|
Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
If a .1 file already exists, the existing .1 file is destroyed. -In the Event viewer, Adaptec Storage Manager reports both the initial build task for a logical drive and a subsequent Verify/Fix as a "Build/Verify" task. Page 5 ASM_readme_6_10_18451.txt -When displaying information about a physical device, the device, vendor and model information may be displayed incorrectly. -After using a hot spare to successfully rebuild a redundant logical drive, Adaptec Storage Manager will continue to show the drive as a global hot spare. To remove the hot spare designation, delete it in Adaptec Storage Manager. 4. Operating System-Specific Issues and Notes 4.1 Windows - All -The Java Virtual Machine has a problem with the 256-color palette. (The Adaptec Storage Manager display may be distorted or hard to read.) Set the Display Properties Settings to a color mode with greater than 256 colors. -When you shut down Windows, you might see the message "unexpected shutdown". Windows displays this message if the Adaptec Storage Manager Agent fails to exit within 3 seconds. It has no affect on file I/O or other system operations and can be ignored. 4.2 Windows 64-Bit -RAID controllers do not produce an audible alarm on the following 64-bit Windows operating systems: o Windows XP Professional x64 Edition o Windows Server 2003 x64 Edition (all versions) 4.3 Windows Vista Business and Ultimate (64-bit versions) -Flashing a RAID controller on Windows Vista 64-bit systems is not supported in this release of Adaptec Storage Manager. NOTE: Although you can run the image update wizard from Adaptec Storage Manager on a Windows Vista 64-bit system, the wizard does not run to completion. 4.4 Linux -When you delete a logical drive, the operating system can no longer see the last logical drive. WORKAROUND: To allow Linux to see the last logical drive, restart your system. -The controller does not support attached CD drives during OS installation. -On certain versions of Linux, you may see messages concerning font conversion errors. Font configuration under X-Windows is a known JVM problem. It does not affect the proper operation of the Adaptec Storage Manager software. To suppress these messages, add the following line to your .Xdefaults file: stringConversionWarnings: False 4.5 FreeBSD -Due to an issue with the Java JDialog Swing class, the 'Close' button may not appear in Adaptec Storage Manager windows or dialog Page 6 ASM_readme_6_10_18451.txt boxes under FreeBSD. -On FreeBSD systems, JBOD disks created with Adaptec Storage Manager are not immediately available to the OS. You must reboot the system before you can use the JBOD. 4.6 Linux and FreeBSD -If you cannot connect to a local or remote Adaptec Storage Manager installed on a Linux or FreeBSD system, verify that the TCP/IP hosts file is configured properly. 1. Open the /etc/hosts file. NOTE: The following is an example: 127.0.0.1 localhost.localdomain localhost matrix 2. If the hostname of...
Dieses Handbuch ist für folgende Modelle:Andere - Adaptec RAID 5805 (29.25 kb)
Andere - Adaptec RAID 5445Z (29.25 kb)
Andere - Adaptec RAID 5445 (29.25 kb)
Andere - Adaptec RAID 5405Z (29.25 kb)