Anleitung TDK, modell NB-59S-09S-0
Hersteller: TDK Dateigröße: 242.36 kb Dateiname: ef441_nb.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. (1/3) Ultrasonic Nebulizer Units Incorporate Type NB Series The TDK ultrasonic humidifier unit was the first such product in the world to be developed. There is an increasing need for indoor humidification due to the proliferation of clean air heat pumps and central heating systems. When the appropriate amount of humidity is added as determined by the relationship between humidity and sensible temperature (temperature perceived by the body), humidification is advanta- ELECTRICAL CHARACTERISTICS geous from the standpoint of both health and reduced energy consumption. In addition to such home uses, these ultrasonic humidifier units have numerous advantages for humidification of vegetable showcases, preservation and growth of agricultural products, industrial applications, etc. A wide variety of standard units are available from TDK. Part No. NB-59S-09S-0 NB-80E-01-H Rated input voltage Eac(V) Edc(V) 48±10% 12±10% Power consumption (W) 30±5 13.2max. Mist output ratio (l/h) 450.10–3min. (150+100, –50).10–3 Ultrasonic frequency (kHz) 1600 to 1750 2350 to 2600 Normal water level (mm) 40 35 External potentiometer (k.) — 10 Operating water temperature range (°C) 0 to 45 0 to 45 Water quality Drinking water Drinking water Transducer element life (h) 10000 5000 Cooling method Water cooled Air cooled Parallel connected operation Yes Yes Weight (g) 60 60 Main application Various humidity control systems Microparticle applications such as for medical use • The character at the end of the product number indicates the transducer’s direction of tilt. EXAMPLE OF ATOMIZATION CHAMBER CONSTRUCTION TYPICAL TRANSDUCER INSTALLATION TYPICAL CHARACTERISTICS OF HUMIDIFIER UNITS VOLTAGE CHARACTERISTICS(48V) WATER TEMPERATURE CHARACTERISTICS(48V) WATER LEVEL CHARACTERISTICS Air-flow Mist Mist discharge tube Atomization chamber Float switch Power transformer Ultrasonic humidifier unitFan moter Transducer Drive circuit Water tank Air-flow . The tilt direction of transtucer will be the same as the direction of water column. The arrows indicate the tilt direction of the transducer. Tilt directions of the transducer NB-59S-09S Type 35 to 45mm(tilted about 7°) 13mm Transducer The direction of water column Transducer ationml)] / hr+40er(gen%)+20550istio(0%=Mrat[Input voltage ratio(%) –30 –20 –10 48V+10 +20 +30 (33.6V) (38.4V) (43.2V) (52. –20 8V) (57.6V) (62.4V) –40 –60 10 20 30 40 50 48V series 24, 12V series Mist output( ml/hr) 700 600 Mist output( ml/hr) 600 400 500 200 30 35 40 45 50 Water temperature(°C) Water level(mm) • All specifications are subject to change without notice. 002-03 / 20120316 / ef441_nb.fm (2/3) NB-59S-09S TYPE NB-80E-01 TYPE FEATURES FEATURES • Compact, with highly reliable circuitry. • Compact, with highly reliable circuitry. • Separate transducer and drive circuit sections provide superior • Separate transducer and drive circuit sections provide superior layout versatility. layout versatility. • Because the ultrasonic frequencies used are higher than with SHAPES AND DIMENSIONS typical household-type units, mist particle size is extremely fine. 1C This part is thus ideal for products intended for smaller spaces. 5 24±0.2 2-o4.520±0.2 22± 0.57± 0.2 54±1 (2-C3) 68 Transistor Aluminum base PCB Driver circuit area 20max. 3max. 42±0.5 4.5max. 9 32±0.2 30± 0.5 Yellow AWG-24 Orange AWG-24 100±10 Supporting rubber Transducer o24± 0.4 Dimensions in mm SHAPES AND DIMENSIONS 43.5max. 18max. 4.5max. 9.5max. o24±0.4 o18±0.3 32±0.2 31.5max. 120±15 TU- 51X- H 4123 2-o4.5±0.2 2-R5.5 2-R15.6 Dimensions in mm 21max. 26max. TYPENB-80E-0163C NO. 65max. 5max. 53±0.2 20.75±0.2 1± 0.2 40± 0.2 2-o3.5 32.5± 0.2 Connector for VR(3 poles) 3022-03A Housing 5224-03CHPB Maker: Molex Connector for power supply(2 poles) 3022-02A 5224-02CHPB • All specifications are subject to change without notice. 002-03 / 20120316 / ef441_nb.fm (3/3) 002-03 / 20120316 / ef441_nb.fm • All specifications are subject to change without notice. MOUNTINGS (Reference) 1.NB59S, NB-80E TYPES The transducer can beak off if the A dimension depth is shallow. TDK recommends a 2mm A-dimension depth and a screw tightening torque of 0.6N•m. 2.CONSTRUCTION OF NB59S The drawing below shows an example method for transistor heat dissipation. The attached aluminum cooling fins should fixed using silicon rubber to a metallic water tank, etc. with sufficient head dissipation capacity. (It is recommended to use a plastic water tank. However, if a metallic water tank is absolutely must be used, be sure to insulate it from the power supply line.) PRECAUTIONS • These units are readily damaged by operation when empty (without water). Therefore a means (float switch, etc.) should be provided to assure operation does not occur when empty. • Con...