The mask-fitting feature delivers air pressure for a three-minute period, prior to starting treatment, for checking and adjusting your mask fit to minimize leaks. To use the mask-fitting feature: 1 Fit your mask as described in the mask user instructions. 2 Hold down ^STAKT/STOpy for at least three seconds until air pressure delivery starts and the following screen appears: Mask-fit star rating The LCD displays a mask-fit star rating from zero to five stars. Three to five stars indicates a good fit or better. Zero to two stars indicates that the mask needs to be adjusted. Reminders on the VPAP LCD Your clinician may have set your VPAP device to remind you about important events, such as when to replace your mask, when to insert your Data Card (if your device is Data Card enabled) and so on. The reminder message is displayed on the LCD and is visible if the device is not delivering therapy. The backlight on the LCD flashes when a message is displayed. Your clinician can set any of the following reminders on your LCD: Message Description Action INSERT CARD May appear if your device is Data Card enabled. Insert your Data Card and follow any instructions that your clinician has given you. When you have done this, the message will disappear from the LCD. Pressing (Ok) will also remove the message. REPLACE MASK Reminds you that your mask is due for replacement. Press (Ok) to remove the message from your LCD and replace your mask with a new one. CALL PROVIDER Reminds you to contact your clinician; for example to discuss your therapy. Press (Ok) to remove the message from your LCD and contact your clinician/service provider. REPLACE FILTER Reminds you to replace the air filter on your device. Press (Ok) to remove the message from your LCD and replace the air filter. SERVICE DUE Reminds you to return your device for service. Press (Ok) to remove the message from your LCD and contact your clinician/service provider. Customized messages Your clinician may also set reminders for other reasons; for example to call a particular person or number. Press (Ok) to remove the message from your LCD and contact your clinician/service provider. 8 Using the Data Card If your clinician needs to review your treatment, they will ask you to use the Data Card to copy data from your VPAP device and return the card to them. Copying Data onto a Data Card 1 Switch on your VPAP and wait until you see the standby (Ramp/Settle) screen. 2 Hold the Data Card with the arrow facing up and insert it into the Data Card slot until it stops. Data copying starts automatically. The "Card Inserted Please Wait" message is displayed on the LCD while data is being copied. Copying takes up to 30 seconds. The "Copy Complete Remove Card" message is displayed on the LCD when copying has finished. 3 Remove the Data Card by gripping the end of the Data Card and pulling it out. 4 Store the Data Card in its protective folder when not in use. 5 Return the card in its protective folder to your clinician using a postal envelope. Updating Settings on your VPAP If your clinician has provided a Data Card with new device settings: 1 With the device in standby (Ramp/Settle) mode, insert the Data Card into the slot on the Data Card module. Updating will start automatically. The "Card Inserted Please Wait" message is displayed on the LCD while updating is in progress. Updating takes approximately five seconds. The "Settings Success Remove Card" message is displayed on the LCD if the settings were updated successfully. Note: This message only appears once. If you re-insert the Data Card after you have updated your settings, this message is not displayed. 2 Remove the Data Card from the VPAP device. 3 Store the Data Card in its protective folder when not in use. ian has told you to use the Data Card to update the settings on your device and the "Settings Success" message does not appear, contact your clinician immediately. Using the VPAP Auto 25, VPAP ST & VPAP S 9 English Traveling with the VPAP Auto 25, VPAP ST & VPAP S International Use Your VPAP flow generator has an internal power adapter that enables it to operate in other countries. It will operate on power supplies of 100-240V and 50-60Hz. No special adjustment is necessary, but you will require an approved power cord for that country. Use on an Aircraft Please consult the medical services department of your carrier if you intend to use your VPAP device on an aircraft. The VPAP Auto 25, VPAP ST and VPAP S comply with US FCC Part 15, Class B requirements if no external data cables are used. Note: You should not use your VPAP device while the aircraft is taking off or landing. Use with DC Power You must use a ResMed DC/DC converter 24V/50W to connect your VPAP to a 12V or 24V DC power source. Contact your equipment supplier or ResMed for details. The device should not be connected to both AC and DC power sources simultaneously. 10 Cleaning and Maintenance You should regu...

Dieses Handbuch ist für folgende Modelle:
Andere persönliche Geräte - VPAP ST (1.23 mb)
Andere persönliche Geräte - VPAP AUTO 25 (1.23 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien