rapid beeping of the audible alarm. Check your tubing or accessories for blocked or kinked tubing or a defective humidifier bottle. After rated flow is restored, more than 0.5 L/min for Perfecto2 5 , the LOW FLOW audible alarm will go off. NOTE: The use of some accessories such as the pediatric flowstand and the HomeFill compressor will deactivate the Low Flow Alarm. FIGURE 5.5 Flowrate SensO2 Oxygen Purity Indicator (If Your Unit Features the O2 Sensor Feature) This feature monitors the purity of oxygen generated by the oxygen concentrator. If purity falls below factory preset standards, indicator lights on the control panel will illuminate. Flow Knob Ball Flowmeter Front Panel 0.5 L/min SECTION 5—OPERATING INSTRUCTIONS Initial Startup of the...
Dieses Handbuch ist für folgende Modelle:Andere persönliche Geräte - IRC5P (1.13 mb)